DETERMINATION OF CHLORITE AND CHLORATE IN CHLORINATED AND CHLORAMINATED DRINKING-WATER BY FLOW-INJECTION ANALYSIS AND ION CHROMATOGRAPHY

被引:41
|
作者
DIETRICH, AM
LEDDER, TD
GALLAGHER, DL
GRABEEL, MN
HOEHN, RC
机构
[1] Environmental Engineering and Environmental Sciences Division, Department of Civil Engineering, Virginia Tech, Virginia
关键词
D O I
10.1021/ac00029a009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This research investigated the determination of chlorite and chlorate concentrations in drinking water by flow injection analysis (FIA) with iodometric detection and ion chromatography (IC) with conductivity detection. The FIA and IC methods were accurate and effective for reagent water. The IC method was accurate for measurement of chlorite and chlorate concentration in drinking water even in the presence of other oxidants including chloramines. However, FIA was affected by chloramines and other oxidants in drinking water, resulting in inaccurate determinations. While chlorite concentrations were unstable in chlorinated drinking water, addition of sodium oxalate increased the stability to up to 3 days and addition of ethylenediamine increased stability to up to 18 days. Chlorate concentration were stable in drinking water for up to 18 days with or without a preservative.
引用
收藏
页码:496 / 502
页数:7
相关论文
共 50 条
  • [31] SPECTROPHOTOMETRIC APPROACHES TO THE DETERMINATION OF WATER IN ACETONE BY FLOW-INJECTION ANALYSIS
    GUZMAN, M
    PAVON, JLP
    GONZALO, ER
    HATFIELD, C
    RUZICKA, J
    CHRISTIAN, GD
    ANALYST, 1991, 116 (10) : 1043 - 1049
  • [32] DETERMINATION OF WATER BY FLOW-INJECTION ANALYSIS WITH THE KARL FISCHER REAGENT
    KAGEVALL, I
    ASTROM, O
    CEDERGREN, A
    ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) : 199 - 208
  • [33] Determination of total phosphorus in water samples by flow-injection analysis
    Zhang, JF
    Wang, XR
    Shen, H
    Wu, JC
    Xue, YQ
    CHEMIA ANALITYCZNA, 2004, 49 (04): : 527 - 533
  • [34] THE EVALUATION AND COMPARISON OF ION CHROMATOGRAPHY, SEGMENTED FLOW-ANALYSIS AND FLOW-INJECTION ANALYSIS FOR THE DETERMINATION ON NITRATE IN NATURAL SURFACE WATERS
    BURKE, EM
    SUAREZ, FX
    HILLMAN, DC
    HEITHMAR, EM
    WATER RESEARCH, 1989, 23 (04) : 519 - 521
  • [35] QUANTITATIVE-ANALYSIS OF CHLORINE DIOXIDE IN DRINKING-WATER .2. DETERMINATION OF CHLORDIOXIDE, CHLORITE AND CHLORINE
    WEIL, D
    ZEITSCHRIFT FUR WASSER UND ABWASSER FORSCHUNG-JOURNAL FOR WATER AND WASTEWATER RESEARCH, 1980, 13 (05): : 188 - 192
  • [36] Flow-injection analysis determination of thiocyanate in industrial waste water
    Patel, R
    Patel, KS
    CHEMIA ANALITYCZNA, 1999, 44 (05): : 917 - 923
  • [37] DETERMINATION OF CHLORHEXIDINE BY FLOW-INJECTION ANALYSIS
    LAU, KK
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 332 (04): : 370 - 371
  • [38] DETERMINATION OF PHOSPHATE IN SEA-WATER BY FLOW-INJECTION ANALYSIS WITH INJECTION OF REAGENT
    JOHNSON, KS
    PETTY, RL
    ANALYTICAL CHEMISTRY, 1982, 54 (07) : 1185 - 1187
  • [39] Modeling and analysis of chlorine dioxide, chlorite, and chlorate propagation in a drinking water distribution system
    Sorlini, Sabrina
    Biasibetti, Michela
    Gialdini, Francesca
    Muraca, Alessandro
    JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA, 2016, 65 (08): : 597 - 611
  • [40] USING REDUCING AGENTS TO ELIMINATE CHLORINE DIOXIDE AND CHLORITE ION RESIDUALS IN DRINKING-WATER
    GRIESE, MH
    HAUSER, K
    BERKEMEIER, M
    GORDON, G
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1991, 83 (05): : 56 - 61