ASSAY OF NEOPTERIN IN SERUM BY MEANS OF 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH AUTOMATED COLUMN-SWITCHING USING 3 RETENTION MECHANISMS

被引:9
|
作者
HUBER, JFK [1 ]
LAMPRECHT, G [1 ]
机构
[1] UNIV VIENNA,INST ANALYT CHEM,A-1090 VIENNA,AUSTRIA
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1995年 / 666卷 / 02期
关键词
D O I
10.1016/0378-4347(94)00568-P
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An automated two-dimensional HPLC method for the determination of neopterin in serum is described. Neopterin is separated from proteins on a short octadecylsilica column by size exclusion and from the majority of the other serum components by adsorption. The fraction containing neopterin is transferred by column switching to a solvent-generated cation-exchange column using dodecylsulfonic acid as surface activator. Parameters influencing the separation performance and sensitivity of the fluorescence detection are discussed. The efficiency of the cleaning of the first column was optimized. The method was validated. It achieves a precision of 1% (R.S.D.) and a detection limit of about 0.3 nmol/l. The accuracy is nearly 100%. The method allows a high sample throughput, requiring 15 min per sample.
引用
收藏
页码:223 / 232
页数:10
相关论文
共 50 条
  • [31] Column-switching high-performance liquid chromatographic assay for minocycline of nude mice serum
    Bompadre, S
    Ferrante, L
    Leone, L
    Montesi, M
    Possati, L
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1997, 20 (08) : 1257 - 1267
  • [32] ROUTINE DETERMINATION OF HYDROXYPHENYTOIN IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING AN AUTOMATIC COLUMN-SWITCHING TECHNIQUE
    JURGENS, U
    JOURNAL OF CHROMATOGRAPHY, 1983, 275 (02): : 335 - 343
  • [33] DIRECT INJECTION-ANALYSIS OF MELPHALAN IN PLASMA USING COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KATO, Y
    KANEKO, H
    MATSUSHITA, T
    INAMORI, K
    EGI, S
    TOGAWA, A
    YOKOYAMA, T
    MOHRI, K
    THERAPEUTIC DRUG MONITORING, 1992, 14 (01) : 66 - 71
  • [34] DIRECT ANALYSIS FOR COCAINE IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY (HPLC) USING A COLUMN-SWITCHING TECHNIQUE
    LARSEN, AK
    TEBBETT, IR
    JOURNAL OF FORENSIC SCIENCES, 1992, 37 (02) : 636 - 639
  • [35] DETERMINATION OF CICLETANINE IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING AUTOMATED COLUMN SWITCHING
    ANTONIEWICZ, SM
    COOK, JA
    BROWN, RR
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 573 (01): : 93 - 98
  • [36] DETERMINATION OF AN ALDOSTERONE ANTAGONIST IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING AUTOMATED COLUMN SWITCHING
    TIMM, U
    SANER, A
    JOURNAL OF CHROMATOGRAPHY, 1986, 378 (01): : 25 - 34
  • [37] IMPROVEMENTS IN AUTOMATED-ANALYSIS OF CATECHOLAMINE AND RELATED METABOLITES IN BIOLOGICAL SAMPLES BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    GROSSI, G
    BARGOSSI, AM
    LUCARELLI, C
    PARADISI, R
    SPROVIERI, C
    SPROVIERI, G
    JOURNAL OF CHROMATOGRAPHY, 1991, 541 (1-2): : 273 - 284
  • [38] AUTOMATED-DETERMINATION OF DRUGS IN SERUM BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .4. SEPARATION OF TRICYCLIC AND TETRACYCLIC ANTIDEPRESSANTS AND THEIR METABOLITES
    MATSUMOTO, K
    KANBA, S
    KUBO, H
    YAGI, G
    IRI, H
    YUKI, H
    CLINICAL CHEMISTRY, 1989, 35 (03) : 453 - 456
  • [39] Automated column-switching high-performance liquid chromatography for the determination of aflatoxin M1
    Simon, P
    Delsaut, P
    Lafontaine, M
    Morele, Y
    Nicot, T
    JOURNAL OF CHROMATOGRAPHY B, 1998, 712 (1-2): : 95 - 104
  • [40] DETERMINATION OF OFLOXACIN IN HUMAN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN SWITCHING
    OHKUBO, T
    KUDO, M
    SUGAWARA, K
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 573 (02): : 289 - 293