HISTAMINE EFFECT ON HUMAN CUTANEOUS BLOOD-FLOW - REGIONAL VARIATIONS

被引:0
|
作者
TUR, E
AVIRAM, G
ZELTSER, D
BRENNER, S
MAIBACH, HI
机构
[1] TEL AVIV UNIV,ELIAS SOURASKY MED CTR,DEPT DERMATOL,IL-69978 TEL AVIV,ISRAEL
[2] UNIV CALIF SAN FRANCISCO,SCH MED,DEPT DERMATOL,SAN FRANCISCO,CA 94143
关键词
LASER DOPPLER FLOWMETRY;
D O I
暂无
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Different reactivities of small blood vessels to the histamine released by exogenous and endogenous substances may play a role in the regional variations of the elicited cutaneous response. To study the regional dependence of cutaneous blood flow in response to histamine, the compound was administered intradermally (prick introduction), thereby bypassing the spatially dependent penetration process.The induced response was quantified with cutaneous blood flow measurements utilizing laser Doppler flowmetry. Extent of response and time parameters were compared. Three anatomical sites, the back, volar side of the forearm, and ankle, were studied on 20 volunteers (10 men and 10 women, age 24-34). For comparison, topical administration was also performed. Significant differences in the measured responses at the three sites were observed: the increase of the cutaneous blood flow on the back was greater than the forearm (p < 0.01 prick test, p < 0.05 topical application), and that of both sites was greater than the ankle (p < 0.01 prick test, p < 0.05 topical application). There were no significant differences among the different sites in time parameters and no gender variations. As expected, the time required to reach maximum response was shorter for the intradermal method as compared to the topical application on the back (p < 0.001) and forearm (p < 0.05). On the other hand, the time required to decrease to 50% of maximum response was not different for the intradermal and topical methods of histamine application. These blood vessel response observations may provide initial insight into inherent functional differences influencing cutaneous manifestations of endogenous and exogenous diseases.
引用
收藏
页码:113 / 116
页数:4
相关论文
共 50 条
  • [31] MONITORING OF CORTICAL BLOOD-FLOW IN HUMAN EPILEPTIC FOCI USING LASER-DOPPLER FLOWMETRY
    RONNEENGSTROM, E
    CARLSON, H
    BLOM, S
    FLINK, R
    GAZELIUS, B
    SPANNARE, B
    HILLERED, L
    JOURNAL OF EPILEPSY, 1993, 6 (03): : 145 - 151
  • [32] DYNAMICS OF THE SKIN BLOOD-FLOW RESPONSE TO HISTAMINE - COMPARISON OF THE EFFECTS OF CETIRIZINE AND LORATADINE ON THE SKIN-RESPONSE TO A HISTAMINE DRY PRICK TEST MONITORED WITH LASER-DOPPLER FLOWMETRY
    VANNESTE, D
    RIHOUX, JP
    DERMATOLOGY, 1993, 186 (04) : 281 - 283
  • [33] A NEW METHOD FOR CONTINUOUS MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW USING LASER-DOPPLER FLOWMETRY IN A CONSCIOUS RAT
    SATO, A
    UCHIDA, S
    YAMAUCHI, Y
    NEUROSCIENCE LETTERS, 1994, 175 (1-2) : 149 - 152
  • [34] CHOROIDAL BLOOD-FLOW BY LASER-DOPPLER FLOWMETRY
    RIVA, CE
    PETRIG, BL
    OPTICAL ENGINEERING, 1995, 34 (03) : 746 - 752
  • [35] AUTOREGULATION OF COCHLEAR BLOOD-FLOW IN GUINEA-PIGS
    BROWN, JN
    NUTTALL, AL
    AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 266 (02): : H458 - H467
  • [36] DIRECT MEASUREMENT OF RENAL MEDULLARY BLOOD-FLOW IN THE DOG
    STRICK, DM
    FIKSENOLSEN, MJ
    LOCKHART, JC
    ROMAN, RJ
    ROMERO, JC
    AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 267 (01): : R253 - R259
  • [37] TENDON BLOOD-FLOW ASSESSED BY LASER DOPPLER FLOWMETRY
    ASTROM, M
    SVENSSON, H
    SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1991, 25 (03): : 213 - 215
  • [38] NITRIC-OXIDE AND CHOROIDAL BLOOD-FLOW REGULATION
    MANN, RM
    RIVA, CE
    STONE, RA
    BARNES, GE
    CRANSTOUN, SD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (05) : 925 - 930
  • [39] SELF-MIXING EFFECT OF THE SEMICONDUCTOR-LASER DOPPLER METHOD FOR BLOOD-FLOW MEASUREMENT
    MITO, K
    IKEDA, H
    SUMI, M
    SHINOHARA, S
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 (03) : 308 - 310
  • [40] DUODENAL MUCOSAL ALKALINE SECRETION, PERMEABILITY, AND BLOOD-FLOW
    NYLANDER, O
    HALLGREN, A
    HOLM, L
    AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 265 (06): : G1029 - G1038