Influencing factors of pneumothorax and parenchymal haemorrhage after CT-guided transthoracic needle biopsy: single-institution experience

被引:12
作者
Wattanasatesiri, Tunyarat [1 ]
Puntu, Warunyoo [1 ]
Vithitsuvanakul, Nophadol [1 ]
机构
[1] Thammasat Univ Hosp, Fac Med, Dept Radiol, Pathum Thani, Thailand
关键词
pneumothorax; computed tomography; accuracy; thoracic biopsy; pulmonary haemorrhage;
D O I
10.5114/pjr.2018.79202
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the incidences and influencing factors of pneumothorax and parenchymal haemorrhage after computed tomography (CT)-guided transthoracic needle biopsy (TTNB). Material and methods: A retrospective analysis of 216 patients who underwent CT-guided TTNB was performed. The frequencies and risk factors of pneumothorax and parenchymal haemorrhage were determined. P values less than 0.05 were considered statistically significant. Results: The incidences of pneumothorax and parenchymal haemorrhage were 23.1% and 45.4%, respectively. Twenty-two per cent of patients with pneumothorax needed percutaneous drainage, but all patients with parenchymal haemorrhage had clinical improvement after conservative treatment. No procedure-related mortality was detected. Univariate analysis showed that underlying pulmonary infection, lesion size of less than 1 cm, and lesion depth of more than 2 cm were significant influencing factors of pneumothorax. A significant relationship between the underlying chronic obstructive pulmonary disease (COPD) and the need for drainage catheter insertion was found. Pulmonary haemorrhage was more likely to occur in patients with underlying malignancy, solid pulmonary nodule, lesion size of 3 cm or less, and lesion depth of more than 3 cm. Consolidation was the protective factor for pulmonary haemorrhage. Sensitivity, specificity, positive predictive values (PPV) and negative predictive values (NPV), and accuracy of CT-guided core needle biopsy (CNB) for the diagnosis of malignancy were 95.7%, 100%, 100%, 93.3%, and 97.3%, respectively. The rate of diagnostic failure was 10.2%. Conclusions: Pulmonary hemorrhage is the most common complication after CT-guided TTNB. Influencing factors for pneumothorax are underlying pulmonary infection, lesion size < 1 cm, and lesion depth > 2 cm. Underlying malignancy, solid pulmonary nodule, lesion size <= 3 cm, and lesion depth > 3 cm am associated with pulmonary haemorrhage.
引用
收藏
页码:E379 / E388
页数:10
相关论文
共 50 条
[41]   Air embolism in CT-guided transthoracic needle biopsy: emphasis on pulmonary vein injury [J].
Ahn, Yura ;
Lee, Sang Min ;
Kim, Hwa Jung ;
Choe, Jooae ;
Oh, Sang Young ;
Do, Kyung-Hyun ;
Seo, Joon Beom .
EUROPEAN RADIOLOGY, 2022, 32 (10) :6800-6811
[42]   Factors that contribute to false-negative results in CT-guided transthoracic lung core-needle biopsy [J].
Sun, Daqian ;
Yao, Tianxiao ;
Wang, Lixin ;
Ma, Shengmei ;
Gao, Min ;
Li, Jingshuo ;
Li, Chunhai ;
Xu, Lisheng .
JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 (01) :86-91
[43]   Diagnostic feasibility and safety of CT-guided core biopsy for lung nodules less than or equal to 8 mm: A single-institution experience [J].
Ying-Yueh Chang ;
Chun-Ku Chen ;
Yi-Chen Yeh ;
Mei-Han Wu .
European Radiology, 2018, 28 :796-806
[44]   Age as a risk factor in the occurrence of pneumothorax after transthoracic fine needle biopsy: Our experience [J].
Vatrella, Alessandro ;
Galderisi, Antonio ;
Nicoletta, Carmine ;
Maglio, Angelantonio ;
Cortese, Antonio ;
Di Crescenzo, Rosa Maria ;
Ieni, Antonio ;
Crisci, Antonello ;
Di Crescenzo, Vincenzo .
INTERNATIONAL JOURNAL OF SURGERY, 2014, 12 :S29-S32
[45]   CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track [J].
Christian Billich ;
Rainer Muche ;
Gerhard Brenner ;
Stefan A. Schmidt ;
Stefan Krüger ;
Hans-Jürgen Brambs ;
Sandra Pauls .
European Radiology, 2008, 18 :1146-1152
[46]   CT-guided lung biopsy:: incidence of pneumothorax after instillation of NaCl into the biopsy track [J].
Billich, Christian ;
Muche, Rainer ;
Brenner, Gerhard ;
Schmidt, Stefan A. ;
Krueger, Stefan ;
Brambs, Hans-Juergen ;
Pauls, Sandra .
EUROPEAN RADIOLOGY, 2008, 18 (06) :1146-1152
[47]   The risk of immediate pneumothorax after CT-guided lung needle biopsy: pleural tail sign as a novel factor [J].
Peng, Bo ;
Deng, Zhenglong ;
Wang, Yuxi ;
Xu, Shuhao ;
Luo, Dong ;
Du, Zedong ;
Liu, Le ;
Hu, Ying ;
Ren, Yi .
QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (02) :707-719
[48]   CT-Guided Transthoracic Core-Needle Biopsy of Pulmonary Nodules: Current Practices, Efficacy, and Safety Considerations [J].
Constantinescu, Amalia ;
Stoicescu, Emil Robert ;
Iacob, Roxana ;
Chira, Cosmin Alexandru ;
Cocolea, Daiana Marina ;
Nicola, Alin Ciprian ;
Mladin, Roxana ;
Oancea, Cristian ;
Manolescu, Diana .
JOURNAL OF CLINICAL MEDICINE, 2024, 13 (23)
[49]   CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing [J].
Tian, Panwen ;
Wang, Ye ;
Li, Lei ;
Zhou, Yongzhao ;
Luo, Wenxin ;
Li, Weimin .
JOURNAL OF THORACIC DISEASE, 2017, 9 (02) :333-343
[50]   Results and complications of CT-guided transthoracic fine-needle aspiration biopsy of pulmonary lesions [J].
de Lima, Cristiano Dias ;
Nunes, Rodolfo Acatauassu ;
Saito, Eduardo Haruo ;
Higa, Claudio ;
Fernando Cardona, Zanier Jose ;
dos Santos, Denise Barbosa .
JORNAL BRASILEIRO DE PNEUMOLOGIA, 2011, 37 (02) :209-216