Study to assess the relationship between insertion torque value and implant stability quotient and its influence on timing of functional implant loading

被引:13
|
作者
Sarfaraz, Hasan [1 ]
Johri, Shefali [2 ]
Sucheta, P. [1 ]
Rao, Sripathi [2 ]
机构
[1] Yenepoya Dent Coll, Dept Prosthodont & Crown & Bridge, Univ Rd, Mangalore 575018, Karnataka, India
[2] Yenepoya Dent Coll, Dept Oral & Maxillofacial Surg, Mangalore, Karnataka, India
关键词
Implant stability quotient; insertion torque value; Osstell-implant stability quotient device; primary stability; resonance frequency analysis; secondary stability; time of loading implants;
D O I
10.4103/jips.jips_203_17
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: One of the crucial requirements for the success of implants is to achieve good stability. Two well-accepted quantitative methods to assess implant stability, the insertion torque value (ITV), and resonance frequency analysis (RFA) can be a valuable adjunct to radiological and clinical examination. This study was conducted to assess the relationship between ITVs and implant stability quotient (ISQ) and its influence on timing of functional implant loading, as well as to determine the effect of some of the factors on the stability of implants. Materials and Methods: Forty implants were inserted in 37 patients in the posterior mandibular region according to conventional protocol and allowed to heal by placing a healing abutment at the time of placement. For each implant, ITV was measured at the time of the implant placement by manual torque wrench (Nobel Biocare), and the ISQ value was measured by using resonance frequency analyzer (Osstell-ISQ; Integration Diagnostics) at the baseline levels, 3rd week, 7th week, 11th week, and 15th week interval. Results: The correlation between ITV and ISQ was found to be moderately positive and significant (r = 0.399) (P = 0.000). The correlation of ITV value at baseline and ISQ values recorded at the subsequent weeks was also found to be statistically significant at week 3 (r = 0.376) (P = 0.000) and week 7 (r = 0.327) (P = 0.000). Conclusion: It can be concluded from this study that there is a positive and statistically significant correlation between the ITV and ISQ values.
引用
收藏
页码:139 / 146
页数:8
相关论文
共 36 条
  • [21] The Influence of Low Insertion Torque on Primary Stability, Implant Survival, and Maintenance of Marginal Bone Levels: A Closed-Cohort Prospective Study
    Norton, Michael R.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) : 849 - 857
  • [22] Correlation between Implant Geometry, Bone Density, and the Insertion Torque/Depth Integral: A Study on Bovine Ribs
    Di Stefano, Danilo Alessio
    Arosio, Paolo
    Perrotti, Vittoria
    Iezzi, Giovanna
    Scarano, Antonio
    Piattelli, Adriano
    DENTISTRY JOURNAL, 2019, 7 (01)
  • [23] Influence of implant length and insertion depth on primary stability of short dental implants: An in vitro study of a novel mandibular artificial bone model
    Wu, Hsiang-Chun
    Huang, Heng-Li
    Fuh, Lih-Jyh
    Tsai, Ming-Tzu
    Hsu, Jui-Ting
    JOURNAL OF DENTAL SCIENCES, 2024, 19 (01) : 139 - 147
  • [24] A Comparative Study of Crestal Bone Loss and Implant Stability between Osteotome and Conventional Implant Insertion Techniques: A Randomized Controlled Clinical Trial Study
    Shayesteh, Yadollah Soleimani
    Khojasteh, Arash
    Siadat, Hakimeh
    Monzavi, Abbas
    Bassir, Seyed Hossein
    Hossaini, Mehran
    Alikhasi, Marzieh
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (03) : 350 - 357
  • [25] Correlation between implant stability quotient and bone-implant contact: A retrospective histological and histomorphometrical study of seven titanium implants retrieved from humans
    Scarano, Antonio
    Degidi, Marco
    Iezzi, Giovanna
    Petrone, Giovanna
    Piattelli, Adriano
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2006, 8 (04) : 218 - 222
  • [26] Assessment of Relationships Between Implant Insertion Torque and Cortical Shape of the Mandible Using Panoramic Radiography: Preliminary Study
    Tsukioka, Tsuneyuki
    Sasaki, Yusuke
    Kaneda, Takashi
    Buch, Karen
    Sakai, Osamu
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (03) : 622 - 626
  • [27] Relationship between implant primary stability (torque and ISQ) and bone density assessed by CBCT-clinical trial
    Gomes, R. Z.
    Lopes da Silva, L.
    Coimbra, J.
    Guerra, I.
    Vasconcelos, M.
    Correia, A.
    Braga, A. C.
    BIODENTAL ENGINEERING III, 2014, : 125 - 130
  • [28] Correlation between Initial BIC and the Insertion Torque/Depth Integral Recorded with an Instantaneous Torque-Measuring Implant Motor: An in vivo Study
    Cappare, Paolo
    Vinci, Raffaele
    Di Stefano, Danilo Alessio
    Traini, Tonino
    Pantaleo, Giuseppe
    Gherlone, Enrico Felice
    Gastaldi, Giorgio
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 : E613 - E620
  • [29] The insertion torque-depth curve integral as a measure of implant primary stability: An in vitro study on polyurethane foam blocks
    Di Stefano, Danilo Alessio
    Arosio, Paolo
    Gastaldi, Giorgio
    Gherlone, Enrico
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (05) : 706 - 714
  • [30] Influence of Implant Geometry on Primary Insertion Stability and Simulated Pen-implant Bone Loss: An In Vitro Study Using Resonance Frequency Analysis and Damping Capacity Assessment
    Lachmann, Stefan
    Laval, Johannes Yves
    Axmann, Detlef
    Weber, Heiner
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (02) : 347 - 355