Reducing cranial computed tomography effective radiation dose by 30% using adaptive iterative dose reduction

被引:0
作者
Yu, Wai-Yung [1 ]
Ho, Thye Sin [1 ]
Ko, Henry [2 ,3 ,4 ,5 ]
Chan, Wai-Yee [1 ]
Ong, Serene [3 ,4 ]
Hui, Francis Kim Hoong [1 ]
机构
[1] Natl Neurosci Inst, Dept Neuroradiol, Singapore, Singapore
[2] SingHealth, SingHlth Off Res, SingHlth Ctr Hlth Serv Res, Singapore, Singapore
[3] SingHealth, Singapore, Singapore
[4] Duke NUS Med Sch, Duke NUS Acad Med Res Inst, Singapore, Singapore
[5] Univ Sydney, NHMRC Clin Trials Ctr, Sydney, NSW, Australia
关键词
Computed Tomography; head; CT radiation dosage; iterative reconstruction; quality improvement;
D O I
10.1177/2010105816651655
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The use of computed tomography (CT) imaging as a diagnostic modality is increasing rapidly and CT is the dominant contributor to diagnostic medical radiation exposure. The aim of this project was to reduce the effective radiation dose to patients undergoing cranial CT examination, while maintaining diagnostic image quality. Methods: Data from a total of 1003, 132 and 27 patients were examined for three protocols: CT head, CT angiography (CTA), and CT perfusion (CTP), respectively. Following installation of adaptive iterative dose reduction (AIDR) 3D software, tube current was lowered in consecutive cycles, in a stepwise manner and effective radiation doses measured at each step. Results: Baseline effective radiation doses for CT head, CTA and CTP were 1.80, 3.60 and 3.96 mSv, at currents of 300, 280 and 130-150 mA, respectively. Using AIDR 3D and final reduced currents of 160, 190 and 70-100 mA for CT head, CTA and CTP gave effective doses of 1.29, 3.18 and 2.76 mSv, respectively. Conclusion: We demonstrated that satisfactory reductions in the effective radiation dose for CT head (28.3%), CTA (11.6%) and CTP (30.1%) can be achieved without sacrificing diagnostic image quality. We have also shown that iterative reconstruction techniques such as AIDR 3D can be effectively used to help reduce effective radiation dose. The dose reductions were performed within a short period and can be easily achievable, even in busy departments.
引用
收藏
页码:230 / 234
页数:5
相关论文
共 19 条
[1]  
Baughs JA, 2008, RADIOGRAPHICS, V28, P235
[2]  
Bogdanich W., 2010, NY TIMES, pA1
[3]   Reducing the Radiation Dose for CT Colonography Using Adaptive Statistical Iterative Reconstruction: A Pilot Study [J].
Flicek, Kristina T. ;
Hara, Amy K. ;
Silva, Alvin C. ;
Wu, Qing ;
Peter, Mary B. ;
Johnson, C. Daniel .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (01) :126-131
[4]   Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: Phantom study [J].
Funama, Y ;
Awai, K ;
Nakayama, Y ;
Kakei, K ;
Nagasue, N ;
Shimamura, M ;
Sato, N ;
Sultana, S ;
Morishita, S ;
Yamashita, Y .
RADIOLOGY, 2005, 237 (03) :905-910
[5]   Patient radiation doses from adult and pediatric CT [J].
Huda, Walter ;
Vance, Awais .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (02) :540-546
[6]  
*ICRP, 1977, 26 ICRP
[7]  
Irwan R, 2012, VISIONS, V19, P34
[8]   Lowering the Dose in Head CT Using Adaptive Statistical Iterative Reconstruction [J].
Kilic, K. ;
Erbas, G. ;
Guryildirim, M. ;
Arac, M. ;
Ilgit, E. ;
Coskun, B. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (09) :1578-1582
[9]  
Langley GJ., 2009, IMPROVEMENT GUIDE PR, V2nd, P23
[10]   National Conference on Dose Reduction in CT, with an emphasis on pediatric patients [J].
Linton, OW ;
Mettler, FA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (02) :321-329