SIMPLE ANALYSIS OF AMOXICILLIN IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH INTERNAL STANDARDIZATION AND ULTRAVIOLET DETECTION

被引:22
作者
CHARLES, B
CHULAVATNATOL, S
机构
[1] Department of Pharmacy, University of Queensland, Brisbane, Queensland, 4072, Steele Building
关键词
D O I
10.1002/bmc.1130070407
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple high performance liquid chromatographic method with ultraviolet detection at 229 nm is described for quantitation of amoxycillin in plasma. After deproteination of plasma samples with perchloric acid and adjustment of the pH to 4.9, the supernatant was injected onto a reversed phase C18 column, using acetonitrile: phosphate buffer (0.01 M, pH 7.4) (1:25 v/v) as the mobile phase. Amoxycillin and the internal standard, cefadroxil, were eluted at 23 min and 12 min, respectively, without interference from endogenous substances. Processed samples were stable for at least 24 h at room temperature which permitted automated batch processing overnight. Calibration plots of the amoxycillin to cefadroxil peak-height ratio vs. amoxycillin concentration were linear (P<0.0001; r greater-than-or-equal-to 0.995) from 0.25 mg/L to at least 16.0 mg/L. Between-day and within-day imprecision (CV) ranged between 3.7% and 17.7%. Absolute recovery for amoxycillin and cefadroxil exceeded 82%. The application was demonstrated by the analysis of amoxycillin in human plasma after a single oral dose of amoxycillin (250 mg) suspension.
引用
收藏
页码:204 / 207
页数:4
相关论文
共 15 条
[1]   SIMPLIFIED ACCURATE METHOD FOR ANTIBIOTIC ASSAY OF CLINICAL SPECIMENS [J].
BENNETT, JV ;
BRODIE, JL ;
BENNER, EJ ;
KIRBY, WMM .
APPLIED MICROBIOLOGY, 1966, 14 (02) :170-&
[2]   AMOXYCILLIN - REVIEW OF ITS ANTIBACTERIAL AND PHARMACOKINETIC PROPERTIES AND THERAPEUTIC USE [J].
BROGDEN, RN ;
SPEIGHT, TM ;
AVERY, GS .
DRUGS, 1975, 9 (02) :88-140
[3]   DETERMINATION OF AMOXICILLIN IN BODY-FLUIDS BY REVERSED-PHASE LIQUID-CHROMATOGRAPHY COUPLED WITH A POST-COLUMN DERIVATIZATION PROCEDURE [J].
CARLQVIST, J ;
WESTERLUND, D .
JOURNAL OF CHROMATOGRAPHY, 1979, 164 (03) :373-381
[4]   AUTOMATED-DETERMINATION OF AMOXYCILLIN IN BIOLOGICAL-FLUIDS BY COLUMN SWITCHING IN ION-PAIR REVERSED-PHASE LIQUID-CHROMATOGRAPHIC SYSTEMS WITH POST-COLUMN DERIVATIZATION [J].
CARLQVIST, J ;
WESTERLUND, D .
JOURNAL OF CHROMATOGRAPHY, 1985, 344 (NOV) :285-296
[5]   SIMPLE CHEMICAL METHOD FOR ASSAY OF AMOXYCILLIN IN SERUM AND URINE [J].
DAVIDSON, DF .
CLINICA CHIMICA ACTA, 1976, 69 (01) :67-71
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF AMOXICILLIN IN MICROLITER VOLUMES OF CHINCHILLA MIDDLE-EAR EFFUSION AND PLASMA [J].
ERDMANN, GR ;
WALKER, K ;
GIEBINK, GS ;
CANAFAX, DM .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (16) :3339-3350
[7]   ASSAY OF AMOXICILLIN AND CLAVULANIC ACID, THE COMPONENTS OF AUGMENTIN, IN BIOLOGICAL-FLUIDS WITH HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FOULSTONE, M ;
READING, C .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1982, 22 (05) :753-762
[8]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY OF AMPICILLIN, AMOXICILLIN AND CICLACILLIN IN SERUM AND URINE USING A PRE-COLUMN REACTION WITH 1,2,4-TRIAZOLE AND MERCURY(II) CHLORIDE [J].
HAGINAKA, J ;
WAKAI, J .
ANALYST, 1985, 110 (11) :1277-1281
[9]   DETERMINATION OF AMOXYCILLIN IN PLASMA BY ION-PAIR COLUMN EXTRACTION AND REVERSED-PHASE ION-PAIR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
JONKMAN, JHG ;
SCHOENMAKER, R ;
HEMPENIUS, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1985, 3 (04) :359-365
[10]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF AMOXICILLIN IN HUMAN-PLASMA USING A BONDED-PHASE EXTRACTION [J].
LEE, TL ;
BROOKS, MA .
JOURNAL OF CHROMATOGRAPHY, 1984, 306 (MAR) :429-435