THE AGREEMENT BETWEEN PULMONARY AND SYSTEMIC BLOOD-FLOW MEASUREMENTS IN BABIES BY DUAL BEAM DOPPLER ECHOCARDIOGRAPHY

被引:2
|
作者
KAPUSTA, L
HOPMAN, JCW
DANIELS, O
机构
[1] Department of Paediatric Cardiology, St. Radboud University Hospital, Nijmegen
关键词
CARDIAC OUTPUT; DOPPLER ULTRASOUND; BABIES;
D O I
10.1093/oxfordjournals.eurheartj.a059856
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Measurement of cardiac output within the great arteries of infants by non-invasive Doppler echocardiographic techniques is limited. This paper describes a simple method, based on dual beam Doppler, that is capable of measuring the pulmonary and systemic blood flows independently of the vessel diameter and beam-blood flow angle. In 27 babies (12 of them were premature born) without intracardial shunts the accuracy of this method in measuring cardiac output was evaluated. The mean difference between pulmonary and systemic blood flow measurements was 0.02 (SD 0.06) l min-1.This study demonstrates a good agreement between the pulmonary and systemic blood flow measurements using dual beam Doppler ultrasound in babies. © 1991 The European Society of Cardiology.
引用
收藏
页码:112 / 116
页数:5
相关论文
共 50 条
  • [1] LIMITS OF REPRODUCIBILITY OF BLOOD-FLOW MEASUREMENTS BY DOPPLER ECHOCARDIOGRAPHY
    MEIJBOOM, EJ
    RIJSTERBORGH, H
    BOT, H
    DEBOO, JAJ
    ROELANDT, JRTC
    BOM, N
    AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (01): : 133 - 137
  • [2] LIMITS OF REPRODUCIBILITY OF BLOOD-FLOW MEASUREMENTS BY DOPPLER ECHOCARDIOGRAPHY
    MEIJBOOM, EJ
    RIJSTERBORGH, H
    BOT, H
    DEBOO, JAJ
    ROELANDT, JRTC
    BOM, N
    PEDIATRIC CARDIOLOGY, 1987, 8 (03) : 224 - 224
  • [3] MEASUREMENT OF SYSTEMIC AND PULMONARY BLOOD-FLOW AND QP-QS RATIO USING ECHOCARDIOGRAPHY AND DOPPLER VELOCIMETRY
    SANDERS, SP
    YEAGER, S
    WILLIAMS, RG
    CIRCULATION, 1982, 66 (04) : 231 - 231
  • [4] MEASUREMENT OF SYSTEMIC AND PULMONARY BLOOD-FLOW AND QP/QS RATIO USING DOPPLER AND TWO-DIMENSIONAL ECHOCARDIOGRAPHY
    SANDERS, SP
    YEAGER, S
    WILLIAMS, RG
    AMERICAN JOURNAL OF CARDIOLOGY, 1983, 51 (06): : 952 - 956
  • [5] DIASTOLIC FORWARD BLOOD-FLOW IN THE PULMONARY-ARTERY DETECTED BY DOPPLER ECHOCARDIOGRAPHY
    GIBBS, JL
    WILSON, N
    WITSENBURG, M
    WILLIAMS, GJ
    GOLDBERG, SJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (06) : 1322 - 1328
  • [6] MEASUREMENT OF PULMONARY BLOOD-FLOW WITH TRANSESOPHAGEAL 2-DIMENSIONAL AND DOPPLER ECHOCARDIOGRAPHY
    SAVINO, JS
    TROIANOS, CA
    AUKBURG, S
    WEISS, R
    REICHEK, N
    ANESTHESIOLOGY, 1991, 75 (03) : 445 - 451
  • [7] COMPARISON OF MULTIPLE VIEWS FOR THE EVALUATION OF PULMONARY ARTERIAL BLOOD-FLOW BY DOPPLER ECHOCARDIOGRAPHY
    LIGHTY, GW
    GARGIULO, A
    KRONZON, I
    POLITZER, F
    CIRCULATION, 1986, 74 (05) : 1002 - 1006
  • [8] EFFECT OF SAMPLING SITE ON ASSESSMENT OF PULMONARY-ARTERY BLOOD-FLOW BY DOPPLER ECHOCARDIOGRAPHY
    PANIDIS, IP
    ROSS, J
    MINTZ, GS
    AMERICAN JOURNAL OF CARDIOLOGY, 1986, 58 (11): : 1145 - 1147
  • [9] LASER DOPPLER MEASUREMENTS OF COCHLEAR BLOOD-FLOW
    MILLER, JM
    MARKS, NJ
    GOODWIN, PC
    HEARING RESEARCH, 1983, 11 (03) : 385 - 394
  • [10] DOPPLER MEASUREMENTS OF MATERNAL AND FETAL BLOOD-FLOW
    WATSON, PT
    YOUNG, WP
    HEGGE, FN
    CLINICAL OBSTETRICS AND GYNECOLOGY, 1987, 30 (04): : 948 - 955