THE EFFECT OF ANGLE AND FLOW-RATE UPON HEMODYNAMICS IN DISTAL VASCULAR GRAFT ANASTOMOSES - A NUMERICAL-MODEL STUDY

被引:88
作者
FEI, DY
THOMAS, JD
RITTGERS, SE
机构
[1] VIRGINIA COMMONWEALTH UNIV, BIOMED ENGN PROGRAM, RICHMOND, VA 23298 USA
[2] UNIV AKRON, DEPT BIOMED ENGN, AKRON, OH 44325 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 1994年 / 116卷 / 03期
关键词
D O I
10.1115/1.2895739
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Flow in distal end-to-side anastomoses of iliofemoral artery bypass grafts was simulated using a steady flow, three-dimensional numerical model. With the proximal artery occluded, anastomotic angles were varied over 20, 30, 40, 45, 50, 60 and 70 deg while the inlet Reynolds numbers were 100 and 205. Fully developed flow in the graft became somewhat skewed to ward the inner wall with increasing angle for both Reynolds numbers. Separated flow regions were seen along the inner arterial wall (toe region) for angles greater than or equal to 60 deg at Re = 100 and for angles greater than or equal to 45 deg at Re = 205 while a stagnation point existed along the outer arterial wall (floor region)for all cases which moved downstream relative to the toe of the anastomosis with decreasing angles. Normalized shear rates (NSR) along the arterial wall varied widely throughout the anastomotic region with negative values seen in the separation zones and upstream of the stagnation points which increased in magnitude with angle. The NSR increased with distance downstream of the stagnation point and with magnitudes which increased with the angle. Compared with observations from chronic in vivo studies, these results appear to support the hypothesis of greater intimal hyperplasia occurring in regions of low fluid shear.
引用
收藏
页码:331 / 336
页数:6
相关论文
共 35 条
  • [1] HEMODYNAMICS OF VEIN GRAFT STENOSIS
    BANDYK, DF
    SEABROOK, GR
    MOLDENHAUER, P
    LAVIN, J
    EDWARDS, J
    CATO, R
    TOWNE, JB
    [J]. JOURNAL OF VASCULAR SURGERY, 1988, 8 (06) : 688 - 695
  • [2] PULSED DOPPLER VELOCITY PATTERNS PRODUCED BY ARTERIAL ANASTOMOSES
    BANDYK, DF
    ZIERLER, RE
    BERNI, GA
    THIELE, BL
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1983, 9 (01) : 79 - 87
  • [3] BASSIOUNY H S, 1988, Surgical Forum (Chicago), V39, P328
  • [4] ANASTOMOTIC INTIMAL HYPERPLASIA - MECHANICAL INJURY OR FLOW INDUCED
    BASSIOUNY, HS
    WHITE, S
    GLAGOV, S
    CHOI, E
    GIDDENS, DP
    ZARINS, CK
    [J]. JOURNAL OF VASCULAR SURGERY, 1992, 15 (04) : 708 - 717
  • [5] BERGUER R, 1980, ARCH SURG-CHICAGO, V115, P332
  • [6] CHERVU A, 1990, SURG GYNECOL OBSTET, V171, P433
  • [7] CLOWES AW, 1985, AM J PATHOL, V118, P43
  • [8] CRAWSHAW HM, 1980, ARCH SURG-CHICAGO, V115, P1280
  • [9] DeWeese J. A., 1978, VASCULAR GRAFTS, P291
  • [10] DILLEY RJ, 1988, ARCH SURG-CHICAGO, V123, P691