QUALITY-CONTROL OF INHOMOGENEITY CORRECTION ALGORITHMS USED IN TREATMENT PLANNING SYSTEMS

被引:16
|
作者
KAPPAS, C [1 ]
ROSENWALD, JC [1 ]
机构
[1] INST PASTEUR,SERV PHYS MED,PARIS,FRANCE
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1995年 / 32卷 / 03期
关键词
RADIOTHERAPY; QUALITY CONTROL; INHOMOGENEITIES; RADIOTHERAPY TREATMENT PLANNING;
D O I
10.1016/0360-3016(94)00474-Y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This quality control program has been carried out under the auspices of S.F.P.H. (Societe Francaise des Physiciens d'Hopital), to evaluate the performances of radiotherapy treatment planning systems (RTPS) used by different institutions, The aim of this Quality Assurance Programme was: (a) to set up a methodology to assess globally the capability of a given system to perform inhomogeneity corrections in the irradiated medium with external photon beams; (b) to analyze the limitations of the algorithms presently used and especially the two-dimensional (2D) dose calculation possibilities; (c) to check, on a number of systems in clinical use, the validity of the method and the variation of the results as compared to measurements used as reference. Methods and Materials: Phantom (lung equivalent material placed into polystyrene) measurements, using cobalt-60 radiation, were carried out by the authors. The phantoms were circulated among the participating institutes to be scanned, and used as input to the treatment planning computer. Results: Ten systems were tested in this study, using seven different inhomogeneity correction algorithms implemented in nine different TPS; four of these algorithms are used in a pixel by pixel basis and five of them in a contour basis. Significant discrepancies or inconsistencies have been observed even for sophisticated models supposed to be mostly accurate. Conclusion: The proposed tests and the experimental data provided are very useful as part of a quality-control program. They should be included in the initial extensive validation of TPS before starting clinical use, and should be repeated at regular intervals and at each updating of the program. They have the merit of including the whole procedure, from patient data acquisition to dose distribution printout.
引用
收藏
页码:847 / 858
页数:12
相关论文
共 37 条
  • [11] Discrete and continuous description of a three dimensional scene for quality control of radiotherapy treatment planning systems
    Denis, Eloise
    Guedon, JeanPierre
    Beaumont, Stephane
    Normand, Nicolas
    Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3, 2006, 6142 : 14255 - 14255
  • [12] MECHANICAL AND DOSIMETRIC QUALITY-CONTROL FOR COMPUTER-CONTROLLED RADIOTHERAPY TREATMENT EQUIPMENT
    THOMPSON, AV
    LAM, KL
    BALTER, JM
    MCSHAN, DL
    MARTEL, MK
    WEAVER, TA
    FRAASS, BA
    TENHAKEN, RK
    MEDICAL PHYSICS, 1995, 22 (05) : 563 - 566
  • [13] Contributions to the Normalization of the Control Systems Used for Quality Control of the Interior Body Parts Used in Automotive Industry
    Orzan, Iulian
    Buzatu, Constantin
    ENGINEERING SOLUTIONS AND TECHNOLOGIES IN MANUFACTURING, 2014, 657 : 956 - 960
  • [14] Quality control of rain data used for urban runoff systems
    Jorgensen, HK
    Rosenorn, S
    Madsen, H
    Mikkelsen, PS
    WATER SCIENCE AND TECHNOLOGY, 1998, 37 (11) : 113 - 120
  • [15] Two quality control procedures on radiotherapy beam calibration and treatment planning system implementation
    Piermattei, A
    Azario, L
    delle Canne, S
    Fidanzio, A
    Palazzoni, G
    TUMORI, 1998, 84 (02) : 150 - 154
  • [16] SPATIAL AND TEMPORAL RESPONSE CHARACTERISTICS OF IONIZATION CHAMBERS USED IN DIAGNOSTIC-RADIOLOGY FOR EXPOSURE MEASUREMENTS AND QUALITY-CONTROL
    KOFLER, JM
    GRAY, JE
    DALY, TR
    HEALTH PHYSICS, 1994, 67 (06): : 661 - 667
  • [17] Intercomparison of Treatment Planning Systems (TPS) used in Radiotherapy: Progress report of the TPS Group of the European Dynarad project
    Panitsa, E
    Rosenwald, JC
    Kappas, C
    PHYSICA MEDICA, 1997, 13 : 139 - 143
  • [18] QUALITY-CONTROL IN THE CONSERVATIVE TREATMENT OF BREAST-CANCER - PATIENT DOSIMETRY USING SILICON DETECTORS
    CIOCCA, M
    LANDONI, L
    ITALIA, C
    MONTANARO, P
    CANESI, P
    VALDAGNI, R
    RADIOTHERAPY AND ONCOLOGY, 1991, 22 (04) : 304 - 307
  • [19] IMAGE QUALITY OF INTRAORAL RADIOGRAPHS USED BY GENERAL-PRACTITIONERS IN PROSTHODONTIC TREATMENT PLANNING
    SVENSON, B
    ERIKSSON, T
    KRONSTROM, M
    PALMQVIST, S
    DENTOMAXILLOFACIAL RADIOLOGY, 1994, 23 (01) : 46 - 48
  • [20] QUALITY-CONTROL PARAMETERS OF MASS-REARED OPIINE PARASITOIDS USED IN AUGMENTATIVE BIOLOGICAL-CONTROL OF TEPHRITID FRUIT-FLIES IN HAWAII
    MESSING, RH
    KLUNGNESS, LM
    PURCELL, M
    WONG, TTY
    BIOLOGICAL CONTROL, 1993, 3 (02) : 140 - 147