Diagnosis of the Doubly-Fed Induction Generator of a Wind Turbine

被引:17
作者
Bennouna, O. [1 ]
Heraud, N. [1 ]
Camblong, H. [2 ]
Rodriguez, M. [3 ]
机构
[1] Univ Corse, SPE CNRS UMR 6134, F-20250 Quartier Grossetti, Corte, France
[2] LIPSI ESTIA, F-64210 Bidart, France
[3] Mondragon Goi Eskola Politeknikoa, F-20500 Arrasate Mondragon, Spain
关键词
D O I
10.1260/030952405775992607
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a method of identifying and estimating gross errors for linear dynamic systems. The method is applied to wind power, in particular the doubly-fed induction generator. Measurements have errors, but it is possible to reduce the effect of such errors on control by exploiting relationships between the different variables of the system. Such analysis is called 'data validation'. Data validation uses a mathematical model, based on equations, to simulate the real dynamic system. An analysis of systematic errors is made using a measurement test. The method has the potential to support the on-line multiparameter data analysis, and hence maintenance, of complex systems, such as wind turbines.
引用
收藏
页码:431 / 447
页数:17
相关论文
共 24 条