PRESSURIZED AEROSOL VERSUS JET AEROSOL DELIVERY TO MECHANICALLY VENTILATED PATIENTS - COMPARISON OF DOSE TO THE LUNGS

被引:152
作者
FULLER, HD [1 ]
DOLOVICH, MB [1 ]
POSMITUCK, G [1 ]
PACK, WW [1 ]
NEWHOUSE, MT [1 ]
机构
[1] MCMASTER UNIV,ST JOSEPHS HOSP,DEPT NUCL MED,HAMILTON,ONTARIO,CANADA
来源
AMERICAN REVIEW OF RESPIRATORY DISEASE | 1990年 / 141卷 / 02期
关键词
D O I
10.1164/ajrccm/141.2.440
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The purpose of this study was to compare deposition of aerosol to the lung from a metered-dose inhaler (MDI) and aerosol holding chamber and from a jet nebulizer in ventilator-dependent patients. Twenty-one patients were entered into the study, all receiving assisted ventilation and inhaled bronchodilators because of airflow limitation. The average age was 68 yr; there were 10 men and 11 women. The patients were randomized to receive either 4 puffs (800 μg) of radiolabeled fenoterol by MDI of 1.75 ml (1,750 μg) of radiolabeled fenoterol solution by nebulizer. Imaging of lung fields was made by a portable scintillation camera at 5-min intervals during the study. Results showed that 20 patients completed the study, 9 receiving fenoterol by MDI, and 11 by jet nebulizer. Four were exluded from analysis because of previous pneumonectomy, two from each group. Lung deposition measured as a percent of given dose from either system was 5.65 ± 1.09 (mean ± SEM) for MDI plus extension chamber and 1.22 ± 0.35 for jet nebulizer (p < 0.001). Therefore, this trial shows significantly greater efficiency of aerosol deposition to the lung in ventilator-dependent patients when using an MDI plus aerosol holding chamber than when using a jet nebulizer.
引用
收藏
页码:440 / 444
页数:5
相关论文
共 14 条
  • [1] DESIGN AND CHARACTERISTICS OF A PORTABLE BREATH ACTUATED, PARTICLE-SIZE SELECTIVE MEDICAL AEROSOL INHALER
    CORR, D
    DOLOVICH, M
    MCCORMACK, D
    RUFFIN, R
    OBMINSKI, G
    NEWHOUSE, M
    [J]. JOURNAL OF AEROSOL SCIENCE, 1982, 13 (01) : 1 - 7
  • [2] CLINICAL-EVALUATION OF A SIMPLE DEMAND INHALATION MDI AEROSOL DELIVERY DEVICE
    DOLOVICH, M
    RUFFIN, R
    CORR, D
    NEWHOUSE, MT
    [J]. CHEST, 1983, 84 (01) : 36 - 41
  • [3] FLAVIN M, 1986, PEDIATR PULM, V2, P36
  • [4] FRASER I, 1981, AM REV RESPIR DIS, V123, P107
  • [5] HUGHES J M, 1987, Respiratory Care, V32, P1131
  • [6] COMPARISON OF DOMICILIARY NEBULIZED SALBUTAMOL AND SALBUTAMOL FROM A METERED-DOSE INHALER IN STABLE CHRONIC AIR-FLOW LIMITATION
    JENKINS, SC
    HEATON, RW
    FULTON, TJ
    MOXHAM, J
    [J]. CHEST, 1987, 91 (06) : 804 - 807
  • [7] KOHLER D, 1984, RESPIRATION S1, V46, P99
  • [8] LEGARE M, 1988, American Review of Respiratory Disease, V137, P60
  • [9] AEROSOL DELIVERY IN INTUBATED, MECHANICALLY VENTILATED PATIENTS
    MACINTYRE, NR
    SILVER, RM
    MILLER, CW
    SCHULER, F
    COLEMAN, RE
    [J]. CRITICAL CARE MEDICINE, 1985, 13 (02) : 81 - 84
  • [10] MADSEN EB, 1982, EUR J CLIN PHARMACOL, V23, P27