FOURIER CODED-APERTURE IMAGING IN NUCLEAR-MEDICINE

被引:0
|
作者
CHOU, C
机构
[1] Natl Yang Ming Medical Coll, Taipei
关键词
CODED APERTURE; GAMMA-RAY IMAGING; MOIRE; TOMOGRAPHY;
D O I
10.1049/ip-smt:19949767
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A Fourier aperture (FA) is composed of two sinusoidal gratings in contact. When the two gratings rotate on the same axis in equal angles but opposite directions a clear pattern of difference moire fringes is formed, the moire frequency depending on the angle between the two gratings. This aperture of moire fringes is used as a variable frequency grating which is able to scan the object spectrum in the frequency domain. The summation-filtered back projection algorithm with three different apodising functions was introduced in the reconstruction. A Tc-99m gamma ray source and a 1 in-diameter NaI scintillation detector were used in the experiment. The thyroid phantom images showed that spatial resolution of FA agrees with the theoretical prediction. Three dimensional image capability is also discussed. The matrix inversion algorithm was used in the computer simulation of 3-D images. Although the depth resolution of a FA is limited by the restricted view angle of the detector, two plane objects free from noise at different depths were reconstructed.
引用
收藏
页码:179 / 184
页数:6
相关论文
共 50 条
  • [31] Coded-Aperture Computational Millimeter-Wave Image Classifier Using Convolutional Neural Network
    Sharma, Rahul
    Hussung, Raphael
    Keil, Andreas
    Friederich, Fabian
    Fromenteze, Thomas
    Khalily, Mohsen
    Deka, Bhabesh
    Fusco, Vincent
    Yurduseven, Okan
    IEEE ACCESS, 2021, 9 : 119830 - 119844
  • [32] Scene-adaptive coded aperture imaging
    Wang, Xuehui
    Dai, Feng
    Ma, Yike
    Gao, Ke
    Zhang, Yong Dong
    MULTIMEDIA TOOLS AND APPLICATIONS, 2019, 78 (01) : 697 - 711
  • [33] Effect of keystone on coded aperture spectral imaging
    Qian, Lu-lu
    Lu, Qun-bo
    Huang, Min
    Cai, Qi-sheng
    Bin Xiang-li
    OPTIK, 2016, 127 (02): : 686 - 689
  • [34] Improvements in coded aperture thermal neutron imaging
    Vanier, PE
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS V, 2003, 5199 : 124 - 131
  • [35] Scene-adaptive coded aperture imaging
    Xuehui Wang
    Feng Dai
    Yike Ma
    Ke Gao
    Yong Dong Zhang
    Multimedia Tools and Applications, 2019, 78 : 697 - 711
  • [36] Analysis and Correction of Coded Pixel Distortion in Coded Aperture Imaging Spectrometer
    Zhu Dantong
    Shen Honghai
    Yang Mingyu
    Chen Cheng
    Nan Tongling
    LASER & OPTOELECTRONICS PROGRESS, 2018, 55 (06)
  • [37] A back-projection approach to coded aperture imaging for SPECT applications
    Costantino, A.
    Bird, A. J.
    Schuffham, J.
    Guy, M.
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [39] Coded-aperture based stereo gamma-ray imager for near field 3-D localization
    Lee, Seungho
    Song, Minseo
    Kim, Dukwoo
    Lee, Joonhyuk
    Ko, Changyu
    Jeong, Manhee
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (07)
  • [40] Super resolution simulation of terahertz coded aperture imaging
    Wang, Bowen
    Zou, Yan
    Zuo, Chao
    Li, Le
    TERAHERTZ, RF, MILLIMETER, AND SUBMILLIMETER-WAVE TECHNOLOGY AND APPLICATIONS XIV, 2021, 11685