EPID in vivo dosimetry in RapidArc technique

被引:23
作者
Slosarek, Krzysztof [1 ]
Szlag, Marta [1 ]
Bekman, Barbara [1 ]
Grzadziel, Aleksandra [1 ]
机构
[1] Ctr Oncol Maria Sklodowska Curie, Mem Inst, Branch Gliwice, Radiotherapy & Brachytherapy Planning Dept, Gliwice, Poland
关键词
Arc technique; Portal dosimetry; IMRT; Verification; Electronic portal imaging device;
D O I
10.1016/j.rpor.2010.01.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim: The aim of the study was to estimate the dose at the reference point applying an aSi-EPID device in the course of patient treatment. Materials and methods: The method assumes direct proportionality between EPID signal and dose delivered to the patient reference point during the treatment session. The procedure consists of treatment plan calculation for the actual patient in the arc technique. The plan was realized with an elliptic water-equivalent phantom. An ionization chamber inside the phantom measured the dose delivered to the reference point. Simultaneously, the EPID matrix measured the CU distribution. EPID signal was also registered during patient irradiation with the same treatment plan. The formula for in vivo dose calculation was based on the CU(g) function, EPID signal registered during therapy and the relation between the dose and EPID signal level measured for the phantom. In vivo dose was compared with dose planned with the treatment planning system. Irradiation was performed with a Clinac accelerator by Varian Medical Systems in the RapidArc technique. The Clinac was equipped with an EPID matrix (electronic portal image device) of aSi-1000. Treatment plans were calculated with the Eclipse/Helios system. The phantom was a Scanditronix/Wellhofer Slab phantom, and the ionization chamber was a 0.6 ccm PTW chamber. Results: In vivo dose calculations were performed for five patients. Planned dose at the reference point was 2 Gy for each treatment plan. Mean in vivo dose was in the range of 1.96-2.09. Conclusions: Our method was shown to be appropriate for in vivo dose evaluation in the RapidArc technique. (C) 2009 Wielkopolskie Centrum Onkologii. Published by Elsevier Urban & Partner Sp. z.o.o. All rights reserved.
引用
收藏
页码:8 / 14
页数:7
相关论文
共 19 条
[1]   Intensity-modulated radiotherapy: Current status and issues of interest [J].
Boyer, AL ;
Butler, EB ;
DiPetrillo, TA ;
Engler, MJ ;
Fraass, B ;
Grant, W ;
Ling, CC ;
Low, DA ;
Mackie, TR ;
Mohan, R ;
Purdy, JA ;
Roach, M ;
Rosenman, JG ;
Verhey, LJ ;
Wong, JW ;
Cumberlin, RL ;
Stone, H ;
Palta, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04) :880-914
[2]  
Cozzi L, 2004, MED PHYS, V14, P239
[3]   A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy [J].
Cozzi, Luca ;
Dinshaw, Ketayun Ardeshir ;
Shrivastava, Shyam Kishore ;
Mahantshetty, Umesh ;
Engineer, Reena ;
Deshpande, Deepak Dattatray ;
Jamema, S. V. ;
Vanetti, Eugenio ;
Clivio, Alessandro ;
Nicolini, Giorgia ;
Fogliata, Antonella .
RADIOTHERAPY AND ONCOLOGY, 2008, 89 (02) :180-191
[4]   Relative dosimetry using active matrix flat-panel imager (AMFPI) technology [J].
El-Mohri, Y ;
Antonuk, LE ;
Yorkston, J ;
Jee, KW ;
Maolinbay, M ;
Lam, KL ;
Siewerdsen, JH .
MEDICAL PHYSICS, 1999, 26 (08) :1530-1541
[5]   Intensity modulation with photons for benign intracranial tumours: A planning comparison of volumetric single arc, helical arc and fixed gantry techniques [J].
Fogliata, Antonella ;
Clivio, Alessandro ;
Nicolini, Giorgia ;
Vanetti, Eugenio ;
Cozzi, Luca .
RADIOTHERAPY AND ONCOLOGY, 2008, 89 (03) :254-262
[6]   Correction of pixel sensitivity variation and off-axis response for amorphous silicon EPID dosimetry [J].
Greer, PB .
MEDICAL PHYSICS, 2005, 32 (12) :3558-3568
[7]   Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy [J].
Greer, PB ;
Popescu, CC .
MEDICAL PHYSICS, 2003, 30 (07) :1618-1627
[8]  
Grzadziel A, 2007, REP PRACT ONCOL RADI, V12, P307
[9]   VOLUMETRIC MODULATED ARC RADIOTHERAPY FOR VESTIBULAR SCHWANNOMAS [J].
Lagerwaard, Frank J. ;
Meijer, Otto W. M. ;
van der Hoorn, Elles A. P. ;
Verbakel, Wilko F. A. R. ;
Slotman, Ben J. ;
Senan, Suresh .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (02) :610-615
[10]   Dosimetric investigation and portal dose image prediction using an amorphous silicon electronic portal imaging device [J].
McCurdy, BMC ;
Luchka, K ;
Pistorius, S .
MEDICAL PHYSICS, 2001, 28 (06) :911-924