THE COMMERCIAL DEVELOPMENT OF PLANAR OPTICAL BIOSENSORS

被引:45
作者
ROBINSON, G
机构
[1] Serono Diagnostics Ltd., Woking, Surrey GU21 5JY, 21 Woking Business Park, Albert Dr.
关键词
OPTICAL BIOSENSORS; FIBER OPTICS; PLANAR OPTICAL STRUCTURES; IMMUNOSENSORS; INTEGRATED OPTICS;
D O I
10.1016/0925-4005(95)01660-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Optical biosensors have been researched in great depth using both fibre-based and planar sensors, yet all the optical biosensors that are commercially available utilize planar structures because of the ease of fabrication of such devices compared with optical fibres. The advantages of planar structures over fibres are discussed.
引用
收藏
页码:31 / 36
页数:6
相关论文
共 33 条
  • [1] ABDELLATIF MS, 1988, ANAL LETT, V21, P943
  • [2] ENZYME-BASED FIBER OPTIC SENSOR
    ARNOLD, MA
    [J]. ANALYTICAL CHEMISTRY, 1985, 57 (02) : 565 - 566
  • [3] HOMOGENEOUS AMPEROMETRIC IMMUNOASSAY FOR THEOPHYLLINE IN WHOLE-BLOOD
    ATHEY, D
    MCNEIL, CJ
    BAILEY, WR
    HAGER, HJ
    MULLEN, WH
    RUSSELL, LJ
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (9-10) : 415 - 419
  • [4] OPTICAL BIOSENSORS FOR IMMUNOASSAYS - THE FLUORESCENCE CAPILLARY-FILL DEVICE
    BADLEY, RA
    DRAKE, RAL
    SHANKS, IA
    SMITH, AM
    STEPHENSON, PR
    THOMAS, JDR
    [J]. PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES B-BIOLOGICAL SCIENCES, 1987, 316 (1176) : 143 - 160
  • [5] FIBER OPTIC EVANESCENT WAVE IMMUNOSENSORS FOR MEDICAL DIAGNOSTICS
    BLUESTEIN, BI
    WALCZAK, IM
    CHEN, SY
    [J]. TRENDS IN BIOTECHNOLOGY, 1990, 8 (06) : 161 - 168
  • [6] LACTOSE REPRESSOR-OPERATOR DNA INTERACTIONS - KINETIC-ANALYSIS BY A SURFACE-PLASMON RESONANCE BIOSENSOR
    BONDESON, K
    FROSTELLKARLSSON, A
    FAGERSTAM, L
    MAGNUSSON, G
    [J]. ANALYTICAL BIOCHEMISTRY, 1993, 214 (01) : 245 - 251
  • [7] THE RESONANT MIRROR - A NOVEL OPTICAL SENSOR FOR DIRECT SENSING OF BIOMOLECULAR INTERACTIONS .2. APPLICATIONS
    BUCKLE, PE
    DAVIES, RJ
    KINNING, T
    YEUNG, D
    EDWARDS, PR
    POLLARDKNIGHT, D
    LOWE, CR
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (7-8) : 355 - 363
  • [8] ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
    CLARK, LC
    LYONS, C
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) : 29 - &
  • [9] THE RESONANT MIRROR - A NOVEL OPTICAL BIOSENSOR FOR DIRECT SENSING OF BIOMOLECULAR INTERACTIONS .1. PRINCIPLE OF OPERATION AND ASSOCIATED INSTRUMENTATION
    CUSH, R
    CRONIN, JM
    STEWART, WJ
    MAULE, CH
    MOLLOY, J
    GODDARD, NJ
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (7-8) : 347 - 353
  • [10] GIAEVER I, 1973, J IMMUNOL, V110, P1424