Surface Temperature Measurement in Microscale with Temperature Sensitive Fluorescence

被引:2
作者
Jung, Woonseop
Kim, Sungwook
Kim, Ho-Young
Yoo, Jung Yul
机构
关键词
Temperature Sensitive Fluorescence; Micro Heater; Local Heating; Temperature Field;
D O I
10.3795/KSME-B.2006.30.2.153
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A technique for measuring surface temperature field in microscale is newly proposed, which uses temperature-sensitive fluorescent (TSF) dye coated on the surface and is easily implemented with a fluorescence microscope and a CCD camera. The TSF dye is chosen among mixtures of various chemical compositions including rhodamine B as the fluorescent dye to be most sensitive to temperature change. In order to examine the effectiveness of this temperature measurement technique, numerical analysis and experiment on transient conduction heat transfer for two different substrate materials, i. e., silicon and glass, are performed. In the experiment, to accurately measure the temperature with high resolution temperature calibration curves were obtained with very fine spatial units. The experimental results agree qualitatively well with the numerical data in the silicon and glass substrate cases so that the present temperature measurement method proves to be quite reliable. In addition, it is noteworthy that the glass substrate is more appropriate to be used as thermally-insulating locally-heating heater in micro thermal devices. This fact is identified in the temperature measuring experiment on the locally-heating heaters made on the wafer of silicon and glass substrates. Accordingly, this technique is capable of accurate and non-intrusive high-resolution measurement of temperature field in microscale.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 17 条
[1]  
Azar K., 1991, 1991 Proceedings, Seventh Annual IEEE Semiconductor Thermal Measurement and Management Symposium (Cat. No.91CH2972-8), P23, DOI 10.1109/STHERM.1991.152907
[2]   Transient liquid crystal thermometry of microfabricated PCR vessel arrays [J].
Chaudhari, AM ;
Woudenberg, TM ;
Albin, M ;
Goodson, KE .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 1998, 7 (04) :345-355
[3]   Application of 2-D LIF temperature measurements in water using a Nd:YAG laser [J].
Coolen, MCJ ;
Kieft, RN ;
Rindt, CCM ;
van Steenhoven, AA .
EXPERIMENTS IN FLUIDS, 1999, 27 (05) :420-426
[4]   Dual emission laser induced fluorescence for direct planar scalar behavior measurements [J].
Coppeta, J ;
Rogers, C .
EXPERIMENTS IN FLUIDS, 1998, 25 (01) :1-15
[5]   The effect of photobleaching and velocity fluctuations on single-point LIF measurements [J].
Crimaldi, JP .
EXPERIMENTS IN FLUIDS, 1997, 23 (04) :325-330
[6]   Simultaneous measurement of temperature and velocity using two-colour LIF combined with PIV with a colour CCD camera and its application to the turbulent buoyant plume [J].
Funatani, S ;
Fujisawa, N ;
Ikeda, H .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (05) :983-990
[7]   Combined planar laser-induced fluorescence-particle image velocimetry technique for velocity and temperature fields [J].
Hishida, K ;
Sakakibara, J .
EXPERIMENTS IN FLUIDS, 2000, 29 (Suppl 1) :S129-S140
[8]  
Hornak J.P., 2002, ENCY IMAGING SCI TEC, P390
[9]  
KIM HJ, 2001, P 2001 ASME INT MECH
[10]  
Liu J, 2002, ELECTROPHORESIS, V23, P1531, DOI 10.1002/1522-2683(200205)23:10<1531::AID-ELPS1531>3.0.CO