Biological effects of wear particles generated in total joint replacements: trends and future prospects

被引:16
作者
Suner, S. [1 ]
Tipper, J. L. [2 ]
Emami, N. [1 ]
机构
[1] Lulea Univ Technol, Biotribol Res Grp, Dept Engn Sci & Math, Div Machine Element, Lulea, Sweden
[2] Univ Leeds, Inst Med & Biol Engn, Fac Biol Sci, Leeds, W Yorkshire, England
关键词
Total joint replacements; Wear debris; Metal ions; Biological response; Nanoparticles; Biomaterials; Wear simulation;
D O I
10.1179/1751584X12Y.0000000005
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Joint replacements have considerably improved the quality of life of patients with joints damaged by disease or trauma. However, problems associated with wear particles generated due to the relative motion between the components of the bearing are still present and can lead to the eventual failure of the implant. The biological response to wear debris affects directly the longevity of the prosthesis. The identification of the mechanisms by which cells respond to wear debris and how particles distribute into the human body may provide valuable information for the long term success of artificial joints. During the last few decades, orthopaedic research has been focused on predicting the in vivo performance of joint replacements. However, the exact relationship between material physicochemical properties and inflammatory response has not been fully understood. Laboratory wear simulators provide an accurate prediction of implant wear performance. Though, particles generated from such wear simulators require validation to compare them with particles extracted from peri-implant tissues. This review focuses initially on the current status of total joint replacements (hard on soft and hard on hard bearings) as well as on the tribological behaviour of the potential materials currently under investigation. Then, the correspondence between particles observed in vivo and those generated in vitro to predict the cellular response to wear debris is discussed. Finally, the biological effects of the degradation products generated by wear and corrosion are described.
引用
收藏
页码:39 / 52
页数:14
相关论文
共 165 条
[1]   Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene [J].
Anissian, HL ;
Stark, A ;
Gustafson, A ;
Good, V ;
Clarke, IC .
ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (06) :578-582
[2]   A perspective on nanophase materials for orthopedic implant applications [J].
Balasundaram, Ganesan ;
Webster, Thomas J. .
JOURNAL OF MATERIALS CHEMISTRY, 2006, 16 (38) :3737-3745
[3]   Tantalum-A Bioactive Metal for Implants [J].
Balla, Vamsi Krishna ;
Bose, Susmita ;
Davies, Neal M. ;
Bandyopadhyay, Amit .
JOM, 2010, 62 (07) :61-64
[4]   Femoral Head Size Does Not Affect Ion Values in Metal-on-Metal Total Hips [J].
Bernstein, Mitchell ;
Walsh, Alan ;
Petit, Alain ;
Zukor, David J. ;
Antoniou, John .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (06) :1642-1650
[5]   Implant wear mechanisms-basic approach [J].
Bhatt, Himanshu ;
Goswami, Tarun .
BIOMEDICAL MATERIALS, 2008, 3 (04)
[6]  
Billi Fabrizio, 2009, SAS J, V3, P133, DOI 10.1016/j.esas.2009.11.006
[7]   A new material for hip prosthesis without considerable debris release [J].
Borruto, Adelina .
MEDICAL ENGINEERING & PHYSICS, 2010, 32 (08) :908-913
[8]   What experimental approaches (eg, in vivo, in vitro, tissue retrieval) are effective in investigating the biologic effects of particles? [J].
Bostrom, Mathias ;
O'Keefe, Regis .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2008, 16 :S63-S67
[9]   Intracellular imaging of nanoparticles: Is it an elemental mistake to believe what you see? [J].
Brandenberger, Christina ;
Clift, Martin J. D. ;
Vanhecke, Dimitri ;
Muehlfeld, Christian ;
Stone, Vicki ;
Gehr, Peter ;
Rothen-Rutishauser, Barbara .
PARTICLE AND FIBRE TOXICOLOGY, 2010, 7
[10]   Endotoxin contamination of particles produces misleading inflammatory cytokine responses from macrophages in vitro [J].
Brooks, RA ;
Wimhurst, JA ;
Rushton, N .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (02) :295-299