The clinical effectiveness of the streamlined liner of pharyngeal airway (SLIPA (TM)) compared with the laryngeal mask airway ProSeal (TM) during general anesthesia

被引:26
作者
Choi, Yun Mi [1 ]
Cha, Su Man [1 ]
Kang, Hyun [1 ]
Baek, Chong Wha [1 ]
Jung, Yong Hun [1 ]
Woo, Young Cheol [1 ]
Kim, Jin Yun [1 ]
Koo, Gill Hoi [1 ]
Park, Sun Gyoo [1 ]
机构
[1] Chung Ang Univ, Coll Med, Dept Anesthesiol & Pain Med, 224-1 Heukseok-1 Dong, Seoul 156756, South Korea
关键词
Airway; Anesthesia; PLMA; SLIPA; Supraglottic airway;
D O I
10.4097/kjae.2010.58.5.450
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: The aim of this study was to compare the streamlined liner of the pharynx airway (SLIPA), a new supraglottic airway device (SGA), with the laryngeal mask airway ProSeal (TM) (PLMA) during general anesthesia. Methods: Sixty patients were randomly allocated to two groups; a PLMA group (n = 30) or a SLIPA group (n = 30). Ease of use, first insertion success rate, hemodynamic responses to insertion, ventilatory efficiency and positioning confirmed by fiberoptic bronchoscopy were assessed. Lung mechanics data were collected with side stream spirometry at 10 minutes after insertion. We also compared the incidence of blood stain, incidence and severity of postoperative sore throat and other complications. Results: First attempt success rates were 93.3% and 73.3%, and mean insertion time was 7.3 sec and 10.5 sec in PLMA and SLIPA. There was a significant rise in all of hemodynamic response from the pre-insertion value at one minute following insertion of SLIPA. But, insertion of PLMA was no significant rise in hemodynamic response. There was no statistically significant difference in the mean maximum sealing pressure, gas leakage, lung mechanics data, gastric distension, postoperative sore throat and other complication between the two groups. Blood stain were noted on the surface of the device in 40% (n = 12) in the SLIPA vs. 6.7% (n = 2) in the PLMA. Conclusions: The SLIPA is a useful alternative to the PLMA and have comparable efficacy and complication rates. If we acquire the skill to use, SLIPA may be considered as primary SGA devices during surgery under general anesthesia.
引用
收藏
页码:450 / 457
页数:8
相关论文
共 28 条
  • [1] THE LARYNGEAL MASK AIRWAY - ITS FEATURES, EFFECTS AND ROLE
    ASAI, T
    MORRIS, S
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1994, 41 (10): : 930 - 960
  • [2] The LMA 'ProSeal' - a laryngeal mask with an oesophageal vent
    Brain, AIJ
    Verghese, C
    Strube, PJ
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2000, 84 (05) : 650 - 654
  • [3] The ProSeal laryngeal mask airway - A randomized, crossover study with the standard laryngeal mask airway in paralyzed, anesthetized patients
    Brimacombe, J
    Keller, C
    [J]. ANESTHESIOLOGY, 2000, 93 (01) : 104 - 109
  • [4] Lingual nerve injury associated with the ProSeal laryngeal mask airway: a case report and review of the literature
    Brimacombe, J
    Clarke, G
    Keller, C
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2005, 95 (03) : 420 - 423
  • [5] A multicenter study comparing the ProSeal™ and Classic™ laryngeal mask airway in anesthetized, nonparalyzed patients
    Brimacombe, J
    Keller, C
    Fullekrug, B
    Agrò, F
    Rosenblatt, W
    Dierdorf, SF
    de Lucas, EG
    Capdevilla, X
    Brimacombe, N
    [J]. ANESTHESIOLOGY, 2002, 96 (02) : 289 - 295
  • [6] THE LARYNGEAL MASK AIRWAY AND POSITIVE-PRESSURE VENTILATION
    DEVITT, JH
    WENSTONE, R
    NOEL, AG
    ODONNELL, MP
    [J]. ANESTHESIOLOGY, 1994, 80 (03) : 550 - 555
  • [7] RETRACTED: CIRCULATORY RESPONSES TO LARYNGEAL MASK AIRWAY INSERTION OR TRACHEAL INTUBATION IN NORMOTENSIVE AND HYPERTENSIVE PATIENTS (Retracted article. See vol. 59, pg. 1177, 2012)
    FUJII, Y
    TANAKA, H
    TOYOOKA, H
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1995, 42 (01): : 32 - 36
  • [8] A comparison between the PLA Cobra™ and the laryngeal mask airway Unique™ during spontaneous ventilation:: A randomized prospective study
    Gaitini, L
    Yanovski, B
    Somri, M
    Vaida, S
    Riad, T
    Alfery, D
    [J]. ANESTHESIA AND ANALGESIA, 2006, 102 (02) : 631 - 636
  • [9] Protein contamination of the laryngeal mask airway and its relationship to re-use
    Greenwood, J.
    Green, N.
    Power, G.
    [J]. ANAESTHESIA AND INTENSIVE CARE, 2006, 34 (03) : 343 - 346
  • [10] Hein Cindy, 2006, Emerg Med Australas, V18, P478, DOI 10.1111/j.1742-6723.2006.00894.x