DIGITIZATION OF ELECTROCARDIOGRAMS BY DESK-TOP OPTICAL SCANNER

被引:13
|
作者
WIDMAN, LE [1 ]
HINES, LS [1 ]
机构
[1] VET ADM MED CTR, CARDIOL SERV, ALBUQUERQUE, NM 87108 USA
关键词
DIGITAL SIGNAL PROCESSING; OPTICAL SCANNER; ELECTROCARDIOGRAM; ANALOG-TO-DIGITAL CONVERSION; MICROCOMPUTER; MEDICAL RECORDS;
D O I
10.1016/0022-0736(91)90015-E
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The fidelity of a semiautomated technique for converting paper electrocardiogram (ECG) tracings to digital form by optical scanning was examined. Sample tracings from one nonmechanical and three mechanical ECG writers (recorders) were used. The optically scanned signals were compared with the digitized version (402 Hz, 12-bit precision) of the original analog signals using time- and frequency-domain correlation coefficients and root mean square error. A total of 261 QRS complexes and 207 RR intervals were examined in 21 leads acquired from 8 patients. When data were low-pass filtered at 25 Hz, the correlation coefficients for the 261 QRS complexes were 0.997 +/- 0.005 (mean +/- SD) for the time domain data, 0.992 +/- 0.010 for the complex frequency domain (amplitude and phase) data, and 0.998 +/- 0.002 for the power spectrum. The corresponding correlations for the 207 RR intervals were 0.993 +/- 0.008, 0.992 +/- 0.008, and 0.993 +/- 0.009. The RMS errors, normalized for signal amplitude, were 2.62 +/- 1.28 (percent +/- SD) for QRS complexes and 1.82 +/- 0.87 for RR intervals. The correlations for the mechanical ECG recorder tracings were the same or better than those of the nonmechanical recorder, and the RMS errors were generally smaller. When data were low-pass filtered at 105 Hz, the correlation coefficients ranged from 0.984 to 0.996 for the QRS complexes and 0.982 to 0.988 for RR intervals. Root mean square errors were 4.54 +/- 2.03 and 2.38 +/- 1.14, respectively. For purposes of arrhythmia analysis by QRS classification, digitization of ECG signals by optical scanning appears equivalent to acquisition via standard analog-to-digital conversion.
引用
收藏
页码:325 / 338
页数:14
相关论文
共 50 条
  • [1] DESK-TOP PUBLISHING
    WINKLER, C
    DATAMATION, 1986, 32 (23): : 92 - &
  • [2] INTEGRATING CORE DESIGN AND MONITORING ON THE DESK-TOP
    WILLIAMS, RD
    NUCLEAR ENGINEERING INTERNATIONAL, 1988, 33 (413): : 34 - &
  • [3] Automatic digitization of paper electrocardiograms-A systematic review
    Lence, Alex
    Extramiana, Fabrice
    Fall, Ahmad
    Salem, Joe-Elie
    Zucker, Jean-Daniel
    Prifti, Edi
    JOURNAL OF ELECTROCARDIOLOGY, 2023, 80 : 125 - 132
  • [4] Micromachined optical waveguide cantilever as a resonant optical scanner
    Wang, WC
    Fauver, M
    Ho, JN
    Seibel, EJ
    Reinhall, PG
    SENSORS AND ACTUATORS A-PHYSICAL, 2002, 102 (1-2) : 165 - 175
  • [5] Combining Optical Character Recognition With Paper ECG Digitization
    Ganesh, Shambavi
    Bhatti, Pamela T.
    Alkhalaf, Mhmtjamil
    Gupta, Shishir
    Shah, Amit J.
    Tridandapani, Srini
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2021, 9
  • [6] Development of a Calibration Device for the Optical Scanner
    Chen, Long
    Xiong, Yi-Kun
    Zhou, Sen
    Ni, Ying-Qian
    Xiong, Jun
    TENTH INTERNATIONAL CONFERENCE ON GRAPHICS AND IMAGE PROCESSING (ICGIP 2018), 2019, 11069
  • [7] Competing Gravitational and Viscous Effects in 3D Two-Phase Flow Investigated With a Table-Top Optical Scanner
    Brodin, Joachim Falck
    Rikvold, Per Arne
    Moura, Marcel
    Toussaint, Renaud
    Maloy, Knut Jorgen
    FRONTIERS IN PHYSICS, 2022, 10
  • [8] Development off an optical waveguide cantilever scanner
    Wang, WC
    Fauver, M
    Ho, JN
    Seibel, EJ
    Reinhall, PG
    OPTO-IRELAND 2002: OPTICS AND PHOTONICS TECHNOLOGIES AND APPLICATIONS, PTS 1 AND 2, 2003, 4876 : 72 - 83
  • [9] Comparison of Optical Scanner and Computed Tomography Scan Accuracy
    Kritikos, Michaela
    Urminsky, Jan
    Buransky, Ivan
    DIGITIZING PRODUCTION SYSTEMS, ISPR2021, 2022, : 521 - 530
  • [10] High-frequency optical scanner based on bending vibration of optical fiber
    Isago, R
    Domae, S
    Koyama, D
    Nakamura, K
    Ueha, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (5B): : 4773 - 4779