APPLICATION OF A MULTICHANNEL POTENTIOSTAT TO METAL-ION DETERMINATIONS IN FLOW-INJECTION ANALYSIS

被引:0
|
作者
MCGRATH, MJ [1 ]
FANG, T [1 ]
DIAMOND, D [1 ]
SMYTH, MR [1 ]
机构
[1] DUBLIN CITY UNIV,SCH CHEM SCI,DUBLIN 9,IRELAND
关键词
MULTICHANNEL POTENTIOSTAT; AMPEROMETRIC ARRAY; FLOW INJECTION ANALYSIS; METAL IONS; 3-D VOLTAMMOGRAMS;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A 4-channel potentiostat has been developed for use with an amperometric array and applied to the determination of a mixture of metal ions in flow injection analysis (FIA). The use of an array facilitates the acquisition of three dimensional electrochemical information in real-time (current vs. potential vs. time). The data acquired can be saved in ASCII format which facilitates post-run plotting of the 2- and 3-D voltammograms in Microsoft Excel. The results demonstrate the increased information content available with an amperometric array over fixed potential electrodes. The ability to identify the individual species in mixed component injections, which is normally not possible with FIA without a prior separation step has been demonstrated. Linear responses to injections of copper(II) ions in the concentration range 500 ppm to 100 ppb were obtained.
引用
收藏
页码:685 / 696
页数:12
相关论文
共 50 条
  • [21] Flow-injection enzymatic analysis for glycerol and triacylglycerol
    Wu, LC
    Cheng, CM
    ANALYTICAL BIOCHEMISTRY, 2005, 346 (02) : 234 - 240
  • [22] AMMONIUM DETECTION USING AN ION-SELECTIVE ELECTRODE ARRAY IN FLOW-INJECTION ANALYSIS
    DEVITERI, FJS
    DIAMOND, D
    ELECTROANALYSIS, 1994, 6 (01) : 9 - 16
  • [23] Sensitive flow-injection spectrophotometric analysis of bromopride
    Lima, Liliane Spazzapam
    Weinert, Patricia Los
    Pezza, Leonardo
    Pezza, Helena Redigolo
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2014, 133 : 597 - 604
  • [24] APPLICATION OF FLOW-INJECTION ANALYSIS IN TRACE-ELEMENT DETERMINATION OF BODY-FLUIDS
    BURGUERA, JL
    BURGUERA, M
    JOURNAL OF TRACE ELEMENTS AND ELECTROLYTES IN HEALTH AND DISEASE, 1993, 7 (01): : 9 - 18
  • [25] Flow-injection analysis of norepinephrine bitartrate by ion association with anionic surfactant using a piezoelectric detector
    Mo, ZH
    Zhang, MJ
    Li, ML
    Xia, ZL
    ANALYTICAL LETTERS, 1997, 30 (04) : 663 - 671
  • [26] Application of artificial neural networks to predictions in flow-injection spectrophotometry
    V. N. Reshetnikova
    V. V. Kuznetsov
    S. S. Borodulin
    Journal of Analytical Chemistry, 2016, 71 : 243 - 247
  • [27] Application of artificial neural networks to predictions in flow-injection spectrophotometry
    Reshetnikova, V. N.
    Kuznetsov, V. V.
    Borodulin, S. S.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 71 (03) : 243 - 247
  • [28] Flow-injection analysis of pyridoxine hydrochloride by coupling with the diazonium ion of p-sulfanilic acid
    Monferrer-Pons, L
    Alvarez-Rodríguez, L
    Esteve-Romero, J
    García-Alvarez-Coque, MC
    ANALYTICAL LETTERS, 2000, 33 (03) : 539 - 552
  • [29] Chemiluminescence determination of thioridazine hydrochloride by flow-injection analysis
    Kojlo, A
    Michalowski, J
    Wolyniec, E
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 22 (01) : 85 - 91
  • [30] Determination of phenol in water by flow-injection chemiluminescence analysis
    Gong, ZJ
    Huang, YM
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (09) : 1123 - 1125