ULTRASONOGRAPHIC, 3-DIMENSIONAL SCANNING FOR DETERMINATION OF INTRAOCULAR TUMOR VOLUME

被引:0
作者
JENSEN, PK
HANSEN, MK
机构
来源
ACTA OPHTHALMOLOGICA | 1991年 / 69卷 / 02期
关键词
INTRAOCULAR TUMOR; ULTRASOUND; 3-D SCANNING; VOLUME; IMAGE ANALYSIS;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Important prognostic information may be gained from knowing the volume of intraocular tumors, such as choroidal melanomas. To measure such volume, we developed an ultrasonographic 3-D scanning system, which operates by an axial, back and forth, half-turn rotation of a commercial sector scanning transducer, applied directly onto a closed eyelid. Control of movement, data acquisition, and image analysis are accomplished by means of a microcomputer and application-specific software. The elapsed time for scanning and digitizing 11 cross-sectional images across a human eyeball, is 4 sec. Outlines of specific structures are traced manually. The system was tested through repeated, in vitro measurements of known volumes of meat; the mean variation coefficient of these measurements was 2.8%. While accurate estimates were obtained on volumes between 0.01-0.25 ml, these are linearly dependent on gain setting. A patient with a choroidal melanoma was scanned repetitively. The procedures of scanning and tracing contributed about equally to the total variance. This method of scanning allows repeatable, reliable, and easily generated measurements of a tumor's volume and, thus, has great potential for use in the diagnosis and treatment of malignant, intraocular tumors.
引用
收藏
页码:178 / 186
页数:9
相关论文
共 14 条
[1]  
GAMEL JW, 1988, CANCER, V61, P574, DOI 10.1002/1097-0142(19880201)61:3<574::AID-CNCR2820610325>3.0.CO
[2]  
2-9
[3]   PROGNOSTIC-SIGNIFICANCE OF HISTOPATHOLOGICAL PARAMETERS IN MALIGNANT-MELANOMA OF THE CHOROID AS DETERMINED BY PTNM CLASSIFICATION [J].
GOLLNITZ, R ;
LOMMATZSCH, PK .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1988, 192 (04) :296-301
[4]   COMPUTER-AIDED VOLUME MEASUREMENT OF CHOROIDAL MELANOMAS [J].
GOSBELL, AD ;
BARRY, WR ;
FAVILLA, I .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1987, 15 (04) :349-357
[5]  
GUTHOFF R, 1980, GRAEFES ARCH KLIN EX, V214, P139
[6]  
HAIGIS W, 1989, OPHTHALMOLOGISHE ULT, P424
[7]   A SONOGRAPHIC TECHNIQUE TO REDUCE BEAM DISTORTION BY CURVED INTERFACES [J].
KOSSOFF, G ;
CARPENTER, DA ;
ROBINSON, DE ;
OSTRY, D ;
HO, PL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (04) :375-382
[8]  
Kremkau F, 1989, DIAGNOSTIC ULTRASOUN
[9]   RELATIONSHIP OF ULTRASONIC SPECTRAL PARAMETERS TO FEATURES OF TISSUE MICROSTRUCTURE [J].
LIZZI, FL ;
OSTROMOGILSKY, M ;
FELEPPA, EJ ;
RORKE, MC ;
YAREMKO, MM .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1987, 34 (03) :319-329
[10]   THEORY OF FOCUSING RADIATORS [J].
ONEIL, HT .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1949, 21 (05) :516-526