FOREIGN-BODY COMPLICATIONS OF CENTRAL VENOUS CATHETERIZATION IN CRITICALLY ILL PATIENTS

被引:9
作者
HEHIR, DJ
CROSS, KS
KIRKHAM, R
MOORE, DJ
SHANIK, DG
机构
[1] Departments of Vascular Surgery and Anaesthesia, St. James' Hospital and Trinity College, Dublin
关键词
D O I
10.1007/BF02942083
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In three critically ill patients, central venous catheter-associated foreign bodies were identified while the patients were in the intensive care unit. Two patients had fragments of retained catheter; in the third patient a guide-wire was lost within the vascular tree. The catheter fragments were associated with clinical symptoms while side effects were not observed with loss of the guide-wire. All three foreign bodies were removed without complications
引用
收藏
页码:49 / 51
页数:3
相关论文
共 16 条
[1]  
Grant J., Handbook of total parenteral nutrition, pp. 47-69, (1980)
[2]  
Eerola R., Kaukinen L., Kaukinen S., Analysis of 13,800 subclavian vein catheterisations. Acta Anaesthesiol, Scand., 29, pp. 193-197, (1985)
[3]  
Bernard R.W., Stahl W.M., Subclavian vein catheterisations: a prospective study, Ann. Surg., 173, pp. 184-190, (1970)
[4]  
Lybecker H., Andersen C., Hansen M.K., Transvenous retrieval of intracardiac catheter fragments, Acta Anaesth. Scand., 33, pp. 565-567, (1989)
[5]  
Seldinger S.I., Catheter replacement of the needle in percutaneous arteriography, Acta Radiol., 39, pp. 368-376, (1953)
[6]  
Grabenwoeger F., Bardach G., Dock W., Pinterits F., Percutaneous extraction of centrally embolized foreign bodies: a report of 16 cases, Br. J. Radiol., 61, pp. 1014-1018, (1988)
[7]  
Schou H., The double J-spring guide wire and its hazards. Partially retained double J-wire: a complication during central venous catheterisation, Acta Anaesthesiol. Scand., 32, pp. 158-160, (1988)
[8]  
Polos P.G., Sahn S.A., Complication of central venous catheter insertion: fragmentation of a guidewire with pulmonary artery embolism, Crit. Care Med., 19, pp. 438-440, (1991)
[9]  
Turner D.D., Sommers S.C., Accidental passage of a polyethylene catheter from cubital vein to right atrium, N. Eng. J. Med., 251, pp. 744-745, (1954)
[10]  
Thomas J., Sinclair-Smith B., Bloomfield D., Davachi A., Nonsurgical retrieval of a broken steel spring guide from right atrium and vena cava, Circulation, 30, pp. 106-108, (1964)