摘要
Discontinuous magnetization caused by the Barkhausen effect was investigated by using a sensitive pulsed magnetometer available down to 10(-4) emu. An amorphous ferromagnetic ribbon was cut small (0.3 mg) to limit the total number of the domain wall inside. The energy necessary for domain wall motion was estimated at 0.3 J/g for the most probable occurrence at RT. The fractal dimension of the emf waveform caused by the Barkhausen effect with respect to magnetic field was found to be approximately 1.6.
引用
收藏
页码:341 / 342
页数:2