EFFECTS OF INTRAOCULAR-LENS POSITION ERRORS ON POSTOPERATIVE REFRACTIVE ERROR

被引:80
作者
ERICKSON, P
机构
关键词
intraocular lens optics; intraocular lens power; postoperative astigmatism; postoperative refractive error;
D O I
10.1016/S0886-3350(13)80699-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Previous theoretical attempts to predict the refractive effects of intraocular lens (IOL) misalignment have resulted in conflicting information. Discrepancies in both the potential magnitude and direction of the refractive changes exist in the literature. This paper provides a detailed description of the mathematical framework required to achieve a valid predictive model and a quantitative analysis of the effects of IOL positional errors. The effects of misalignment are shown to influence the spherical refractive component primarily. Astigmatism related to oblique incidence is generally small. Movement of the IOL away from the retina produces myopia, while movement toward the retina produces hyperopia. It is likely that longitudinal IOL positional errors are a principal component of postoperative refractive errors. Alignment errors, on the other hand, must have generally minor effects on refraction. © 1990, American Society of Cataract and Refractive Surgery. All rights reserved.
引用
收藏
页码:305 / 311
页数:7
相关论文
共 28 条
[1]  
Gullstrand A, Photographic-ophthalmometric and clinical investigations of corneal refraction, translated by WM Ludlam, Optometry and Vision Science, 43, pp. 143-214, (1966)
[2]  
Tscherning M, Étude sur la position du cristallin de l'oeil humain, Mémoires D'Ophtalmométrie
[3]  
Annotés Et Précédés D'une Introduction, pp. 389-391, (1890)
[4]  
Moore JG, Intraocular implants: the postoperative astigmatism, Br J Ophthalmol, 64, pp. 318-321, (1980)
[5]  
Jolson AS, Seidl FJ, Postoperative astigmatism induced by intraocular lens tilt, Am Intra-Ocular Implant Soc J, 10, pp. 213-214, (1984)
[6]  
Lakshminarayanan V, Enoch JM, Raasch T, Et al., Refractive changes induced by intraocular lens tilt and longitudinal displacement, Arch Ophthalmol, 104, pp. 90-92, (1986)
[7]  
Brems RN, Apple DJ, Pfeffer BR, Et al., Posterior chamber intraocular lenses in a series of 75 autopsy eyes. Part III: Correlation of positioning holes and optic edges with the pupillary aperture and visual axis, J Cataract Refract Surg, 12, pp. 367-371, (1986)
[8]  
McDonnell PJ, Champion R, Green WR, Location and composition of haptics of posterior chamber intraocular lenses: histopathologic study of postmortem eyes, Ophthalmology, 94, pp. 136-142, (1987)
[9]  
Hansen SO, Tetz MR, Solomon KD, Et al., Decentration of flexible loop posterior chamber intraocular lenses in a series of 222 postmortem eyes, Ophthalmology, 95, pp. 344-349, (1988)
[10]  
Jagger WS, Jacobi KW, An analysis of pseudophakodonesis and iridodonesis, Am Intra-Ocular Implant Soc J, 5, pp. 203-206, (1979)