MYOCARDIAL CONTRAST ECHO EFFECT - THE DILEMMA OF CORONARY BLOOD-FLOW AND VOLUME

被引:20
作者
ROVAI, D [1 ]
DEMARIA, AN [1 ]
LABBATE, A [1 ]
机构
[1] UNIV CALIF SAN DIEGO,SAN DIEGO,CA
关键词
D O I
10.1016/0735-1097(95)00119-K
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Despite the useful information provided by myocardial contrast echocardiography, the meaning of myocardial contrast intensity remains elusive. This review is meant to define the contribution of physical and biologic factors in producing myocardial contrast and to elucidate the relative roles of coronary blood how and intramyocardial blood volume in determining contrast effect. The main physical factors influencing the contrast echo effect include the properties of microbubbles as scattering elements (mainly their radius, compressibility, stability and concentration), electronic signal processing, instrument setting and contrast-induced signal attenuation. The effect of these factors can be limited by an appropriate experimental or clinical setup. Biologic factors are less easily controllable, and changes in coronary blood how and alterations in myocardial blood volume appear to be the main determinants of myocardial contrast intensity. Moreover, these factors influence contrast intensity in opposite directions. Both the area under the time intensity curve and the mean transit time of myocardial contrast are inversely related to coronary blood flow but directly related to myocardial vascularity and blood volume. Therefore, an increase in coronary flow not accompanied by an increase in myocardial vascularity and volume is accompanied by a decrease in the area under the curve and mean transit time of contrast. Conversely, an increase in coronary how mediated by augmented myocardial vascularity and volume will produce an increase in the area under the curve and mean transit time. A better understanding of the physical and biologic determinants of contrast echo intensity will be fundamental in the clinical application of new agents and technologies.
引用
收藏
页码:12 / 17
页数:6
相关论文
共 45 条
  • [11] Reisner, Ong, Lichtenberg, Et al., Quantitative assessment of the immediate results of coronary angioplasty by myocardial contrast echocardiography, J Am Coll Cardiol, 13, pp. 852-856, (1989)
  • [12] Goldman, Mindich, Intraoperative cardioplegic contrast echocardiography for assessing myocardial perfusion during open heart surgery, J Am Coll Cardiol, 4, pp. 1029-1034, (1984)
  • [13] Smith, Stanley, Intraoperative contrast echocardiography: a direct approach to measure regional myocardial perfusion, Anesthesiology, 72, pp. 219-221, (1990)
  • [14] Villanueva, Spotnitz, Jayaweera, Dent, Gimple, Kaul, On-line intraoperative quantitation of regional myocardial perfusion during coronary bypass graft operations with myocardial contrast two-dimensional echocardiography, J Thorac Cardiovasc Surg, 104, pp. 1524-1531, (1992)
  • [15] Reisner, Shapiro, Amico, Meltzer, Contrast agents for myocardial perfusion studies, Mechanisms, state of the art, and future prospects, pp. 45-59, (1989)
  • [16] De Jong, Basic principles of ultrasound contrast agents, Acoustic Properties of Ultrasound Contrast Agents, pp. 17-36, (1993)
  • [17] Fritzsch, Hilmann, Kampfe, Muller, Schobel, Siegert, SHU 508 a transpulmonary echo contrast agent, Investigative Radiology, 25, pp. 5160-5161, (1990)
  • [18] Keller, Glasheen, Kaul, Albunex: a safe and effective commercially produced agent for myocardial contrast echocardiography, J Am Soc Echocardiogr, 2, pp. 48-52, (1989)
  • [19] DeMaria, Dittrich, Kwan, Kimura, Myocardial opacification produced by peripheral venous injection of a new ultrasonic contrast agent, Circulation, 88, pp. I-401, (1993)
  • [20] Zwehl, Areeda, Schwartz, Feinstein, Ong, Meerbaum, Physical factors influencing quantitation of two-dimensional contrast-echo amplitudes, J Am Coll Cardiol, 4, pp. 157-164, (1984)