QUANTITATIVE E 3-DIMENSIONAL ASSESSMENT OF FACELIFT WITH AN OPTICAL FACIAL SURFACE SCANNER

被引:31
作者
VANNIER, MW [1 ]
PILGRAM, TK [1 ]
BHATIA, G [1 ]
BRUNSDEN, B [1 ]
NEMECEK, JR [1 ]
YOUNG, VL [1 ]
机构
[1] WASHINGTON UNIV,SCH MED,DIV PLAST SURG,ST LOUIS,MO 63110
关键词
D O I
10.1097/00000637-199303000-00002
中图分类号
R61 [外科手术学];
学科分类号
摘要
Three-dimensional computed tomographic scan images of facial deformities provide information that has been useful in planning and evaluating therapy. However, the benefits of computed tomographic imaging in cosmetic plastic surgery are often insufficient to justify exposing the patient to radiation. This report describes application of an optical, noncontact, three-dimensional surface digitizer with subsecond scanning time for 360-degree examination of the human head. The resultant three-dimensional surface data are suitable for computer graphics display and manipulation, and for noncontact skin surface measurement. The scanner provides accurate and complete coverage of complex facial surfaces. This system was applied to digitization of the human head in the planning and evaluation of facial plastic surgery. The results indicate that the resulting image is accurate enough to detect subtle dimensional changes resulting from surgery, including postoperative edema and surface changes due to face-lift. This type of scanning can assist in a number of tasks performed by plastic surgeons, including collecting anthropomorphic measurements, preoperative and postoperative assessment, volume monitoring, customizing of implants, and interactive planning.
引用
收藏
页码:204 / 211
页数:8
相关论文
共 12 条
[1]  
BAE KT, 1990, SPIE BIOSTEREOMETR, V1380, P171
[2]   3-DIMENSIONAL INPUT OF BODY-SURFACE DATA USING A LASER-LIGHT SCANNER [J].
CUTTING, CB ;
MCCARTHY, JG ;
KARRON, DB .
ANNALS OF PLASTIC SURGERY, 1988, 21 (01) :38-45
[3]  
CUTTING CB, 1991, 3D IMAGING MED, P163
[4]  
GRINDON JR, 1989, NAT COMPUTER GRAPHIC, V1, P132
[5]  
KAFRI O, 1990, PHYSICS MOIRE METROL
[6]   A COMPUTER-SYSTEM FOR THE INTERACTIVE PLANNING AND PREDICTION OF MAXILLOFACIAL SURGERY [J].
MOSS, JP ;
GRINDROD, SR ;
LINNEY, AD ;
ARRIDGE, SR ;
JAMES, D .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1988, 94 (06) :469-475
[7]   ANALYZE - A COMPREHENSIVE, OPERATOR-INTERACTIVE SOFTWARE PACKAGE FOR MULTIDIMENSIONAL MEDICAL IMAGE DISPLAY AND ANALYSIS [J].
ROBB, RA ;
HANSON, DP ;
KARWOSKI, RA ;
LARSON, AG ;
WORKMAN, EL ;
STACY, MC .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1989, 13 (06) :433-454
[8]  
SADLER LL, 1990, SPIE BIOSTEREOMETR T, V1380, P158
[9]  
TRINDER JC, 1990, SPIE CLOSE RANGE PHO, V1395, P440
[10]   FACIAL SURFACE SCANNER [J].
VANNIER, MW ;
PILGRAM, T ;
BHATIA, G ;
BRUNSDEN, B ;
COMMEAN, P .
IEEE COMPUTER GRAPHICS AND APPLICATIONS, 1991, 11 (06) :72-80