A POSITION-SENSITIVE IONIZATION-CHAMBER FOR MEASUREMENT OF FISSION FRAGMENTS AND MEDIUM MASS HEAVY-IONS

被引:10
作者
BISWAS, DC [1 ]
AMBEKAR, VS [1 ]
PANT, LM [1 ]
DINESH, BV [1 ]
CHOUDHURY, RK [1 ]
机构
[1] BARC,DIV NUCL PHYS,BOMBAY 400085,INDIA
关键词
D O I
10.1016/0168-9002(94)90137-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A position sensitive ionisation chamber telescope is described with DELTAE(gas)-Eg.s sections which can measure simultaneously the specific energy loss DELTAE, energy E and the position of heavy ion reaction products in the median plane. The position information is derived by having a split DELTAE structure and by adopting the pulse division method for the signals collected by the two DELTAE sections. For on-line angle calibration, the E-part of the anode structure is also split into five segments. The detector was tested with fission fragments from a Cf-252 spontaneous fission source and with heavy ions from the pelletron tandem accelerator. Simultaneous measurement of DELTAE and E gives good separation for heavy and light fission fragment groups. The position resolution is found to be 1.1 mm for fission fragments. The detector has been used in heavy ion reaction studies for measuring fission fragments, providing good separation from projectile-like particles.
引用
收藏
页码:551 / 554
页数:4
相关论文
共 50 条
[21]   POSITION-SENSITIVE MULTIWIRE PROPORTIONAL CHAMBER FOR FISSION FRAGMENTS WITH LARGE SOLID ANGLE [J].
GLASSEL, P ;
ROSLER, H ;
MANNER, R ;
SPECHT, HJ .
NUCLEAR INSTRUMENTS & METHODS, 1977, 141 (01) :111-114
[22]   A LOW-PRESSURE MULTIWIRE PROPORTIONAL CHAMBER AS A POSITION-SENSITIVE DETECTOR OF HEAVY-IONS - CONSTRUCTION AND DETECTION PROPERTIES [J].
STAHLER, J ;
PRESSER, G .
NUCLEAR INSTRUMENTS & METHODS, 1980, 177 (2-3) :427-431
[23]   DELTA-E GAS IONIZATION-CHAMBER FOR FISSION FRAGMENTS [J].
AJITANAND, NN ;
KAPOOR, SS ;
KATARIA, SK ;
RAO, PNR .
NUCLEAR INSTRUMENTS & METHODS, 1972, 103 (01) :169-+
[24]   A position-sensitive ionization chamber for thermal neutrons [J].
Yu, B ;
Mahler, GJ ;
Schaknowski, NA ;
Smith, GC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) :336-340
[25]   Construction and commissioning of a position-sensitive ionization chamber [J].
M. S. Kwag ;
K. Y. Chae ;
S. M. Cha ;
A. Kim ;
M. J. Kim ;
E. J. Lee ;
J. H. Lee .
Journal of the Korean Physical Society, 2016, 68 :1165-1169
[26]   Construction and commissioning of a position-sensitive ionization chamber [J].
Kwag, M. S. ;
Chae, K. Y. ;
Cha, S. M. ;
Kim, A. ;
Kim, M. J. ;
Lee, E. J. ;
Lee, J. H. .
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 68 (10) :1165-1169
[27]   A position-sensitive twin ionization chamber for fission fragment and prompt neutron correlation experiments [J].
Gook, A. ;
Geerts, W. ;
Hambsch, F. -J. ;
Oberstedt, S. ;
Vidali, M. ;
Zeynalov, Sh. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 830 :366-374
[28]   ABSOLUTE MEASUREMENT OF 235-U MASS OF A LARGE VOLUME MULTIPLATED FISSION IONIZATION-CHAMBER [J].
WASSON, OA ;
MEIER, MM ;
GILLIAM, DM ;
SCHWARTZ, RB .
BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (04) :647-647
[29]   Position-sensitive spectroscopy of 252Cf fission fragments [J].
Granja, C. ;
Vykydal, Z. ;
Kopatch, Y. ;
Jakubek, J. ;
Pospisil, S. ;
Telezhnikov, S. A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 574 (03) :472-478
[30]   A TWO-DIMENSIONAL POSITION-SENSITIVE MWPC FOR FISSION FRAGMENTS [J].
VANDERPLICHT, J ;
GAVRON, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 211 (2-3) :403-406