MODULATION TRANSFER-FUNCTIONS OF EYES IMPLANTED WITH INTRAOCULAR LENSES

被引:53
作者
NAVARRO, R [1 ]
FERRO, M [1 ]
ARTAL, P [1 ]
MIRANDA, I [1 ]
机构
[1] HOSP DOCE OCTUBRE, DEPT OFTALMOL, E-28041 MADRID, SPAIN
来源
APPLIED OPTICS | 1993年 / 32卷 / 31期
关键词
D O I
10.1364/AO.32.006359
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An experimental study of the retinal image quality in aged subjects after their eyes have been implanted with intraocular lenses (IOL's) has been performed. The method is based on recording in vivo the aerial image of a point test, after a double pass through the ocular media, and subsequent computation of the eye's modulation transfer function. The optical performance of three different types of bifocal IOL is compared with that of conventional monofocal IOL's. The results show that eyes implanted with bifocals exhibit a mean reduction in the modulation transfer function (contrast in the retinal image) of a factor of 2, while keeping a resolution similar to that of monofocal IOL's (which explains why visual acuities are also similar in these two cases). The mean retinal image modulation in eyes implanted with monofocal IOL's is approximately 2.5 times lower than that obtained with young emmetropic subjects, but it seems to be similar to that corresponding to # of persons of the same age (approximately 60 years) normal eyes.
引用
收藏
页码:6359 / 6367
页数:9
相关论文
共 24 条
[1]   SIMULTANEOUS MEASUREMENT OF 2-POINT-SPREAD FUNCTIONS AT DIFFERENT LOCATIONS ACROSS THE HUMAN FOVEA [J].
ARTAL, P ;
NAVARRO, R .
APPLIED OPTICS, 1992, 31 (19) :3646-3656
[2]  
ARTAL P, 1993, J OPT SOC AM A, V10, P1657
[3]   OPTICAL DESIGN OF INTRAOCULAR LENSES .1. ON-AXIS PERFORMANCE [J].
ATCHISON, DA .
OPTOMETRY AND VISION SCIENCE, 1989, 66 (08) :492-506
[4]   OPTICAL AND RETINAL FACTORS AFFECTING VISUAL RESOLUTION [J].
CAMPBELL, FW ;
GREEN, DG .
JOURNAL OF PHYSIOLOGY-LONDON, 1965, 181 (03) :576-+
[5]  
DEVALOIS RL, 1988, SPATIAL VISION, P149
[6]  
GINSBURG P, 1987, ADV DIAGNOSTIC VISUA, P132
[8]   PSYCHOPHYSICS OF READING .1. NORMAL VISION [J].
LEGGE, GE ;
PELLI, DG ;
RUBIN, GS ;
SCHLESKE, MM .
VISION RESEARCH, 1985, 25 (02) :239-252
[9]  
MAXWELL A, 1991, MULTIFOCAL INTRAOCUL
[10]  
MIRANDA I, 1991, THESIS U COMPLUTENSE