A model of parametric X-ray radiation for application to diagnostic radiology

被引:0
|
作者
Di Domenico, G. [1 ,2 ]
Cardarelli, P. [1 ,2 ]
Comandini, A. [1 ]
Gambaccini, M. [1 ,2 ]
Marziani, M. [1 ,2 ]
Taibi, A. [1 ,2 ]
机构
[1] Univ Ferrara, Dipartimento Fis, Via Saragat 1, I-44121 Ferrara, Italy
[2] INFN, Sez Ferrara, I-44121 Ferrara, Italy
关键词
D O I
10.1393/ncc/i2011-10949-y
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Parametric X-ray Radiation (PXR) is well known as an intense, tunable and quasi-monochromatic X-ray source. From the very first work of TerMikaelian, who proposed the interaction phenomenon for Parametric X-rays many theoretical and experimental studies have investigated the characteristics of such a novel X-ray source. Within the framework of classical electrodynamics, we have thoroughly studied the physical implications of electrons moving through a medium at relativistic speed and then developed an analytical model of X-ray diffraction based on the PXR phenomenon. The model has been used to obtain information on the characteristics of PXR diffracted beam in terms of X-ray intensity, energy spectrum and angular distribution. Several crystals have been studied both in Bragg and Laue geometry and their relative yield has been compared. Preliminary results on the diagnostic potential of PXR have shown that, at a distance from the crystal which produces a size of the X-ray field useful for an imaging application, the photon yield of PXR is higher than that produced by a conventional X-ray tube, provided that a similar electron current is available.
引用
收藏
页码:207 / 212
页数:6
相关论文
共 50 条
  • [31] PROPHYLACTIC RADIATION PROTECTION IN X-RAY DIAGNOSTIC
    VOGEL, H
    LOHR, H
    MEDIZINISCHE WELT, 1982, 33 (04): : 127 - 129
  • [32] RADIATION DOSES IN DIAGNOSTIC X-RAY PROCEDURES
    LINCOLN, TA
    GUPTON, ED
    RADIOLOGY, 1958, 71 (02) : 208 - 215
  • [33] RADIATION EXPOSURE IN DIAGNOSTIC X-RAY DEPARTMENTS
    OLIVER, R
    BRITISH JOURNAL OF RADIOLOGY, 1969, 42 (500): : 633 - &
  • [34] Kinematic grouping of reflections of parametric X-ray radiation
    A. S. Gogolev
    A. P. Potylitsin
    S. R. Uglov
    Journal of Surface Investigation. X-ray, Synchrotron and Neutron Techniques, 2008, 2 : 217 - 224
  • [35] Observation of parametric X-ray radiation by an imaging plate
    Takabayashi, Y.
    Shchagin, A. V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2012, 278 : 78 - 81
  • [36] Fresnel coefficients for parametric X-ray (Cherenkov) radiation
    Shchagin, A. V.
    PHYSICS-USPEKHI, 2015, 58 (08) : 819 - 827
  • [37] Parametric X-ray radiation as a beam size monitor
    Takabayashi, Y.
    PHYSICS LETTERS A, 2012, 376 (35) : 2408 - 2412
  • [38] Current status of parametric X-ray radiation research
    Shchagin, AV
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 283 - 291
  • [39] Kinematic Grouping of Reflections of Parametric X-ray Radiation
    Gogolev, A. S.
    Potylitsin, A. P.
    Uglov, S. R.
    JOURNAL OF SURFACE INVESTIGATION, 2008, 2 (02): : 217 - 224
  • [40] Parametric X-ray radiation by relativistic channeled particles
    Ikeda, T
    Matsuda, Y
    Nitta, H
    Ohtsuki, YH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 115 (1-4): : 380 - 383