APPLICATION OF A MULTICHANNEL POTENTIOSTAT TO METAL-ION DETERMINATIONS IN FLOW-INJECTION ANALYSIS

被引:0
|
作者
MCGRATH, MJ [1 ]
FANG, T [1 ]
DIAMOND, D [1 ]
SMYTH, MR [1 ]
机构
[1] DUBLIN CITY UNIV,SCH CHEM SCI,DUBLIN 9,IRELAND
关键词
MULTICHANNEL POTENTIOSTAT; AMPEROMETRIC ARRAY; FLOW INJECTION ANALYSIS; METAL IONS; 3-D VOLTAMMOGRAMS;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A 4-channel potentiostat has been developed for use with an amperometric array and applied to the determination of a mixture of metal ions in flow injection analysis (FIA). The use of an array facilitates the acquisition of three dimensional electrochemical information in real-time (current vs. potential vs. time). The data acquired can be saved in ASCII format which facilitates post-run plotting of the 2- and 3-D voltammograms in Microsoft Excel. The results demonstrate the increased information content available with an amperometric array over fixed potential electrodes. The ability to identify the individual species in mixed component injections, which is normally not possible with FIA without a prior separation step has been demonstrated. Linear responses to injections of copper(II) ions in the concentration range 500 ppm to 100 ppb were obtained.
引用
收藏
页码:685 / 696
页数:12
相关论文
共 50 条
  • [41] LIQUID-LIQUID-EXTRACTION FLOW-INJECTION ANALYSIS
    KUBAN, V
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1991, 22 (06) : 477 - 557
  • [42] AMPEROMETRIC DETERMINATION OF BILIRUBIN WITH FLOW-INJECTION ANALYSIS SYSTEM
    BAE, ZU
    LEE, HL
    PARK, TM
    SEO, ML
    ANALYTICAL LETTERS, 1995, 28 (10) : 1775 - 1783
  • [43] FLOW-INJECTION ANALYSIS WITH ONLINE PRECONCENTRATION OF TRACE SELENIUM
    AOYAMA, E
    AKAMATSU, K
    NAKAGAWA, T
    TANAKA, H
    ANALYTICAL SCIENCES, 1991, 7 (04) : 617 - 621
  • [44] NOVEL FLOW-INJECTION APPROACHES TO ENVIRONMENTAL-ANALYSIS
    DECASTRO, MDL
    VALCARCEL, M
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1990, 38 (02) : 171 - 183
  • [45] Spectroelectrochemical determination of chlorpromazine hydrochloride by flow-injection analysis
    Daniel, D
    Gutz, IGR
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (02) : 281 - 286
  • [46] Fluorimetric determination of free cyanide by flow-injection analysis
    Beck, HP
    Zhang, B
    Bordeanu, A
    ANALYTICAL LETTERS, 2003, 36 (10) : 2211 - 2228
  • [47] Flow-injection amperometric detection with solvent polymeric membrane ion sensors
    Ortuño, JA
    Hernández, J
    Sánchez-Pedreño, CN
    ELECTROANALYSIS, 2004, 16 (10) : 827 - 831
  • [48] DETERMINATION OF AMMONIA IN SEAWATER BY MULTICHANNEL FLOW INJECTION ANALYSIS
    Han, Bin
    Zheng, Li
    Wang, Xiao-ru
    Wang, Jiang-tao
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2015, 43 (06) : 626 - 632
  • [49] Determination of lidocaine by flow-injection analysis with electrochemical detection
    Koitabashi, M
    Kotani, A
    Kusu, F
    BUNSEKI KAGAKU, 2003, 52 (12) : 1137 - 1140
  • [50] Chemical speciation by flow-injection analysis. A review
    Campanella, L
    Pyrzynska, K
    Trojanowicz, M
    TALANTA, 1996, 43 (06) : 825 - 838