CHARACTERIZATION OF IMMOBILINE MEMBRANES FOR APPLICATION IN A MULTICOMPARTMENT ELECTROLYZER FOR PROTEIN-PURIFICATION

被引:3
|
作者
CHERKAOUI, S
ZELL, P
JAVET, P
机构
[1] Swiss Federal Institute of Technology, Institute of Chemical Engineering, Laussane
来源
关键词
PREPARATIVE ISOELECTRIC FOCUSING; IMMOBILIZED PH GRADIENT; AMPHOTERIC IMMOBILINE MEMBRANE;
D O I
10.1016/0165-022X(92)90037-B
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The efficient use of preparative protein purification in a multicompartment electrolyzer with Immobiline membranes depends on the knowledge of membrane characteristics. For that purpose, an experimental investigation of the effects of ionic charges on the membrane characteristics has been carried out through the measurements of membrane swelling and conductance. We also investigated the effects on the electrolyzer behaviour of operating parameters such as the Immobiline concentration and the presence of ion-exchange membranes. Data show that polyacrylamide gel degree of swelling is strongly dependent upon the pH and the ionic strength of the bathing solution as well as on the type and molarity of charges incorporated in the gel. The conductance of supported Immobiline gels in contact with uni-univalent chloride solutions has been measured by means of a mercury cell. The membrane conductance is also influenced by the ionic strength of the equilibrium solution and the presence of weak ionizable groups in the gel matrix. This study has demonstrated the close link between electrochemical and electromechanical properties of Immobiline membranes.
引用
收藏
页码:61 / 73
页数:13
相关论文
共 50 条
  • [1] PREPARATIVE PROTEIN-PURIFICATION IN A MULTI-COMPARTMENT ELECTROLYZER WITH IMMOBILINE MEMBRANES
    RIGHETTI, PG
    WENISCH, E
    FAUPEL, M
    JOURNAL OF CHROMATOGRAPHY, 1989, 475 : 293 - 309
  • [2] CAPILLARY ZONE ELECTROPHORESIS FOR MONITORING R-DNA PROTEIN-PURIFICATION IN MULTICOMPARTMENT ELECTROLYSERS WITH IMMOBILINE MEMBRANES
    WENISCH, E
    TAUER, C
    JUNGBAUER, A
    KATINGER, H
    FAUPEL, M
    RIGHETTI, PG
    JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01): : 133 - 146
  • [3] PREPARATIVE PURIFICATION OF HUMAN MONOCLONAL-ANTIBODY ISOFORMS IN A MULTICOMPARTMENT ELECTROLYZER WITH IMMOBILINE MEMBRANES
    RIGHETTI, PG
    WENISCH, E
    JUNGBAUER, A
    KATINGER, H
    FAUPEL, M
    JOURNAL OF CHROMATOGRAPHY, 1990, 500 : 681 - 696
  • [4] PURIFICATION OF RECOMBINANT HUMAN GROWTH-HORMONE BY ISOELECTRIC-FOCUSING IN A MULTICOMPARTMENT ELECTROLYZER WITH IMMOBILINE MEMBRANES
    ETTORI, C
    RIGHETTI, PG
    CHIESA, C
    FRIGERIO, F
    GALLI, G
    GRANDI, G
    JOURNAL OF BIOTECHNOLOGY, 1992, 25 (03) : 307 - 318
  • [5] Purification of glycopeptide antibiotics by isoelectric focusing in multicompartment electrolyzers with Immobiline membranes
    Bossi, A
    Righetti, PG
    Riva, E
    Zerilli, L
    ELECTROPHORESIS, 1996, 17 (07) : 1234 - 1241
  • [6] PREPARATIVE SEPARATION OF PYROGENS FROM PROTEINS BY ISOELECTRIC-FOCUSING USING A MULTICOMPARTMENT ELECTROLYZER WITH IMMOBILINE MEMBRANES
    LUCAS, J
    FAUPEL, M
    GOECKING, C
    ELECTROPHORESIS, 1990, 11 (11) : 981 - 982
  • [7] PROTEIN SEPARATION BY PREPARATIVE MULTICOMPARTMENT ELECTROLYZER SECLUDED BY ISOELECTRIC MEMBRANES
    GOTO, M
    NITTA, T
    HIROSE, T
    SEPARATION SCIENCE AND TECHNOLOGY, 1993, 28 (11-12) : 1947 - 1958
  • [8] ISOELECTRIC-FOCUSING IN A MULTICOMPARTMENT ELECTROLYZER WITH ZWITTERIONIC MEMBRANES, EXEMPLIFIED BY PURIFICATION OF GLUCOAMYLASE
    WENISCH, E
    SCHNEIDER, P
    HANSEN, SA
    REZZONICO, R
    RIGHETTI, PG
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1993, 27 (03): : 199 - 213
  • [9] Protein purification in multicompartment electrolyzers with isoelectric membranes
    Righetti, PG
    Bossi, A
    Wenisch, E
    Orsini, G
    JOURNAL OF CHROMATOGRAPHY B, 1997, 699 (1-2): : 105 - 115
  • [10] APPLICATION OF VESICLE CHROMATOGRAPHY IN PROTEIN-PURIFICATION
    KLEINE, R
    WOEHLECKE, H
    EHWALD, R
    ACTA BIOTECHNOLOGICA, 1992, 12 (03): : 243 - 253