IMPACT OF APPARENT REACTANCE INJECTED BY TCSR ON DISTANCE RELAY IN PRESENCE PHASE TO EARTH FAULT

被引:6
作者
Zellagui, Mohamed [1 ]
Chaghi, Abdelaziz [1 ]
机构
[1] Univ Batna, Fac Technol, Dept Elect Engn, LSP IE Res Lab, Campus CUB,St Med el Hadi Boukhlouf, Batna 05000, Algeria
关键词
Apparent reactance; distance protection; earth fault; measured impedance; symmetrical components; TCSR; transmission line;
D O I
10.15598/aeee.v11i3.757
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This research paper presents the impact study of apparent reactance injected by series Flexible AC Transmission System (FACTS) i.e. Thyristor Controlled Series Reactor (TCSR) on the measured impedance of a 400 kV single electrical transmission line in the presence of phase to earth fault with fault resistance. The study deals with an electrical transmission line of Eastern Algerian transmission networks at Group Sonelgaz (Algerian Company of Electrical) compensated by TCSR connected at the midpoint of the transmission line. This compensator used to inject voltage and reactive power is controlled by TCSR. The simulations results investigate the three impacts of the apparent reactance injected by TCSR (XTcsR) on transmission line protected by distance relay protection. The impacts concern the active and reactive power, the line impedance (reactance and resistance), and the short circuit parameters (symmetrical currents, line currents, symmetrical voltages and line voltages as well as the measured impedance by relay (resistance and reactance) in the presence of earth fault These impacts are investigated in order to improve the performances of distance relay protection. More the impact of XTCSR by three TCSR for cases studies is presented.
引用
收藏
页码:156 / 168
页数:13
相关论文
共 31 条
  • [1] [Anonymous], 2009, 1534 IEEE
  • [2] Apparent impedance calculations for distance-protected transmission lines employing series-connected FACTS devices
    Dash, PK
    Pradhan, AK
    Panda, G
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2001, 29 (07) : 577 - 595
  • [3] A MHO distance relay device in EMTPWorks
    Gerin-Lajoie, Luc
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2009, 79 (03) : 484 - 491
  • [4] Group Sonelgaz/GRTE, 2012, TOP EL NETW 400 KV
  • [5] Group Sonelgaz/OS, 2012, RAPP STAT FAULTS EL
  • [6] Ha HX, 2004, 2004 International Conference on Power System Technology - POWERCON, Vols 1 and 2, P1
  • [7] Jamali A. e. H. S, 2008, MEASURED IMPEDANCE D
  • [8] Locus of apparent impedance of distance protection in the presence of SSSC
    Jamali, S.
    Shateri, H.
    [J]. EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2011, 21 (01): : 398 - 412
  • [9] Jamali S., 2008, Institution of Engineering and Technology 9th International Conference on Developments in Power Systems Protection, DPSP 2008, P553
  • [10] Jamali S., 2009, IEEE BUCH POW TECH C, P1, DOI DOI 10.1109/PSCE.2009.4840123