LIQUID-CHROMATOGRAPHIC ANALYSIS OF DOXAZOSIN IN HUMAN-SERUM WITH MANUAL AND ROBOTIC SAMPLE PREPARATION

被引:31
作者
FOUDA, HG
TWOMEY, TM
SCHNEIDER, RP
机构
关键词
D O I
10.1093/chromsci/26.11.570
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A specific method for the determination of the antihypertensive drug doxazosin in human serum is described. The method utilizes the related drug prazosin as an internal standard and is based on a simple extraction scheme followed by analysis by reversed-phase ion suppression high-performance liquid chromatography (HPLC) on an alumina-based column with fluorescence detection. The method is completely automated with a flexible robotic system for the analysis of drugs in biological fluids. The robotic automation of the method allows a 20% increase in the sample throughout and the savings of about 7 man-hours a day. Both the manual and robotic procedures yield precise quantitative results over the therapeutically relevant concentration range of 0.5 to 20 ng/mL of serum.
引用
收藏
页码:570 / 573
页数:4
相关论文
共 14 条
[1]   UNIVERSAL LIQUID-CHROMATOGRAPHIC METHODS .3. SENSITIVE, LOW-WAVELENGTH GRADIENTS WITH A NOVEL INJECTION-LOADING ION-PAIRING TECHNIQUE [J].
BERRY, VV ;
SHANSKY, RE .
JOURNAL OF CHROMATOGRAPHY, 1984, 284 (02) :303-318
[2]   DOXAZOSIN DETERMINATION BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING FLUORESCENCE DETECTION [J].
COWLISHAW, MG ;
SHARMAN, JR .
JOURNAL OF CHROMATOGRAPHY, 1985, 344 (NOV) :403-407
[3]   THE ANTIHYPERTENSIVE EFFECTS OF DOXAZOSIN - A CLINICAL OVERVIEW [J].
COX, DA ;
LEADER, JP ;
MILSON, JA ;
SINGLETON, W .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1986, 21 :S83-S90
[4]   QUANTITATIVE-ANALYSIS OF DOXYCYCLINE AND RELATED SUBSTANCES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DIHUIDI, K ;
KUCHARSKI, MJ ;
ROETS, E ;
HOOGMARTENS, J ;
VANDERHAEGHE, H .
JOURNAL OF CHROMATOGRAPHY, 1985, 325 (02) :413-424
[5]   A PHARMACODYNAMIC AND PHARMACOKINETIC ASSESSMENT OF A NEW ALPHA-ADRENOCEPTOR ANTAGONIST, DOXAZOSIN (UK33274) IN NORMOTENSIVE SUBJECTS [J].
ELLIOTT, HL ;
MEREDITH, PA ;
SUMNER, DJ ;
MCLEAN, K ;
REID, JL .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1982, 13 (05) :699-703
[6]   ROBOTICS FOR THE BIOANALYTICAL LABORATORY - A FLEXIBLE SYSTEM FOR THE ANALYSIS OF DRUGS IN BIOLOGICAL-FLUIDS [J].
FOUDA, HG ;
SCHNEIDER, RP .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1987, 6 (06) :139-147
[7]   THE METABOLISM AND KINETICS OF DOXAZOSIN IN MAN, MOUSE, RAT AND DOG [J].
KAYE, B ;
CUSSANS, NJ ;
FAULKNER, JK ;
STOPHER, DA ;
REID, JL .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1986, 21 :S19-S25
[8]   REVERSED-PHASE HPLC FROM PH-1 TO PH-13 [J].
LEE, DP .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1982, 20 (05) :203-208
[9]  
MAJORS RE, 1986, LC GC, V4, P304
[10]   DETERMINATION OF THE VASODILATOR UK33274 BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING FLUORESCENCE DETECTION [J].
RUBIN, PC ;
BRUNTON, J ;
MEREDITH, P .
JOURNAL OF CHROMATOGRAPHY, 1980, 221 (01) :193-195