A PSEUDOEPIDEMIC OF MYCOBACTERIUM-CHELONAE - CONTAMINATION OF A BRONCHOSCOPE AND AUTOCLEANER

被引:22
作者
CAMPAGNARO, RL
TEICHTAHL, H
DWYER, B
机构
[1] WESTERN HOSP,DEPT RESP MED,MELBOURNE,VIC,AUSTRALIA
[2] FAIRFIELD HOSP,DEPT INFECT DIS,MELBOURNE,VIC,AUSTRALIA
来源
AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE | 1994年 / 24卷 / 06期
关键词
BRONCHOSCOPE; AUTOCLEANER; MCH CONTAMINATION; GLUTARALDEHYDE; STERILE WATER; ETHYLENE OXIDE;
D O I
10.1111/j.1445-5994.1994.tb01785.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: At fibreoptic bronchoscopy the potential exists for contamination of bronchoscopes and microbiological specimens. Patients may also be cross infected with acid fast bacilli (AFB). During a five month period, 12 bronchial wash specimens of 65 patients undergoing bronchoscopy, one bronchoscope and an autocleaner, were contaminated with the AFB, Mycobacterium chelonae (MCH). Aim: To eradicate AFB contamination of bronchoscopy specimens by identifying sources of contamination and modifying disinfection procedures. Methods: To identify the source of contamination, samples for AFB culture were taken from three bronchoscopes, the autocleaner and water taps. To eradicate MCH contamination, the bronchoscopes were soaked in 2% glutaraldehyde overnight and flushed with 70% alcohol. Disinfection procedures were altered by using sterile water and containers in cleaning. Autocleaner use was discontinued. Results: The autocleaner, one bronchoscope and 12 bronchial wash specimens were contaminated with MCH. All contaminants had similar electrophoretic banding on probing of their DNA fragments, suggesting a common clone of origin. After the alterations in disinfection procedures and despite prolonged soaking in 2% glutaraldehyde, three further contaminated wash specimens were isolated from one bronchoscope. Only after ethylene oxide sterilisation of this bronchoscope was the contamination overcome. Since then no further MCH contamination has occurred. No patient required treatment and there has been no clinical evidence of mycobacterial disease. Conclusion: To avoid contamination of bronchoscopy specimens with MCH, use of autocleaners should be discouraged and sterile water and containers used in cleaning procedures. If MCH contamination occurs in this setting, the bronchoscope and dismantled valve mechanism should undergo ethylene oxide sterilisation.
引用
收藏
页码:693 / 695
页数:3
相关论文
共 9 条
[1]   MYCOBACTERIA IN WATER [J].
COLLINS, CH ;
GRANGE, JM ;
YATES, MD .
JOURNAL OF APPLIED BACTERIOLOGY, 1984, 57 (02) :193-211
[2]   CONTAMINATION OF FLEXIBLE FIBEROPTIC BRONCHOSCOPES WITH MYCOBACTERIUM-CHELONAE LINKED TO AN AUTOMATED BRONCHOSCOPE DISINFECTION MACHINE [J].
FRASER, VJ ;
JONES, M ;
MURRAY, PR ;
MEDOFF, G ;
ZHANG, YS ;
WALLACE, RJ .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1992, 145 (04) :853-855
[3]   TRANSMISSION OF TUBERCULOSIS BY FLEXIBLE FIBERBRONCHOSCOPES [J].
NELSON, KE ;
LARSON, PA ;
SCHRAUFNAGEL, DE ;
JACKSON, J .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1983, 127 (01) :97-100
[4]   MYCOBACTERIUM-CHELONEI ISOLATION FROM BRONCHOALVEOLAR LAVAGE FLUID AND ITS PRACTICAL IMPLICATIONS [J].
NYE, K ;
CHADHA, DK ;
HODGKIN, P ;
BRADLEY, C ;
HANCOX, J ;
WISE, R .
JOURNAL OF HOSPITAL INFECTION, 1990, 16 (03) :257-261
[5]  
PAPPAS SA, 1983, AM REV RESPIR DIS, V127, P391
[6]   MOLECULAR-CLONING OF A HIGHLY REPEATED DNA ELEMENT FROM MYCOBACTERIUM-TUBERCULOSIS AND ITS USE AS AN EPIDEMIOLOGIC TOOL [J].
ROSS, BC ;
RAIOS, K ;
JACKSON, K ;
DWYER, B .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (04) :942-946
[7]   SUCCESSFUL TREATMENT OF PULMONARY INFECTION DUE TO MYCOBACTERIUM-CHELONAE - CASE-REPORT AND REVIEW [J].
SINGH, N ;
YU, VL .
CLINICAL INFECTIOUS DISEASES, 1992, 14 (01) :156-161
[8]   BRONCHOPULMONARY CROSS-COLONIZATION AND INFECTION RELATED TO MYCOBACTERIAL CONTAMINATION OF SUCTION VALVES OF BRONCHOSCOPES [J].
WHEELER, PW ;
LANCASTER, D ;
KAISER, AB .
JOURNAL OF INFECTIOUS DISEASES, 1989, 159 (05) :954-958
[9]  
WOODCOCK A, 1989, LANCET, V2, P270