EVOKED-POTENTIAL MONITORING DURING POSTERIOR-FOSSA ANEURYSM SURGERY - A COMPARISON OF 2 MODALITIES

被引:47
|
作者
MANNINEN, PH [1 ]
PATTERSON, S [1 ]
LAM, AM [1 ]
GELB, AW [1 ]
NANTAU, WE [1 ]
机构
[1] UNIV WESTERN ONTARIO HOSP, DEPT ANAESTHESIA, LONDON, ON, CANADA
来源
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE | 1994年 / 41卷 / 02期
关键词
ANESTHESIA; NEUROSURGICAL; MONITORING; EVOKED POTENTIALS; SOMATOSENSORY; BRAIN-STEM AUDITORY; SURGERY; NEUROLOGICAL;
D O I
10.1007/BF03009798
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The purpose of this study was to compare and assess the ability of two different evoked potential (EP) modalities, median nerve somatosensory evoked potentials (SSEP) and brainstem auditory evoked potentials (BAEP) in monitoring for cerebral ischaemia and in predicting neurological outcome during posterior fossa aneurysm surgery. During 70 procedures, patients were monitored with both SSEP and BAEP. Temporary occlusion of an artery was used in 52 patients and permanent occlusion in 21 patients. A change was defined as a greater than 50% decrease in amplitude and/or an increase in latency greater than 1 msec of the N20 (cortical waveform) for SSEP monitoring and of the fifth peak for BAEP monitoring. Neurological assessment of the patient was performed immediately on emergence, after 24 hr and at the time of discharge. In total, 14 patients had an SSEP change which predicted a neurological deficit in eight patients (57%). Ten patients had a change in BAEP; six had a neurological deficit (60%). Five patients had a change in both, two had a deficit (40%). The incidence of false negative results (a neurological deficit but no EP change) for both modalities was 20% (SSEP 47%, BAEP 60%). The incidence of false positive results (an EP change but no deficit) was 13% overall (SSEP 11%, BAEP 7%). All patients who had a permanent EP change developed a neurological deficit. We did not find a difference in the ability of SSEP compared with BAEP in predicting neurological deficits but, using both modalities, the incidence of false negative results was decreased. In conclusion, dual modality monitoring should be used whenever possible as neither modality alone war better than the other in detecting cerebral ischaemia and in predicting neurological deficits.
引用
收藏
页码:92 / 97
页数:6
相关论文
共 29 条
  • [21] Cautionary findings for motor evoked potential monitoring in intracranial aneurysm surgery after a single administration of rocuronium to facilitate tracheal intubation
    Hayashi, Hironobu
    Bebawy, John F.
    Koht, Antoun
    Hemmer, Laura B.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2021, 35 (04) : 903 - 911
  • [22] Impact of anesthesia on transcranial electric motor evoked potential monitoring during spine surgery: a review of the literature
    Wang, Anthony C.
    Than, Khoi D.
    Etame, Arnold B.
    La Marca, Frank
    Park, Paul
    NEUROSURGICAL FOCUS, 2009, 27 (04) : E7.1 - E7.4
  • [23] Motor evoked potential monitoring can evaluate ischemic tolerance to carotid artery occlusion during surgery
    Takamura, Yoshiaki
    Motoyama, Yasushi
    Takatani, Tsunenori
    Takeshima, Yasuhiro
    Matsuda, Ryosuke
    Tamura, Kentaro
    Yamada, Shuichi
    Nishimura, Fumihiko
    Nakagawa, Ichiro
    Park, Young-Su
    Nakase, Hiroyuki
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2021, 35 (05) : 1055 - 1062
  • [24] Effect of sevoflurane/nitrous oxide versus propofol anaesthesia on somatosensory evoked potential monitoring of the spinal cord during surgery to correct scoliosis
    Ku, ASW
    Hu, Y
    Irwin, MG
    Chow, B
    Gunawardene, S
    Tan, EE
    Luk, KDK
    BRITISH JOURNAL OF ANAESTHESIA, 2002, 88 (04) : 502 - 507
  • [25] Improvement of motor evoked potentials monitoring is required during thoracic or thoracoabdominal aortic aneurysm surgery under hypothermic cardiopulmonary bypass
    Kawaguchi, Masahiko
    Kawamata, Mikito
    Yamada, Yoshitsugu
    JOURNAL OF ANESTHESIA, 2012, 26 (02) : 157 - 159
  • [26] Motor evoked potential monitoring during spinal surgery: Responses of distal limb muscles to transcranial cortical stimulation with pulse trains
    Jones, SJ
    Harrison, R
    Koh, KF
    Mendoza, N
    Crockard, HA
    EVOKED POTENTIALS-ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1996, 100 (05): : 375 - 383
  • [27] Evaluation of Reliability of Post-Tetanic Motor-Evoked Potential Monitoring During Spinal Surgery Under General Anesthesia
    Hayashi, Hironobu
    Kawaguchi, Masahiko
    Yamamoto, Yuri
    Inoue, Satoki
    Koizumi, Munehisa
    Ueda, Yurito
    Takakura, Yoshinori
    Furuya, Hitoshi
    SPINE, 2008, 33 (26) : E994 - E1000
  • [28] Utility of bispectral vs auditory evoked potential monitoring during anesthetic maintenance in combined sevoflurane-regional anesthesia in pediatric patients: comparison with standard practice
    Alvarez, J. C.
    Santiveri, F. X.
    Rodriguez, B.
    Gonzalez, I.
    Gonzalez-Rivero, M. A.
    Escolano, F.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2008, 55 (09): : 527 - 534
  • [29] Motor evoked potential-guided segmental artery revascularization during open thoracoabdominal aortic aneurysm surgery after coil embolization as a part of the minimally invasive staged segmental artery coil embolization concept
    Doukas, Panagiotis
    Gombert, Alexander
    Kotelis, Drosos
    Jacobs, Michael J.
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2022, 8 (02): : 206 - 209