ASSAY OF NEOPTERIN IN SERUM BY MEANS OF 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH AUTOMATED COLUMN-SWITCHING USING 3 RETENTION MECHANISMS

被引:9
|
作者
HUBER, JFK [1 ]
LAMPRECHT, G [1 ]
机构
[1] UNIV VIENNA,INST ANALYT CHEM,A-1090 VIENNA,AUSTRIA
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1995年 / 666卷 / 02期
关键词
D O I
10.1016/0378-4347(94)00568-P
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An automated two-dimensional HPLC method for the determination of neopterin in serum is described. Neopterin is separated from proteins on a short octadecylsilica column by size exclusion and from the majority of the other serum components by adsorption. The fraction containing neopterin is transferred by column switching to a solvent-generated cation-exchange column using dodecylsulfonic acid as surface activator. Parameters influencing the separation performance and sensitivity of the fluorescence detection are discussed. The efficiency of the cleaning of the first column was optimized. The method was validated. It achieves a precision of 1% (R.S.D.) and a detection limit of about 0.3 nmol/l. The accuracy is nearly 100%. The method allows a high sample throughput, requiring 15 min per sample.
引用
收藏
页码:223 / 232
页数:10
相关论文
共 50 条
  • [1] DETERMINATION OF BROMPERIDOL IN SERUM BY AUTOMATED COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HIKIDA, K
    INOUE, Y
    MIYAZAKI, T
    KOJIMA, N
    OHKURA, Y
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 495 : 227 - 234
  • [2] AUTOMATED-ANALYSIS OF ANTIEPILEPTIC DRUGS IN SERUM BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    NAZARETH, A
    JARAMILLO, L
    KARGER, BL
    GIESE, RW
    SNYDER, LR
    JOURNAL OF CHROMATOGRAPHY, 1984, 309 (02): : 357 - 368
  • [3] DETERMINATION OF RETINOIDS IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND AUTOMATED COLUMN-SWITCHING
    WYSS, R
    METHODS IN ENZYMOLOGY, 1990, 189 : 146 - 155
  • [4] AUTOMATED-DETERMINATION OF FLUVOXAMINE IN PLASMA BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HARTTER, S
    WETZEL, H
    HIEMKE, C
    CLINICAL CHEMISTRY, 1992, 38 (10) : 2082 - 2086
  • [5] AUTOMATED-DETERMINATION OF MIDAZOLAM IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING COLUMN-SWITCHING
    LAUBER, R
    MOSIMANN, M
    BUHRER, M
    ZBINDEN, AM
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 654 (01): : 69 - 75
  • [6] AUTOMATED-DETERMINATION OF HYPOXANTHINE AND XANTHINE IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING
    SUMI, S
    KIDOUCHI, K
    OHBA, S
    WADA, Y
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 670 (02): : 376 - 378
  • [7] DETERMINATION OF CLOCAPRAMINE AND ITS METABOLITES IN PLASMA BY AUTOMATED COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HIKIDA, K
    INOUE, Y
    KOJIMA, N
    OHKURA, Y
    ANALYTICAL SCIENCES, 1990, 6 (03) : 367 - 370
  • [8] AUTOMATED-DETERMINATION OF DRUGS IN SERUM BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .2. SEPARATION OF THEOPHYLLINE AND ITS METABOLITES
    MATSUMOTO, K
    KIKUCHI, H
    IRI, H
    TAKAHASI, H
    UMINO, M
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 425 (02): : 323 - 330
  • [9] DETERMINATION OF OXYTETRACYCLINE IN FISH PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND COLUMN-SWITCHING
    EIVINDVIK, K
    RASMUSSEN, KE
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1989, 12 (15): : 3061 - 3071
  • [10] ANALYSIS OF A COMPLEX ANALGESIC FORMULATION BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING
    COCKAERTS, P
    ROETS, E
    HOOGMARTENS, J
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1986, 4 (03) : 367 - 376