ONLINE PRECONCENTRATION AND LIQUID-CHROMATOGRAPHIC ANALYSIS OF PHENYLUREA PESTICIDES IN ENVIRONMENTAL WATER USING A SILICA-BASED IMMUNOSORBENT

被引:44
作者
PICHON, V [1 ]
CHEN, L [1 ]
HENNION, MC [1 ]
机构
[1] ECOLE SUPER PHYS & CHIM IND VILLE PARIS,CHIM ANALYT LAB,CNRS,URA 437,F-75231 PARIS 05,FRANCE
关键词
LIQUID CHROMATOGRAPHY; IMMUNOASSAY; PRECONCENTRATION; PESTICIDES; PHENYLUREA PESTICIDES; ENVIRONMENTAL ANALYSIS;
D O I
10.1016/0003-2670(95)00160-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The feasibility of using a silica-based immunosorbent for the selective on-line preconcentration of several phenylurea pesticides in drinking and surface waters was demonstrated. The immunosorbent was packed in a precolumn which was used in the same way as a conventional C-18 or PLRP-S precolumn: percolation of aqueous samples through the precolumn, then direct coupling to a C-18 analytical column and desorption using an acetonitrile gradient from 20 to 80% acetonitrile. Although the retention of the different phenylureas was based on antigen-antibody interactions in the precolumn and on hydrophobic interactions in the analytical column, the efficiency of the on-line system was excellent as shown by the on-line preconcentration and analysis of 12 phenylureas of different polarities. The characteristics of the immunosorbent (cross-reactivity, breakthrough of analytes, capacity, selectivity and reusability) were discussed. An application to the analysis of surface waters showed the high selectivity of this sorbent. Detection limits from a 50-ml sample were ranging between 0.05 and 0.5 mu g/l for 10 phenylureas in a mixture of 13. An application to the rapid monitoring of isoproturon in the river Seine was also reported.
引用
收藏
页码:429 / 436
页数:8
相关论文
共 19 条
[1]   IMMUNOAFFINITY PRE-COLUMN FOR SELECTIVE ONLINE SAMPLE PRE-TREATMENT IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY DETERMINATION OF 19-NORTESTOSTERONE [J].
FARJAM, A ;
DEJONG, GJ ;
FREI, RW ;
BRINKMAN, UAT ;
HAASNOOT, W ;
HAMERS, ARM ;
SCHILT, R ;
HUF, FA .
JOURNAL OF CHROMATOGRAPHY, 1988, 452 :419-433
[2]   IMMUNO PRECOLUMNS FOR SELECTIVE ONLINE SAMPLE PRETREATMENT OF AFLATOXINS IN MILK PRIOR TO COLUMN LIQUID-CHROMATOGRAPHY [J].
FARJAM, A ;
DEVRIES, R ;
LINGEMAN, H ;
BRINKMAN, UAT .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1991, 44 (03) :175-184
[3]   NONSELECTIVE DESORPTION OF IMMUNO PRECOLUMNS COUPLED ONLINE WITH COLUMN LIQUID-CHROMATOGRAPHY - DETERMINATION OF AFLATOXINS [J].
FARJAM, A ;
VANDEMERBEL, NC ;
LINGEMAN, H ;
FREI, RW ;
BRINKMAN, UAT .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1991, 45 (02) :73-87
[4]  
FARJAM A, 1991, THESIS FREE U AMSTER
[5]   SOLID-PHASE EXTRACTION IN MULTI-RESIDUE PESTICIDE ANALYSIS OF WATER [J].
FONT, G ;
MANES, J ;
MOLTO, JC ;
PICO, Y .
JOURNAL OF CHROMATOGRAPHY, 1993, 642 (1-2) :135-161
[6]   DETERMINATION OF BETA-19-NORTESTOSTERONE AND ITS METABOLITE ALPHA-19-NORTESTOSTERONE IN BIOLOGICAL SAMPLES AT THE SUB PARTS PER BILLION LEVEL BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ONLINE IMMUNOAFFINITY SAMPLE PRETREATMENT [J].
HAASNOOT, W ;
SCHILT, R ;
HAMERS, ARM ;
HUF, FA ;
FARJAM, A ;
FREI, RW ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 489 (01) :157-171
[7]   HPLC ANALYSIS OF HUMAN EPIDERMAL GROWTH-FACTOR USING IMMUNOAFFINITY PRECOLUMN .1. OPTIMIZATION OF IMMUNOAFFINITY COLUMN [J].
HAYASHI, T ;
SAKAMOTO, S ;
SHIKANABE, M ;
WADA, I ;
YOSHIDA, H .
CHROMATOGRAPHIA, 1989, 27 (11-12) :569-573
[8]  
HENNION MC, 1993, ENV ANAL TECHNIQUES, P23
[9]  
JOHANSSON B, 1989, J CHROMATOGR, V381, P107
[10]  
NIELEN MWF, 1989, J CHROMATOGRAPHY L A, V39, P5