Factors influencing validation of ambulatory blood pressure measuring devices

被引:0
|
作者
OBrien, E [1 ]
Atkins, N [1 ]
Staessen, J [1 ]
机构
[1] UNIV ZIEKENHUIS GASTHUISBERG,INWENDIGE GENEESKUNDE CARDIOL,KLIN LAB HYPERTENS,LOUVAIN,BELGIUM
关键词
ambulatory blood pressure; devices; validation; AAMI; BHS; protocols;
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
With the introduction of 24 h ambulatory blood pressure monitoring into clinical practice a vast market for ambulatory blood pressure monitoring devices has been created. To satisfy this market manufacturers are producing an array of ambulatory blood pressure monitoring devices. There is no obligation on manufacturers to have such devices validated independently, even though two national protocols, one from the British Hypertension Society (BHS) and the other from the Association for the Advancement of Medical Instrumentation (AAMI), call for independent validation and state the means of doing so. However, many factors can influence the validation procedure. They include compliance to the protocol being employed; the accuracy of the standard; establishing precisely the model being validated; the influences of blood pressure level, age and exercise on device accuracy; the provisions necessary for special populations, such as pregnant women, the elderly and children; the influence of oscillometric versus Korotkoff sound detection and electrocardiographic gating on comparative measurements; the assessment of performance as distinct from accuracy; and the relevance of general factors, such as the algorithm being employed and computer compatibility. Forty-three ambulatory blood pressure monitoring devices have been marketed for ambulatory blood pressure measurement and of those only 18 have been validated according to either the BHS or the AAMI protocol. The influence of the factors listed above on the validation studies of those devices will be considered and the relevance of validation procedures to the clinical use of ambulatory blood pressure monitoring devices will be discussed.
引用
收藏
页码:1235 / 1240
页数:6
相关论文
共 50 条
  • [21] Validation of digital devices for measuring blood pressure in Peru: a call for regulatory action
    Chavez-Ecos, Fabian A.
    Parra-Huaroto, Alexander
    Uribe-Cavero, Leonardo J.
    Anchante-Hernandez, Henry
    Toro-Huamanchumo, Carlos J.
    REVISTA PANAMERICANA DE SALUD PUBLICA-PAN AMERICAN JOURNAL OF PUBLIC HEALTH, 2024, 48
  • [22] Validation protocols for blood pressure measuring devices in the 21st century
    Stergiou, George S.
    Alpert, Bruce S.
    Mieke, Stephan
    Wang, Jiguang
    O'Brien, Eoin
    JOURNAL OF CLINICAL HYPERTENSION, 2018, 20 (07): : 1096 - 1099
  • [23] Accurate blood pressure measuring devices: Influencing users in the 21st century
    O'Brien, Eoin
    Alpert, Bruce S.
    Stergiou, George S.
    JOURNAL OF CLINICAL HYPERTENSION, 2018, 20 (07): : 1138 - 1141
  • [24] A Comparison of Blood Pressure Data Obtained From Wearable, Ambulatory, and Home Blood Pressure Monitoring Devices: Prospective Validation Study
    Islam, Sheikh Mohammed Shariful
    Maddison, Ralph
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2020, 22 (11)
  • [25] Validation of self blood pressure devices
    de Gaudemaris, R
    Asmar, R
    Girerd, X
    Mallion, JM
    Maitre, A
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 2000, 93 (08): : 979 - 982
  • [26] STRIDE BP SYSTEMATIC REVIEW OF PUBLISHED VALIDATION STUDIES OF BLOOD PRESSURE MEASURING DEVICES
    Menti, Ariadni
    Mariglis, Dimitrios
    Kyriakoulis, Konstantinos
    Kollias, Anastasios
    Palatini, Paolo
    Parati, Gianfranco
    Wang, Jiguang
    Schutte, Aletta
    Stergiou, George
    JOURNAL OF HYPERTENSION, 2024, 42 (SUPPL 3)
  • [27] Factors influencing blood pressure levels
    Zanchetti, Alberto
    JOURNAL OF HYPERTENSION, 2015, 33 (08) : 1497 - 1498
  • [28] THE NEED FOR A STANDARDIZED PROTOCOL FOR VALIDATING NON-INVASIVE AMBULATORY BLOOD-PRESSURE MEASURING DEVICES
    OBRIEN, E
    OMALLEY, K
    SHERIDAN, J
    JOURNAL OF HYPERTENSION, 1989, 7 : S19 - S20
  • [29] Factors influencing the blood pressure variability
    Adamkiewicz-Piejko, A
    Grodzicki, T
    Wizner, B
    Stolarz, K
    Zyczkowska, J
    Olszanecka, A
    Lubaszewski, W
    Kawecka-Jaszcz, K
    JOURNAL OF HYPERTENSION, 2004, 22 : S376 - S376
  • [30] COLLOID OSMOTIC-PRESSURE OF THE BLOOD - PHYSIOLOGY, MEASURING TECHNIQUE AND PREANALYTIC INFLUENCING FACTORS
    RETZKE, U
    GRAF, H
    ZENTRALBLATT FUR GYNAKOLOGIE, 1991, 113 (18): : 1005 - 1014