TRANSCRANIAL DOPPLER FOR DETECTION OF CEREBRAL-ISCHEMIA DURING CAROTID ENDARTERECTOMY

被引:48
作者
JORGENSEN, LG
SCHROEDER, TV
机构
[1] Department of Vascular Surgery, Rigshospitalet, University of Copenhagen, Copenhagen
来源
EUROPEAN JOURNAL OF VASCULAR SURGERY | 1992年 / 6卷 / 02期
关键词
CEREBRAL BLOOD FLOW; CAROTID STENOSIS; ELECTROENCEPHALOGRAPHY; MIDDLE CEREBRAL ARTERY MEAN VELOCITY; ARTERIAL PRESSURE; PULSATILITY INDEX;
D O I
10.1016/S0950-821X(05)80231-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated transcranial Doppler sonography (TCD) for the detection of cerebral ischaemia during carotid endarterectomy in 30 male and 14 female patients with ipsilateral focal cerebro-vascular symptoms. Surgery was performed during halothane-nitrous oxide anaesthesia with moderate hypocapnia. Eight patients had a temporary shunt owing to contralateral occlusion or a stump pressure below 40 mmHg, and/or EEG flattening. Transcranial Doppler sonography was followed intra-operatively together with electro-encephalography (EEG), internal carotid artery (ICA) pressures and cerebral blood flow (CBF). Middle cerebral artery mean flow velocity (V(mean)) was 38 (22-96) cm s-1 (median and range) and decreased during cross-clamping to 28 (10-60) cm s-1 (p < 0.0001). After removal of the clamp it increased to 42 (20-102) cm s-1 (p < 0.0001). A V(mean) clamp of less than 30 cm s-1 together with a V(mean) clamp:V(mean) pre-clamp ratio of less than 0.6 showed an accuracy with respect to CBF below 20 ml 100 g-1 min-1 of 89%. A V(mean) clamp:V(mean) pre-clamp ratio below 0.4 detected all patients with EEG flattening (n = 3) (accuracy 97%). The corresponding level of accuracy obtained with stump pressure was 80%. The results indicate that middle cerebral flow velocity enables an increase in the accuracy of detecting cerebral ischaemia during carotid endarterectomy.
引用
收藏
页码:142 / 147
页数:6
相关论文
共 33 条
  • [1] Baker, Littooy, Hayes, Dorner, Stubbs, Carotid endarterectomy without a shunt: The control series, Journal of Vascular Surgery, 1, pp. 50-56, (1984)
  • [2] Ferguson, Intra-operative monitoring and internal shunts: are they necessary in carotid endarterectomy?, Stroke, 13, pp. 287-289, (1982)
  • [3] Sundt, Sharbrough, Anderson, Michenfelder, Cerebral blood flow measurements and electroencephalograms during carotid endarterectomy, J Neurosurg, 41, pp. 310-320, (1974)
  • [4] Sundt, The ischemic tolerance of neural tissue and the need for monitoring and selective shunting during carotid endarterectomy, Stroke, 14, (1983)
  • [5] Moore, Hall, Carotid artery back pressure. A test of cerebral tolerance to temporary carotid occlusion, Arch Surg, 99, pp. 702-710, (1969)
  • [6] Moore, Yee, Hall, Collateral cerebral blood pressure. An index of tolerance to temporary carotid occlusion, Arch Surg, 106, pp. 520-523, (1973)
  • [7] Boysen, Cerebral hemodynamics in carotid surgery, Acta Neurol Scand, 52, (1973)
  • [8] Boysen, Cerebral hemodynamics in carotid surgery, Acta Neurol Scand, 49, pp. 1-84, (1973)
  • [9] Ferguson, Gawache, Cerebral protection during carotid endarterectomy, anesthetic technique, and temporary shunts, Stroke and the Extracranial Vessels, pp. 187-201, (1984)
  • [10] Hafner, Evans, Carotid endarterectomy with local anesthesia: results and advantages, J Vase Surg, 7, pp. 232-239, (1988)