ADVERSE REACTIONS TO XENON-ENHANCED CT CEREBRAL BLOOD-FLOW DETERMINATION

被引:78
|
作者
LATCHAW, RE
YONAS, H
PENTHENY, SL
GUR, D
机构
[1] UNIV PITTSBURGH,DEPT RADIOL,PITTSBURGH,PA 15213
[2] UNIV PITTSBURGH,DEPT NEUROL SURG,PITTSBURGH,PA 15213
关键词
D O I
10.1148/radiology.163.1.3823444
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:251 / 254
页数:4
相关论文
共 50 条
  • [1] Adverse reaction to xenon-enhanced CT cerebral blood flow measurement
    Fang, H
    Xu, JX
    Zhang, ZM
    ACTA NEUROLOGICA SCANDINAVICA, 1996, 93 : 50 - 50
  • [2] CEREBRAL BLOOD-FLOW - MEASUREMENT WITH XENON-ENHANCED DYNAMIC HELICAL CT
    NAMBU, K
    SUZUKI, R
    HIRAKAWA, K
    RADIOLOGY, 1995, 195 (01) : 53 - 57
  • [3] COMPARISON OF XENON-ENHANCED CT WITH ULTRAFAST CT FOR MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW
    GOBBEL, GT
    CANN, CE
    FIKE, JR
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1993, 14 (03) : 543 - 550
  • [4] XENON-ENHANCED COMPUTERIZED TOMOGRAPHIC CEREBRAL BLOOD-FLOW MAPPING
    YONAS, H
    GUR, D
    WOLFSON, SK
    GOOD, WF
    GOOD, BC
    LATCHAW, RE
    LANCET, 1984, 1 (8390): : 1357 - 1357
  • [5] XENON-ENHANCED CT OF THE BRAIN - EFFECT OF FLOW ACTIVATION ON DERIVED CEREBRAL BLOOD-FLOW MEASUREMENTS
    GOOD, WF
    GUR, D
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1991, 12 (01) : 83 - 85
  • [6] PHYSIOLOGIC CHANGES IN REGIONAL CEREBRAL BLOOD-FLOW DEFINED BY XENON-ENHANCED CT-SCANNING
    DRAYER, BP
    WOLFSON, SK
    BOEHNKE, M
    DUJOVNY, M
    ROSENBAUM, AE
    COOK, EE
    NEURORADIOLOGY, 1978, 16 : 220 - 223
  • [7] STABLE XENON-ENHANCED CT MEASUREMENT OF CEREBRAL BLOOD-FLOW IN REVERSIBLE FOCAL ISCHEMIA IN BABOONS
    YONAS, H
    GUR, D
    CLAASSEN, D
    WOLFSON, SK
    MOOSSY, J
    JOURNAL OF NEUROSURGERY, 1990, 73 (02) : 266 - 273
  • [8] IMAGING CEREBRAL-ISCHEMIA - STABLE XENON-ENHANCED CT CEREBRAL BLOOD-FLOW MAPPING IN THE ACUTE PERIOD
    HECHT, ST
    YONAS, H
    JOHNSON, DW
    LATCHAW, RE
    GUR, D
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1988, 9 (05) : 1038 - 1038
  • [9] MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW (RCBF) BY XENON-ENHANCED CT (XE-CT) - INTRODUCING A SIMPLIFIED METHOD
    SUZUKI, R
    HIRATSUKA, H
    TSURUOKA, S
    INABA, Y
    OHNO, K
    NEURORADIOLOGY, 1985, 27 (01) : 89 - 89
  • [10] MAPPING OF LOCAL CEREBRAL BLOOD-FLOW WITH STABLE XENON-ENHANCED CT AND THE CURVE-FITTING METHOD OF ANALYSIS
    TOUHO, H
    KARASAWA, J
    NAKAGAWARA, J
    TAZAWA, T
    YAMADA, K
    KURIYAMA, Y
    ASAI, M
    KAGAWA, M
    KOBAYASHI, K
    YASUE, H
    RADIOLOGY, 1988, 168 (01) : 207 - 212