COMPARISON OF INFRARED AND HELIUM-NEON LASERS IN THE MEASUREMENT OF BLOOD-FLOW IN HUMAN SKIN BY THE LASER-DOPPLER TECHNIQUE

被引:0
|
作者
COULSON, ML [1 ]
HAYES, NA [1 ]
FOREMAN, JC [1 ]
机构
[1] UNIV LONDON UNIV COLL,DEPT PHARMACOL,GOWER ST,LONDON WC1E 6BT,ENGLAND
来源
SKIN PHARMACOLOGY | 1992年 / 5卷 / 02期
关键词
LASER-DOPPLER; BLOOD FLOW; HUMAN SKIN; HISTAMINE;
D O I
暂无
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Histamine-induced changes in blood flow in normal human skin were assessed by laser-Doppler velocimetry using 2 lasers of different wavelengths: 780 nm infrared and 633 nm helium-neon. The visible flare response in skin was also measured by planimetry. Laser-Doppler velocimetry was shown to detect both the magnitude of the change in blood flow caused by histamine and also the extent of the changes in the skin. Both parameters were related to the dose of histamine, which ranged between 25 and 750 pmol/site. There was good correlation between the magnitude of the histamine-induced blood flow change and the extent of the response. The flare induced by histamine and measured by planimetry was similar in extent to the blood flow change, recorded by laser-Doppler velocimetry. No difference in either the magnitude or the extent of blood flow changes in response to histamine, as measured by laser-Doppler velocimetry, were found when lasers of different wavelengths were used.
引用
收藏
页码:81 / 86
页数:6
相关论文
共 22 条
  • [1] FREQUENCY STABILIZATION OF MULTIMODE HELIUM-NEON LASERS IN LASER DOPPLER FLOWMETRY
    DEBLEN, H
    OBERG, PA
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1991, 29 (05) : 470 - 474
  • [2] A LASER DOPPLER SCANNER FOR IMAGING BLOOD-FLOW IN SKIN
    ESSEX, TJH
    BYRNE, PO
    JOURNAL OF BIOMEDICAL ENGINEERING, 1991, 13 (03): : 189 - 194
  • [3] DYNAMICS OF THE SKIN BLOOD-FLOW RESPONSE TO HISTAMINE - COMPARISON OF THE EFFECTS OF CETIRIZINE AND LORATADINE ON THE SKIN-RESPONSE TO A HISTAMINE DRY PRICK TEST MONITORED WITH LASER-DOPPLER FLOWMETRY
    VANNESTE, D
    RIHOUX, JP
    DERMATOLOGY, 1993, 186 (04) : 281 - 283
  • [4] EFFECT OF OXYMETAZOLINE ON NASAL AND SINUS MUCOSAL BLOOD-FLOW IN THE RABBIT AS MEASURED WITH LASER-DOPPLER FLOWMETRY
    AKERLUND, A
    BENDE, M
    ARFORS, KE
    INTAGLIETTA, M
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1993, 102 (02) : 123 - 126
  • [5] APPLICABILITY OF LASER-DOPPLER FLOWMETRY FOR CEREBRAL BLOOD-FLOW MONITORING IN NEUROLOGICAL INTENSIVE-CARE
    HABERL, RL
    VILLRINGER, A
    DIRNAGL, U
    ACTA NEUROCHIRURGICA, 1993, : 64 - 68
  • [6] 2-DIMENSIONAL BLOOD-FLOW DETERMINATIONS IN ALLERGIC REACTIONS USING LASER-DOPPLER SCANNING
    STUCKER, M
    AUER, T
    HOFFMANN, K
    ALTMEYER, P
    CONTACT DERMATITIS, 1995, 33 (05) : 299 - 303
  • [7] Development of a Wireless Sensor for the Measurement of Chicken Blood Flow Using the Laser Doppler Blood Flow Meter Technique
    Nishihara, Kei
    Iwasaki, Wataru
    Nakamura, Masaki
    Higurashi, Eiji
    Soh, Tomoki
    Itoh, Toshihiro
    Okada, Hironao
    Maeda, Ryutaro
    Sawada, Renshi
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (06) : 1645 - 1653
  • [8] PLATELET-ACTIVATING-FACTOR AND HISTAMINE EFFECTS IN SYNOVIAL BLOOD-FLOW EVALUATED BY LASER-DOPPLER FLOWMETRY
    ROCHA, FAC
    JANCAR, S
    FRAGA, CAB
    TIMOIARIA, C
    DEBRUMFERNANDES, AJ
    JOURNAL OF RHEUMATOLOGY, 1993, 20 (08) : 1374 - 1377
  • [9] PHOTOCHEMICALLY INDUCED SPINAL-CORD ISCHEMIA IN RATS - ASSESSMENT OF BLOOD-FLOW BY LASER-DOPPLER FLOWMETRY
    HAO, JX
    HERREGODTS, P
    LIND, G
    MEYERSON, B
    SEIGER, A
    WIESENFELDHALLIN, Z
    ACTA PHYSIOLOGICA SCANDINAVICA, 1994, 151 (02): : 209 - 215
  • [10] LASER-DOPPLER FLOWMETRY COMPARED TO INTRAVITAL MICROSCOPY FOR ASSESSMENT OF BLOOD-FLOW IN THE NASAL-MUCOSA OF THE RABBIT
    AKERLUND, A
    BENDE, M
    INTAGLIETTA, M
    ARFORS, KE
    ACTA OTO-LARYNGOLOGICA, 1992, 112 (04) : 691 - 696