NONINVASIVE ESTIMATION OF CORONARY FLOW RESERVE BY TRANSESOPHAGEAL DOPPLER MEASUREMENT OF CORONARY SINUS FLOW

被引:28
作者
SIOSTROZONEK, P
KRANZ, A
HEINZ, G
RODLER, S
GOSSINGER, H
KREINER, G
STUMPFLEN, A
ZEHETGRUBER, M
SCHWARZ, M
WEBER, H
机构
[1] 2nd Department of Medicine, Division of Cardiology, University of Vienna, A-1090 Vienna
关键词
D O I
10.1016/0002-9149(93)90314-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Currently available methods for the measurement of coronary flow reserve (CFR) are invasive and time-consuming, and need adequate laboratory equipment and staff.1-4 Furthermore, most of these methods are limited by various methodologic problems.5,6 Transesophageal echocardiography enables visualization of the distal coronary sinus in most patients. Accordingly, we investigated the ability of transesophageal echocardiography to calculate CFR by Doppler measurement of coronary sinus flow (CSF) at rest and after dipyridamole administration. © 1993.
引用
收藏
页码:1334 / 1337
页数:4
相关论文
共 12 条
[1]   COMPARISON OF MAXIMAL MYOCARDIAL BLOOD-FLOW DURING ADENOSINE INFUSION WITH THAT OF INTRAVENOUS DIPYRIDAMOLE IN NORMAL MEN [J].
CHAN, SY ;
BRUNKEN, RC ;
CZERNIN, J ;
PORENTA, G ;
KUHLE, W ;
KRIVOKAPICH, J ;
PHELPS, ME ;
SCHELBERT, HR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (04) :979-985
[2]   MEASUREMENT OF CORONARY AND PERIPHERAL ARTERY FLOW BY INTRAVASCULAR ULTRASOUND AND PULSED DOPPLER VELOCIMETRY [J].
EICHHORN, EJ ;
ALVAREZ, LG ;
JESSEN, ME ;
FASS, SM ;
CHAO, RY ;
HAAGEN, D ;
GRAYBURN, PA .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (04) :542-545
[3]   MEASUREMENT OF CORONARY SINUS BLOOD FLOW BY CONTINUOUS THERMODILUTION IN MAN [J].
GANZ, W ;
TAMURA, K ;
MARCUS, HS ;
DONOSO, R ;
YOSHIDA, S ;
SWAN, HJC .
CIRCULATION, 1971, 44 (02) :181-&
[4]   TRANSESOPHAGEAL DOPPLER ECHOCARDIOGRAPHY EVALUATION OF CORONARY BLOOD-FLOW VELOCITY IN BASE-LINE CONDITIONS AND DURING DIPYRIDAMOLE-INDUCED CORONARY VASODILATION [J].
ILICETO, S ;
MARANGELLI, V ;
MEMMOLA, C ;
RIZZON, P .
CIRCULATION, 1991, 83 (01) :61-69
[5]   ASSESSMENT OF CORONARY STENOSES BY MYOCARDIAL PERFUSION IMAGING DURING PHARMACOLOGICAL CORONARY VASODILATION .7. VALIDATION OF CORONARY FLOW RESERVE AS A SINGLE INTEGRATED FUNCTIONAL MEASURE OF STENOSIS SEVERITY REFLECTING ALL ITS GEOMETRIC DIMENSIONS [J].
KIRKEEIDE, RL ;
GOULD, KL ;
PARSEL, L .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (01) :103-113
[6]  
KOCHSIEK K, 1970, CORONARY HEART DISEA, P137
[7]   CORONARY SINUS REFLUX - SOURCE OF ERROR IN MEASUREMENT OF THERMODILUTION CORONARY SINUS FLOW [J].
MATHEY, DG ;
CHATTERJEE, K ;
TYBERG, JV ;
LEKVEN, J ;
BRUNDAGE, B ;
PARMLEY, WW .
CIRCULATION, 1978, 57 (04) :778-786
[8]   CORONARY DILATORY CAPACITY IN IDIOPATHIC DILATED CARDIOMYOPATHY - ANALYSIS OF 16 PATIENTS [J].
OPHERK, D ;
SCHWARZ, F ;
MALL, G ;
MANTHEY, J ;
BALLER, D ;
KUBLER, W .
AMERICAN JOURNAL OF CARDIOLOGY, 1983, 51 (10) :1657-1662
[9]   INVIVO VALIDATION OF A THERMODILUTION METHOD TO DETERMINE REGIONAL LEFT-VENTRICULAR BLOOD-FLOW IN PATIENTS WITH CORONARY-DISEASE [J].
PEPINE, CJ ;
MEHTA, J ;
WEBSTER, WW ;
NICHOLS, WW .
CIRCULATION, 1978, 58 (05) :795-802
[10]   DIPYRIDAMOLE VASODILATOR RESPONSE AFTER HUMAN ORTHOTOPIC HEART-TRANSPLANTATION - QUANTIFICATION BY OXYGEN-15-LABELED WATER AND POSITRON EMISSION TOMOGRAPHY [J].
RECHAVIA, E ;
ARAUJO, LI ;
DESILVA, R ;
KUSHWAHA, SS ;
LAMMERTSMA, AA ;
JONES, T ;
MITCHELL, A ;
MASERI, A ;
YACOUB, MH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (01) :100-106