DYNAMIC SECURITY CONSTRAINED MULTIAREA UNIT COMMITMENT

被引:37
|
作者
HSU, YY
SU, CC
LIANG, CC
LIN, CJ
HUANG, CT
机构
[1] TAIWAN POWER CO,DEPT SYST OPERAT,TAIPEI,TAIWAN
[2] TAIWAN POWER CO,DEPT SYST PLANNING,TAIPEI,TAIWAN
关键词
DYNAMIC STABILITY; ECONOMIC OPERATION; UNIT COMMITMENT; DYNAMIC SECURITY;
D O I
10.1109/59.119245
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper presents a new approach for multi-area unit commitment which takes power system dynamic stability limit into account. In the proposed dynamic security constrained commitment method, dynamic programming is first employed to perform unit commitment on the whole system. The eigenvalues for the resultant hourly generation schedules are examined to see if they satisfy the prespecified dynamic security criterion. If the dynamic security requirement is not met at certain hours, an iterative algorithm is employed to reduce the inter-area line flows gradually and to perform area redispatch and, if necessary, area unit commitment, in order for the resultant generation schedule to satisfy the dynamic security requirement. The goal of the presented approach is to achieve a multi-area generation schedule which not only meets the conventional requirements of having lowest fuel costs with the spinning reserves and steady-state transmission capacity limits satisfied, but also offers good dynamic performance through the enforcement of dynamic security constraint. The effectiveness of the proposed approach is demonstrated by unit commitment of a utility system.
引用
收藏
页码:1049 / 1055
页数:7
相关论文
共 50 条
  • [31] HEURISTIC MULTIAREA UNIT COMMITMENT WITH ECONOMIC-DISPATCH
    OUYANG, Z
    SHAHIDEHPOUR, SM
    IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1991, 138 (03) : 242 - 252
  • [32] Security Constrained Unit Commitment with Phase Shifter and Wind Generation
    Daneshi, H.
    Srivastava, A. K.
    Daneshi, A.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [33] A security constrained unit commitment model based on immune algorithm
    Wang, Minwei
    Yang, Li
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (22): : 57 - 61
  • [34] Fast Simultaneous Feasibility Test for Security Constrained Unit Commitment
    Holzer, Jesse T.
    Chen, Yonghong
    Wu, Zhongyu
    Pan, Feng
    Veeramany, Arun
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2024, 39 (01) : 1068 - 1078
  • [35] Security constrained unit commitment:: Network modeling and solution issues
    Pinto, H.
    Magnago, F.
    Brignone, S.
    Alsac, O.
    Stott, B.
    2006 IEEE/PES POWER SYSTEMS CONFERENCE AND EXPOSITION. VOLS 1-5, 2006, : 1759 - +
  • [36] Web- based security constrained unit commitment system
    1 Decembrie 1918 University of Alba Iulia, N.Iorga St. No.1 1, 510009, Alba Iulia, Romania
    不详
    1600, 370-374 (2006):
  • [37] Web-based security constrained unit commitment system
    Risteiu, Mircea
    Sturgul, John
    Ileana, Loan
    2006 IEEE-TTTC INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS, VOL 1, PROCEEDINGS, 2006, : 370 - +
  • [38] Frequency security constrained short-term unit commitment
    Lei, X
    Lerch, E
    Xie, CY
    ELECTRIC POWER SYSTEMS RESEARCH, 2002, 60 (03) : 193 - 200
  • [39] Event-Driven Security-Constrained Unit Commitment
    Eskandarpour, Rozhin
    Khodaei, Amin
    Lin, Jeremy
    2016 IEEE POWER & ENERGY SOCIETY INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE (ISGT), 2016,
  • [40] Optimal corrective security constrained unit commitment model and algorithm
    Wang, Yang
    Xia, Qing
    Zhu, Mingxiang
    Yang, Minghui
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2011, 35 (09): : 19 - 24