摘要
Two herds of beef cattle were maintained beneath a +/-500 kV direct-current transmission line during a 30-month period, and were compared with two similar herds maintained away from the transmission line. Exposures of animals under the line were five to 30 times greater than those of control animals, depending on the parameter of interest, with average exposure magnitudes of 5.6 kV/m, 4.1 nA/m2, and 13 k ions/cm3, respectively, for electric field, ion current, and density of ions. Productivity and health status of cows and calves were similar between lines and control treatments. Mean body mass of cows increased with maturity, from 438 kg in 1985 to 496 kg in 1987. Calf gain averaged 0.93 kg per head per day. No unusual sources of mortality were observed. Based on this confinement study, beef cattle permitted to graze in the vicinity of a high-voltage, direct-current transmission lines are not expected to experience any decrease in frequency of conception, calving, growth rate, or survival.
引用
收藏
页码:273 / 282
页数:10
相关论文
共 50 条
  • [41] PIPELINE VOLTAGE HAZARDS ON HIGH-VOLTAGE AC TRANSMISSION-LINE RIGHTS-OF-WAY
    CHERNEY, EA
    MATERIALS PERFORMANCE, 1975, 14 (03) : 29 - 33
  • [42] ACCELERATION OF WOUND-HEALING WITH HIGH-VOLTAGE PULSATING DIRECT-CURRENT
    FEEDAR, JA
    KLOTH, LC
    PHYSICAL THERAPY, 1985, 65 (05): : 741 - 741
  • [43] Calculation of the Surface Electric Field Distribution of High-Voltage Direct Current Transmission Line
    Hao J.
    Wang H.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2019, 34 : 14 - 21
  • [44] TURN-OFF OVERVOLTAGES IN HIGH-VOLTAGE DIRECT-CURRENT VALVES
    HARDERS, CF
    POVH, D
    SIEMENS FORSCHUNGS-UND ENTWICKLUNGSBERICHTE-SIEMENS RESEARCH AND DEVELOPMENT REPORTS, 1977, 6 (02): : 69 - 73
  • [45] POSSIBLE UTILIZATION OF HIGH-VOLTAGE DIRECT-CURRENT TRANSMISSION - EXAMPLE OF THE CABORA-BASSA-APOLLO SELSYN
    PESCH, H
    BRENNSTOFF-WARME-KRAFT, 1980, 32 (07): : 277 - 283
  • [46] EFFECT OF HIGH-ALTITUDE ON HIGH-VOLTAGE AC TRANSMISSION-LINE CORONA PHENOMENA
    CHARTIER, VL
    LEE, LY
    DICKSON, LD
    MARTIN, KE
    IEEE TRANSACTIONS ON POWER DELIVERY, 1987, 2 (01) : 225 - 237
  • [47] TECHNICAL AND ECONOMIC DATA FOR HIGH-VOLTAGE ALTERNATING-CURRENT AND DIRECT-CURRENT STATIONS
    不详
    ELEKTROTECHNISCHE ZEITSCHRIFT ETZ-A, 1977, 98 (11): : 721 - 727
  • [48] Dynamic simulation and experimental study of inspection robot for high-voltage transmission-line
    Xiao-hui Xiao
    Gong-ping Wu
    E Du
    Tie-lin Shi
    Journal of Central South University of Technology, 2005, 12 : 726 - 731
  • [49] Dynamic simulation and experimental study of inspection robot for high-voltage transmission-line
    Xiao, XH
    Wu, GP
    Du, E
    Shi, TL
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2005, 12 (06): : 726 - 731
  • [50] Dynamic simulation and experimental study of inspection robot for high-voltage transmission-line
    肖晓晖
    吴功平
    杜娥
    史铁林
    Journal of Central South University of Technology(English Edition), 2005, (06) : 726 - 731