MINIMIZATION OF TARGET POSITIONING ERROR IN ACCELERATOR-BASED RADIOSURGERY

被引:27
作者
LOW, DA [1 ]
LI, ZF [1 ]
DRZYMALA, RE [1 ]
机构
[1] MALLINCKRODT INST RADIOL,ST LOUIS,MO
关键词
STEREOTAXIC RADIOSURGERY; QUALITY ASSURANCE;
D O I
10.1118/1.597475
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The stereotactic radiosurgery system used at the Mallinckrodt Institute of Radiology is patterned after that developed at the Joint Center for Radiation Therapy (Brigham & Women’s Hospital, Boston, MA) and uses the Brown-Roberts-Wells computed tomography (CT) stereotactic system. The patient’s head is attached to a stand that rotates with the treatment couch. The irradiation is conducted using a set of converging arcs of irradiation. Because of mechanical limitations, no accelerator or treatment couch is capable of placing the center of the radiation beam at precisely the same point for all gantry and couch angles and a compromise must be made when locating the nominal isocenter. The stand settings are checked by placing a radiopaque QA sphere at the desired target location. The QA sphere is imaged using a series of eight films exposed at a set of couch and gantry angles that encompass the treatment angles. The distances between the QA sphere image and the center of the radiation field indicate if the correct coordinates were set on the stand and if the radiation beam converges to a sufficiently small region (0.1-cm diameter) for treatment. A mathematical procedure has been developed to use the film-measured position errors to determine a stand offset that will minimize the distance between the accelerator isocenter and the target. The technique is capable of reducing the average placement error, as measured by imaging the QA sphere, to 0.035 cm with a maximum deviation of 0.07 cm. © 1995, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:443 / 448
页数:6
相关论文
共 11 条
[1]  
Brogan W. L., 1974, MODERN CONTROL THEOR
[2]   FINE-TUNING OF LINEAR-ACCELERATOR ACCESSORIES FOR STEREOTAXIC RADIOTHERAPY [J].
ENGLER, MJ ;
CURRAN, BH ;
TSAI, JS ;
STERNICK, ES ;
SELLES, WD ;
WAZER, DE ;
MASON, WP ;
SAILOR, T ;
MACKIE, TR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (04) :1001-1008
[3]   PRECISION AND ACCURACY OF STEREOTAXIC CONVERGENT-BEAM IRRADIATIONS FROM A LINEAR-ACCELERATOR [J].
HARTMANN, GH ;
BAUERKIRPES, B ;
SERAGO, CF ;
LORENZ, WJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (02) :481-492
[4]  
HEILBRUN MP, 1983, INSTRUCTION MANUAL B
[5]  
LARSON DA, 1993, INT J RADIAT ONCOL, V28, P523
[6]   A SYSTEM FOR STEREOTACTIC RADIOSURGERY WITH A LINEAR-ACCELERATOR [J].
LUTZ, W ;
WINSTON, KR ;
MALEKI, N .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (02) :373-381
[7]   STEREOTAXIC TARGET POINT VERIFICATION OF AN X-RAY AND CT LOCALIZER [J].
SERAGO, CF ;
LEWIN, AA ;
HOUDEK, PV ;
GONZALEZARIAS, S ;
HARTMANN, GH ;
ABITBOL, AA ;
SCHWADE, JG .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (03) :517-523
[8]   RADIOSURGERY TARGET POINT ALIGNMENT ERRORS DETECTED WITH PORTAL FILM VERIFICATION [J].
SERAGO, CF ;
LEWIN, AA ;
HOUDEK, PV ;
GONZALEZARIAS, S ;
SCHWADE, JG ;
ABITOL, A ;
MARCIALVEGA, V .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 24 (04) :777-780
[9]   QUALITY ASSURANCE IN STEREOTAXIC RADIOSURGERY USING A STANDARD LINEAR-ACCELERATOR [J].
TSAI, JS ;
BUCK, BA ;
SVENSSON, GK ;
ALEXANDER, E ;
CHENG, CW ;
MANNARINO, EG ;
LOEFFLER, JS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (03) :737-748
[10]   LINEAR-ACCELERATOR AS A NEUROSURGICAL TOOL FOR STEREOTACTIC RADIOSURGERY [J].
WINSTON, KR ;
LUTZ, W .
NEUROSURGERY, 1988, 22 (03) :454-464