MODEL ANALYSIS OF BIOLOGICAL OXYGEN-TRANSFER ENHANCEMENT IN SURFACE-AERATED BIOREACTORS

被引:19
作者
JU, LK
SUNDARARAJAN, A
机构
[1] Department of Chemical Engineering, The University of Akron, Akron, Ohio
关键词
OXYGEN TRANSFER; SURFACE AERATION; BIOLOGICAL ENHANCEMENT; PHYSICAL BLOCKING; INTERFACIAL SURFACTANT FILM; INTERFACIAL CELL LAYER;
D O I
10.1002/bit.260401108
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A model was developed to evaluate the effects of cells and surfactants on oxygen transfer in surface-aerated bioreactors. The model assumed the presence of serial layers of adsorbed surfactants and microorganisms directly adjacent to the gas-liquid interface due to their surface activities, followed by a stagnant liquid layer to account for the oxygen transfer resistance in the liquid phase. The interfacial surfactant film, although posing as an additional resistance, was found to have negligible effect on the oxygen transfer rate because of its extremely small thickness as compared to the cell monolayer and the stagnant liquid layer. On the other hand, cells affect oxygen transfer by two mechanisms: the biological enhancement due to the respiration of interfacial cells and the physical blocking resulting from the semipermeable nature of cell bodies. Due to the low specific oxygen uptake rates of the sludges, the two mechanisms were found to be of comparable importance in activated-sludge systems; the oxygen transfer enhancement factor, E, varied from about 0.97 to 1.10 depending on the operating conditions. The biological enhancement effect, however, predominated in fermentations of actively growing bacteria. At relatively low agitation speed (e.g., 300 rpm), the value of E could reach about 3 to 5 in fermentations with high cell concentrations. Effects of other operating variables, such as the agitation intensity, the oxygen content in the mixed liquor, and the bulk cell concentration, on biological oxygen transfer enhancement were also studied.
引用
收藏
页码:1343 / 1352
页数:10
相关论文
共 42 条
[1]  
AIBA S, 1963, J FERM TECH, V41, P74
[2]  
ALBERTSON OE, 1975, J WATER POLLUT CON F, V47, P976
[3]   THE EFFECTS OF CELLS ON OXYGEN-TRANSFER COEFFICIENTS .1. CELL ACCUMULATION AROUND BUBBLES [J].
ANDREWS, GF ;
FONTA, JP ;
MARROTTA, E ;
STROEVE, P .
CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1984, 29 (03) :B39-B46
[4]   OXYGEN TRANSFER AND AGITATION IN SUBMERGED FERMENTATIONS - MASS TRANSFER OF OXYGEN IN SUBMERGED FERMENTATION OF STREPTOMYCES-GRISEUS [J].
BARTHOLOMEW, WH ;
KAROW, EO ;
SFAT, MR ;
WILHELM, RH .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1950, 42 (09) :1801-1809
[5]  
Benefield L.D., 1980, BIOL PROCESS DESIGN
[6]   OXYGEN TRANSFER MECHANISMS IN GLUCONIC ACID FERMENTATION BY PSEUDOMONAS OVALIS [J].
BENNETT, GF ;
KEMPE, LL .
BIOTECHNOLOGY AND BIOENGINEERING, 1964, 6 (03) :347-&
[7]  
BENNETT GF, 1965, 20TH P PURD IND WAST, P435
[8]   ESTIMATION OF THICKNESS OF BACTERIAL FILMS AT AN AIR-WATER-INTERFACE [J].
BUNGAY, HR ;
MASAK, RD .
BIOTECHNOLOGY AND BIOENGINEERING, 1981, 23 (05) :1155-1157
[9]  
Clesceri LS., 1989, STANDARD METHODS EXA, V17
[10]   INFLUENCE OF SAMPLING METHOD ON CHEMICAL COMPOSITION OF WATER SURFACE FILM [J].
DAUMAS, RA ;
LABORDE, PL ;
MARTY, JC ;
SALIOT, A .
LIMNOLOGY AND OCEANOGRAPHY, 1976, 21 (02) :319-326