Objective This study compared two forms of high-frequency ventilation (HFV) with conventional volume ventilation (CON) in a primate model of inhalation injury to determine whether ventilatory mode was a determinant of pulmonary damage. Summary Background Data The authors previously reported that the prophylactic use of high-frequency flow interruption in patients with bronchoscopically diagnosed inhalation injury requiring mechanical ventilatory support resulted in a significant decrement in mortality. They hypothesized that a reduction in ventilatory mode induced pulmonary damage was in part responsible for their clinical results. Methods Fifteen adult baboons were randomized to one of three ventilatory modes (CON, high-frequency flow interruption [HFFI], or high-frequency oscillatory ventilation [HFO]) after moderate smoke injury. Ventilatory support was tailored to the same physiologic endpoints. After 7 days, the animals were killed and pulmonary pathologic changes were scored and compared. Repetitive physiologic and biochemical data were compared using analysis of variance for repeated measures. Results Physiologic endpoints were achieved in CON and HFFI, but not in HFO. Hemodynamic variables did not diff er between CON and HFFI. The barotrauma index was greater in CON compared to HFFI (p < 0.05), despite similar PO2, FlO2, AA gradient, and PCO2. Animals treated with HFFI had significantly less parenchymal damage than those treated with CON (p = 0.03) or HFO (p = 0.0008). Conclusions The prophylactic use of HFFI led to a significant decrement in ventilatory mode induced pulmonary damage and offers an explanation for the decreased mortality in inhalation injury patients treated with HFFI.
引用
收藏
页码:328 / 337
页数:10
相关论文
共 23 条
[1]   HOW TO USE RIDIT ANALYSIS [J].
BROSS, IDJ .
BIOMETRICS, 1958, 14 (01) :18-38
[2]   HIGH-FREQUENCY PERCUSSIVE VENTILATION IN PATIENTS WITH INHALATION INJURY [J].
CIOFFI, WG ;
GRAVES, TA ;
MCMANUS, WF ;
PRUITT, BA .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1989, 29 (03) :350-354
[3]   PROPHYLACTIC USE OF HIGH-FREQUENCY PERCUSSIVE VENTILATION IN PATIENTS WITH INHALATION INJURY [J].
CIOFFI, WG ;
RUE, LW ;
GRAVES, TA ;
MCMANUS, WF ;
MASON, AD ;
PRUITT, BA .
ANNALS OF SURGERY, 1991, 213 (06) :575-582
[4]  
COLLINS D S, 1992, American Review of Respiratory Disease, V145, pA35
[5]   VENTILATORY MANAGEMENT OF INFANT BABOONS WITH HYALINE-MEMBRANE DISEASE - THE USE OF HIGH-FREQUENCY VENTILATION [J].
DELEMOS, RA ;
COALSON, JJ ;
GERSTMANN, DR ;
NULL, DM ;
ACKERMAN, NB ;
ESCOBEDO, MB ;
ROBOTHAM, JL ;
KUEHL, TJ .
PEDIATRIC RESEARCH, 1987, 21 (06) :594-602
[6]   HIGH INFLATION PRESSURE PULMONARY-EDEMA - RESPECTIVE EFFECTS OF HIGH AIRWAY PRESSURE, HIGH TIDAL VOLUME, AND POSITIVE END-EXPIRATORY PRESSURE [J].
DREYFUSS, D ;
SOLER, P ;
BASSET, G ;
SAUMON, G .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1988, 137 (05) :1159-1164
[7]   PRESSURE-VOLUME CURVE OF TOTAL RESPIRATORY SYSTEM IN ACUTE RESPIRATORY-FAILURE - COMPUTED TOMOGRAPHIC SCAN STUDY [J].
GATTINONI, L ;
PESENTI, A ;
AVALLI, L ;
ROSSI, F ;
BOMBINO, M .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1987, 136 (03) :730-736
[8]   COMPARISON OF CONVENTIONAL AND HIGH-FREQUENCY VENTILATION - OXYGENATION AND LUNG PATHOLOGY [J].
HAMILTON, PP ;
ONAYEMI, A ;
SMYTH, JA ;
GILLAN, JE ;
CUTZ, E ;
FROESE, AB ;
BRYAN, AC .
JOURNAL OF APPLIED PHYSIOLOGY, 1983, 55 (01) :131-138
[9]   CHEST WALL RESTRICTION LIMITS HIGH AIRWAY PRESSURE-INDUCED LUNG INJURY IN YOUNG-RABBITS [J].
HERNANDEZ, LA ;
PEEVY, KJ ;
MOISE, AA ;
PARKER, JC .
JOURNAL OF APPLIED PHYSIOLOGY, 1989, 66 (05) :2364-2368
[10]  
HIFI Study Group, 1989, N Engl J Med, V320, P88