THE RISK OF SMALL ST-JUDE AORTIC-VALVE PROSTHESES

被引:72
|
作者
KRATZ, JM
SADE, RM
CRAWFORD, FA
CRUMBLEY, AJ
STROUD, MR
机构
[1] Division of Cardiothoracic Surgery, Medical University of South Carolina, Charleston, SC
关键词
D O I
10.1016/0003-4975(94)91339-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We reviewed our 12-year experience with 254 adult patients who had St. Jude valves in the aortic position and used multivariate analysis to examine risk factors possibly affecting long-term morbidity and mortality. Nineteen-millimeter or 21-mm valves were implanted in 115 patients. Poor preoperative congestive heart failure status was associated with persistent congestive heart failure on late follow-up. Preoperative congestive heart failure and coronary artery disease were the only predictors of overall late death. Late deaths associated with heart failure and late sudden deaths were examined separately. Preoperative degree of heart failure was the only predictor of late death with associated heart failure. The implantation of a 19- or 21-mm valve in patients with a body surface area greater than 1.9 m(2) somewhat increased the risk of late sudden death. In patients with a body surface area greater than 1.9 m(2) and with a 19-mm or 21-mm annulus, consideration should be given to using a high-performance St. Jude valve or performing an annulus-enlarging procedure if this can be done with negligible morbidity.
引用
收藏
页码:1114 / 1119
页数:6
相关论文
共 50 条
  • [1] CLINICAL COMPARISON OF ST JUDE AND PORCINE AORTIC-VALVE PROSTHESES
    DOUGLAS, PS
    HIRSHFELD, JW
    EDIE, RN
    HARKEN, AH
    STEPHENSON, LW
    EDMUNDS, LH
    CIRCULATION, 1985, 72 (03) : 135 - 139
  • [2] THROMBOSIS OF AORTIC ST-JUDE VALVE
    PRABHU, S
    FRIDAY, KJ
    REYNOLDS, D
    ELKINS, R
    LAZZARA, R
    ANNALS OF THORACIC SURGERY, 1986, 41 (03) : 332 - 333
  • [3] EARLY CLINICAL-EVALUATION AFTER AORTIC-VALVE REPLACEMENT WITH THE ST-JUDE MEDICAL VALVE IN PATIENTS WITH A SMALL AORTIC ROOT
    GILL, CC
    KING, HC
    LYTLE, BW
    COSGROVE, DM
    GOLDING, LAR
    LOOP, FD
    CIRCULATION, 1982, 66 (02) : 147 - 149
  • [4] A PRECAUTION WHEN USING THE ST-JUDE MEDICAL PROSTHESIS IN THE AORTIC-VALVE POSITION
    ROSS, EM
    ROBERTS, WC
    AMERICAN JOURNAL OF CARDIOLOGY, 1984, 54 (01) : 231 - 233
  • [5] ENTRAPMENT OF BOTH LEAFLETS OF ST-JUDE MEDICAL AORTIC-VALVE PROSTHESIS IN A CHILD
    SHARMA, A
    JOHNSON, DC
    CARTMILL, TB
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1983, 86 (03) : 453 - 455
  • [6] APPLICATION OF THE CONTINUITY EQUATION TO THE EVALUATION OF ST-JUDE PROSTHETIC AORTIC-VALVE DYSFUNCTION
    SAAD, RM
    OLMOS, L
    RUBIO, N
    ZOGHBI, WA
    CIRCULATION, 1994, 90 (04) : 115 - 115
  • [7] TRANSESOPHAGEAL COLOR FLOW DOPPLER AND ECHOCARDIOGRAPHIC FEATURES OF NORMAL AND REGURGITANT ST-JUDE MEDICAL PROSTHESES IN THE AORTIC-VALVE POSITION
    ALAM, M
    SERWIN, JB
    ROSMAN, HS
    SHETH, M
    SUN, I
    SILVERMAN, NA
    GOLDSTEIN, S
    AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (10) : 873 - 875
  • [8] DOPPLER ECHOCARDIOGRAPHY IN 180 NORMALLY FUNCTIONING ST-JUDE MEDICAL AORTIC-VALVE PROSTHESES - EARLY AND LATE POSTOPERATIVE ASSESSMENTS
    PERIN, EC
    JIN, BS
    DECASTRO, CM
    FERGUSON, JJ
    HALL, RJ
    CHEST, 1991, 100 (04) : 988 - 990
  • [9] REPOSE AND STRESS HEMODYNAMICS AFTER AORTIC-VALVE REPLACEMENT WITH ST-JUDE MEDICAL PROSTHESIS
    TRIEB, G
    FASSBENDER, HD
    MERTENS, HM
    MANNEBACH, H
    GLEICHMANN, U
    ZEITSCHRIFT FUR KARDIOLOGIE, 1980, 69 (03): : 201 - 201
  • [10] HEMODYNAMIC AND HEMOLYTIC FEATURES OF THE ST-JUDE MEDICAL VALVE PROSTHESES
    SEZAI, Y
    UMEDA, S
    OKAZAKI, T
    OKAMOTO, I
    RIKUKAWA, H
    SHIONO, M
    JOURNAL OF CARDIOVASCULAR SURGERY, 1984, 25 (01) : 16 - 24