Effects of gamma irradiation on the biomechanical properties of peroneus tendons

被引:7
作者
Aguila, Christopher M. [1 ]
Delcroix, Gaetan J-R [2 ,3 ,4 ,5 ,6 ]
Kaimrajh, David N. [7 ]
Milne, Edward L. [7 ]
Temple, H. Thomas [6 ]
Latta, Loren L. [2 ,7 ]
机构
[1] Florida Int Univ, Dept Biol Sci, Miami, FL 33199 USA
[2] Univ Miami, Miller Sch Med, Dept Orthopaed, Miami, FL 33136 USA
[3] Bruce W Carter Vet Affairs Med Ctr, Res Serv, Miami, FL USA
[4] Bruce W Carter Vet Affairs Med Ctr, Geriatr Res Educ & Clin Ctr, Miami, FL USA
[5] Univ Miami, Interdisciplinary Stem Cell Inst, Miami, FL USA
[6] Vivex Biomed Inc, Marietta, GA USA
[7] Max Biedermann Inst Biomech, Miami Beach, FL USA
关键词
ACL reconstruction; allograft; sterilization; tissue banking;
D O I
10.2147/OAJSM.S109156
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: This study was designed to investigate the biomechanical properties of nonirradiated (NI) and irradiated (IR) peroneus tendons to determine if they would be suitable allografts, in regards to biomechanical properties, for anterior cruciate ligament reconstruction after a dose of 1.5-2.5 Mrad. Methods: Seven pairs of peroneus longus (PL) and ten pairs of peroneus brevis (PB) tendons were procured from human cadavers. The diameter of each allograft was measured. The left side of each allograft was IR at 1.5-2.5 Mrad, whereas the right side was kept aseptic and NI. The allografts were thawed, kept wet with saline, and attached in a single-strand fashion to custom freeze grips using liquid nitrogen. A preload of 10 N was then applied and, after it had reached steady state, the allografts were pulled at 4 cm/sec. The parameters recorded were the displacement and force. Results: The elongation at the peak load was 10.3 +/- 2.3 mm for the PB NI side and 13.5 +/- 3.3 mm for the PB IR side. The elongation at the peak load was 17.4 +/- 5.3 mm for the PL NI side and 16.3 +/- 2.0 mm for the PL IR side. For PL, the ultimate load was 2,091.6 +/- 148.7 N for NI and 2,122.8 +/- 380.0 N for IR. The ultimate load for the PB tendons was 1,485.7 +/- 209.3 N for NI and 1,318.4 +/- 296.9 N for the IR group. The ultimate stress calculations for PL were 90.3 +/- 11.3 MPa for NI and 94.8 +/- 21.0 MPa for IR. For the PB, the ultimate stress was 82.4 +/- 19.0 MPa for NI and 72.5 +/- 16.6 MPa for the IR group. The structural stiffness was 216.1 +/- 59.0 N/mm for the NI PL and 195.7 +/- 51.4 N/mm for the IR side. None of these measures were significantly different between the NI and IR groups. The structural stiffness was 232.1 +/- 45.7 N/mm for the NI PB and 161.9 +/- 74.0 N/mm for the IR side, and this was the only statistically significant difference found in this study (P=0.034). Conclusion: Our statistical comparisons found no significant differences in terms of elongation, ultimate load, or ultimate stress between IR and NI PB and PL tendons. Only the PB structural stiffness was affected by irradiation. Thus, sterilizing allografts at 1.5-2.5 Mrad of gamma irradiation does not cause major alterations in the tendons' biomechanical properties while still providing a suitable amount of sterilization for anterior cruciate ligament reconstruction.
引用
收藏
页码:123 / 127
页数:5
相关论文
共 22 条
[1]  
[Anonymous], 2014, AM AC ORTH SURG MARC
[2]  
[Anonymous], 2013, AM ORTH SOC SPORT ME
[3]   A Biomechanical Comparison of Fan-Folded, Single-Looped Fascia Lata With Other Graft Tissues as a Suitable Substitute for Anterior Cruciate Ligament Reconstruction [J].
Chan, Daniel B. ;
Temple, H. Thomas ;
Latta, Loren L. ;
Mahure, Siddharth ;
Dennis, Jeremy ;
Kaplan, Lee D. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (12) :1641-1647
[4]   Effects of ionizing radiation on the mechanical properties of human bone [J].
Currey, JD ;
Foreman, J ;
Laketic, I ;
Mitchell, J ;
Pegg, DE ;
Reilly, GC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (01) :111-117
[5]   Histologic, Biomechanical, and Biological Evaluation of Fan-Folded Iliotibial Band Allografts for Anterior Cruciate Ligament Reconstruction [J].
Delcroix, Gaetan J-R. ;
Kaimrajh, David N. ;
Baria, Dinah ;
Cooper, Sonya ;
Reiner, Teresita ;
Latta, Loren ;
D'Ippolito, Gianluca ;
Schiller, Paul C. ;
Temple, H. Thomas .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2013, 29 (04) :756-765
[6]   GAMMA-IRRADIATION - EFFECTS ON BIOMECHANICAL PROPERTIES OF HUMAN BONE-PATELLAR TENDON-BONE ALLOGRAFTS [J].
FIDELER, BM ;
VANGSNESS, T ;
LU, B ;
ORLANDO, C ;
MOORE, T .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1995, 23 (05) :643-646
[7]  
Friedberg R., 2015, ANTERIOR CRUCIATE LI
[8]  
HAUT RC, 1989, T ORTHOP RES SOC, V14, P514
[9]  
Health USFaDACfDaR, 2002, MED DEV UPD 510K STE
[10]   Fractionation of high-dose electron beam irradiation of BPTB grafts provides significantly improved viscoelastic and structural properties compared to standard gamma irradiation [J].
Hoburg, A. ;
Keshlaf, S. ;
Schmidt, T. ;
Smith, M. ;
Gohs, U. ;
Perka, C. ;
Pruss, A. ;
Scheffler, S. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (11) :1955-1961