Comparison of Saline Infusion Sonohysterography and Hysteroscopy Findings in Patients With Abnormal Uterine Bleeding

被引:0
|
作者
Alhan, Ali [1 ]
Ozdemipr, Ismail [1 ]
Somunkiran, Asli [1 ]
Demirci, Fuat [1 ]
Yucel, Oguz [1 ]
Bahcebasi, Talat [2 ]
机构
[1] Abant Izzet Baysal Univ, Duzce Fac Med, Dept Obstet & Gynecol, Duzce, Turkey
[2] Abant Izzet Baysal Univ, Duzce Fac Med, Dept Publ Hlth, Duzce, Turkey
关键词
abnormal; uterine bleeding; hysteroscopy; sonohysterography; histopathology;
D O I
暂无
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To establish the accuracy of saline infusion sonohysterography and hysteroscopy in diagnosing uterine pathology in women with abnormal uterine bleeding. Materials and Methods: A total of 39 women with abnormal uterine bleeding were recruited for the study and underwent transvaginal ultrasonography followed by saline infusion sonohysterography. During hysteroscopy, resection of the focal intracavitary lesion was performed. Endometrial sampling was obtained from all patients. Results: Sonohysterographic and hysteroscopic evaluation revealed 25 and 24 endometrial polyps, 7 each submucous myomas, 3 and 1 endometrial hyperplasia, 1 each synechia, and 3 and 6 normal findings, respectively. Comparison of histopathologic findings with other diagnostic tests revealed that hysteroscopy demonstrated a sensitivity of 97%, specificity of 72%, positive predictive value of 94%, negative predictive value of 83% and total sensitivity of 92%. Sonohysterography showed sensitivity of 97%, specificity of 29%, positive predictive value of 86%, negative predictive value of 85% and total sensitivity of 85%. Conclusion: In comparison with hysteroscopy, sonohysterography is a cheaper and easier procedure for detecting endometrial pathologies such as endometrial polyps and submucous myomas with its highly diagnostic value.
引用
收藏
页码:30 / 34
页数:5
相关论文
共 50 条
  • [1] Comparison of saline infusion sonohysterography and hysteroscopy in diagnosis of premenopausal women with abnormal uterine bleeding
    Soguktas, Suna
    Cogendez, Ebru
    Kayatas, Semra Eser
    Asoglu, Mehmet Resit
    Selcuk, Selcuk
    Ertekin, Aktug
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2012, 161 (01) : 66 - 70
  • [2] Comparison of Transvaginal Sonography and Saline Contrast Sonohysterography in Women with Abnormal Uterine Bleeding: Correlation with Hysteroscopy and Histopathology
    Aslam, Muhammad
    Ijaz, Lubna
    Tariq, Shamsa
    Shafqat, Kausar
    Meher-un-Nisa
    Ashraf, Rubina
    Kazmi, Tahira
    INTERNATIONAL JOURNAL OF HEALTH SCIENCES-IJHS, 2007, 1 (01): : 17 - 24
  • [3] Comparison of sonography, sonohysterography, and hysteroscopy for evaluation of abnormal uterine bleeding
    Saidi, MH
    Sadler, RK
    Theis, VD
    Akright, BD
    Farhart, SA
    Villanueva, GR
    JOURNAL OF ULTRASOUND IN MEDICINE, 1997, 16 (09) : 587 - 591
  • [4] Does the addition of saline infusion sonohysterography to transvaginal ultrasonography prevent unnecessary hysteroscopy in premenopausal women with abnormal uterine bleeding?
    Short, John
    Sharp, Benjamin
    Elliot, Nikki
    McEwing, Rachael
    McGeoch, Graham
    Shand, Brett
    Holland, Kieran
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2016, 56 (04): : 432 - 435
  • [5] The evaluation of uterine cavity with saline infusion sonohysterography and hysteroscopy in infertile patients
    Bartkowiak, Robert
    Kaminski, Pawel
    Wielgos, Miroslaw
    Bobrowska, Katarzyna
    NEUROENDOCRINOLOGY LETTERS, 2006, 27 (04) : 523 - 528
  • [6] Abnormal uterine bleeding refractory to medical therapy assessed by saline infusion sonohysterography
    Hauge, Kim
    Ekerhovd, Erling
    Granberg, Seth
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2010, 89 (03) : 367 - 372
  • [7] Transvaginal ultrasonography sonohysterography and operative hysteroscopy for the evaluation of abnormal uterine bleeding
    Krampl, E
    Bourne, T
    Hurlen-Solbakken, H
    Istre, O
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2001, 80 (07) : 616 - 622
  • [8] Comparison of transvaginal sonography, saline infusion sonography, and hysteroscopy in premenopausal women with abnormal uterine bleeding
    de Vries, LD
    Dijkhuizen, FPHLJ
    Mol, BWJ
    Brölmann, HAM
    Moret, E
    Heintz, APM
    JOURNAL OF CLINICAL ULTRASOUND, 2000, 28 (05) : 217 - 223
  • [9] To evaluate the accuracy of saline infusion sonohysterography (SIS) for evaluation of uterine cavity abnormalities in patients with abnormal uterine bleeding
    Chawla I.
    Tripathi S.
    Vohra P.
    Singh P.
    The Journal of Obstetrics and Gynecology of India, 2014, 64 (3) : 197 - 201
  • [10] Comparison of transvaginal 3D sonohysterography with outpatient hysteroscopy in the evaluation of abnormal uterine bleeding
    Katsetos, C.
    Radhakrishnan, S.
    Koumousidis, A.
    Kontoyannis, M.
    Sanoulis, V.
    Spaliaras, D.
    Kouvelas, S.
    CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 2013, 40 (01): : 74 - 77